510(k) Report

510(k) · Cleared

Cleared

Prime BIOFOAM® Multi-Hole Shells

K201157510(k) TraditionalCleared Aug 24, 2021481-day reviewClass II21 CFR 888.3358

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Microport Orthopedics, Inc. · MBL Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous

Cleared on Aug 24, 2021 as substantially equivalent to K170444 (Microport Orthopedics, Inc., 2017) and 2 other predicates after a 481-day review. Its family tree reaches back 7 generations to 1993.

Decided
Aug 24, 2021
Review
481 days
Class
Class II
Product code
MBL
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K930712 (1993). 21 ancestors in all, the oldest K864626 (1986). No later device cites it as a predicate yet.

  1. Root · 7 generations backK930712 P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc. · 1993
  2. 6 generations backK983014 Summit Acetabular SystemJohnson & Johnson Professionals, Inc. · 1998
  3. 5 generations backK000306 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000 · Recalled
  4. 4 generations backK001534 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000
  5. 3 generations backK071784 Depuy Pinnacle with Gripton Acetabular CupsDePuy Orthopaedics, Inc. · 2007
  6. 2 generations backK090998 Depuy Pinnacle 100 with Gription Acetabular CupsDePuy Orthopaedics, Inc. · 2009
  7. 1 generation backK170444 PROCOTYL® PRIME Acetabular Cup SystemMicroport Orthopedics, Inc. · 2017
  8. This deviceK201157 Prime BIOFOAM® Multi-Hole ShellsMicroport Orthopedics, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K930712P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc.1993—
−6K983014Summit Acetabular SystemJohnson & Johnson Professionals, Inc.1998—
−5K000306Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.20001
−4K001534Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.2000—
−3K071784Depuy Pinnacle with Gripton Acetabular CupsDePuy Orthopaedics, Inc.2007—
−2K090998Depuy Pinnacle 100 with Gription Acetabular CupsDePuy Orthopaedics, Inc.2009—
−1K170444PROCOTYL® PRIME Acetabular Cup SystemMicroport Orthopedics, Inc.2017—
0 (this device)K201157Prime BIOFOAM® Multi-Hole ShellsMicroport Orthopedics, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199420
199530
199610
200010
200410
200510
200610
200710
200910
201210
FIG. 1 — Lineage of K201157, 1993–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MBL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MBL device

  1. #1 K201701 R3 HA Coated Acetabular Shellsscore 1.3 · 5 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170444PROCOTYL® PRIME Acetabular Cup System
Summary page 4
…II Subject Panel and Orthopedics/87/MBL, LPH, LZO Product Code(s): Legally Marketed Devices to which Substantial Equivalence is claimed: Primary Predicate: K170444 Prime Acetabular Cup System MicroPort Orthopedics Inc. Predicate Devices: K122382 DYNASTY® BIOFOAM® Shell…
Microport Orthopedics, Inc.2017—
*K122382Dynasty Biofoam Shell
Summary page 4
…s to which Substantial Equivalence is claimed: Primary Predicate: K170444 Prime Acetabular Cup System MicroPort Orthopedics Inc. Predicate Devices: K122382 DYNASTY® BIOFOAM® Shell MicroPort Orthopedics Inc. K082924 DYNASTY® BIOFOAM® Shell…
Wrightmedicaltechnologyinc2012—
*K082924Dynasty Porous Acetabular Shell, Dynasty Polyethylene Acetabular Liner, Dynasty Metal…
Summary page 4
…Cup System MicroPort Orthopedics Inc. Predicate Devices: K122382 DYNASTY® BIOFOAM® Shell MicroPort Orthopedics Inc. K082924 DYNASTY® BIOFOAM® Shell MicroPort Orthopedics Inc.…
Wrightmedicaltechnologyinc200917

Also cleared against K170444: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 4.2 years on median.
  • 4 of the 21 ancestors have a recall of any class.
  • 7 other devices also cite its predicate K170444.

How does its category compare?

All MBL devices

MBL Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · MBL

1in 2021

2007: 12009: 12010: 12011: 12012: 22016: 12018: 12020: 12021: 1
2007high 2 (2012) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MBL

Too few MBL 510(k)s in any year since 2007 to give a median.

Recalls per year · MBL

1in 2014

2011: 22014: 1
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MBL

41in 2025

2010: 12011: 62012: 32013: 52014: 152015: 552016: 542017: 612018: 1122019: 1722020: 1152021: 1162022: 902023: 782024: 542025: 41
2007high 172 (2019) · low 0 (2007)2025

MAUDE reports naming product code MBL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20091—00
20101—01
20111—26
20122—03
20130—05
20140—115
20150—055
20161—054
20170—061
20181—0112
20190—0172
20201—0115
20211—0116
20220—090
20230—078
20240—054
20250—041
20260—0—

What is it indicated for?

The Prime Acetabular Cup System is intended for use in total hip arthroplasty for reduction or relief of pain and/or improved hip function in skeletally mature patients.

Indications for Use

1) non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusio acetabuli, and painful hip dysplasia;

2) inflammatory degenerative joint disease such as rheumatoid arthritis;

3) correction of functional deformity; and,

4) revision procedures where other treatments or devices have failed.

Shells with BIOFOAM® coating are intended only for uncemented arthroplasty.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K201157: Prime BIOFOAM® Multi-Hole Shells.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K201157

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026