Prime and DYNASTY® Additive Manufacturing Shells

K202705510(k) TraditionalCleared Aug 20, 2021338-day reviewClass II21 CFR 888.3358

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Microport Orthopedics, Inc. · OQG Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented

Cleared on Aug 20, 2021 as substantially equivalent to K170444 (Microport Orthopedics, Inc., 2017) and 2 other predicates after a 338-day review. Its family tree reaches back 7 generations to 1993.

Decided
Aug 20, 2021
Review
338 days
Class
Class II
Product code
OQG
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K930712 (1993). 21 ancestors in all, the oldest K864626 (1986). No later device cites it as a predicate yet.

  1. Root · 7 generations backK930712 P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc. · 1993
  2. 6 generations backK983014 Summit Acetabular SystemJohnson & Johnson Professionals, Inc. · 1998
  3. 5 generations backK000306 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000 · Recalled
  4. 4 generations backK001534 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000
  5. 3 generations backK071784 Depuy Pinnacle with Gripton Acetabular CupsDePuy Orthopaedics, Inc. · 2007
  6. 2 generations backK090998 Depuy Pinnacle 100 with Gription Acetabular CupsDePuy Orthopaedics, Inc. · 2009
  7. 1 generation backK170444 PROCOTYL® PRIME Acetabular Cup SystemMicroport Orthopedics, Inc. · 2017
  8. This deviceK202705 Prime and DYNASTY® Additive Manufacturing ShellsMicroport Orthopedics, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K930712P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc.1993—
−6K983014Summit Acetabular SystemJohnson & Johnson Professionals, Inc.1998—
−5K000306Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.20001
−4K001534Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.2000—
−3K071784Depuy Pinnacle with Gripton Acetabular CupsDePuy Orthopaedics, Inc.2007—
−2K090998Depuy Pinnacle 100 with Gription Acetabular CupsDePuy Orthopaedics, Inc.2009—
−1K170444PROCOTYL® PRIME Acetabular Cup SystemMicroport Orthopedics, Inc.2017—
0 (this device)K202705Prime and DYNASTY® Additive Manufacturing ShellsMicroport Orthopedics, Inc.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199420
199530
199610
200010
200410
200510
200610
200710
200910
201210
FIG. 1 — Lineage of K202705, 1993–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OQG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OQG device

  1. #1 K200328 Tesera Trabecular Technologies (T3) Acetabular…score 4.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170444PROCOTYL® PRIME Acetabular Cup System
Summary page 4
…Class II Subject Product Code and Panel Code: Orthopedics/87/OQG, OQI, LPH, LZO Primary Predicate: Prime BIOFOAM® Acetabular Shells (K170444) Additional Predicates: DYNASTY® Acetabular System (K082924)…
Microport Orthopedics, Inc.2017—
*K082924Dynasty Porous Acetabular Shell, Dynasty Polyethylene Acetabular Liner, Dynasty Metal…
Summary page 4
…H, LZO Primary Predicate: Prime BIOFOAM® Acetabular Shells (K170444) Additional Predicates: DYNASTY® Acetabular System (K082924) DYNASTY® BIOFOAM® Shell (K122382) Reference Devices: BIOF…
Wrightmedicaltechnologyinc200917
*K122382Dynasty Biofoam Shell
Summary page 4
…Shells (K170444) Additional Predicates: DYNASTY® Acetabular System (K082924) DYNASTY® BIOFOAM® Shell (K122382) Reference Devices: BIOFOAM® Additive Manufacturing (K170288)…
Wrightmedicaltechnologyinc2012—
†K170288BIOFOAM® Additive Manufacturing (BIOFOAM® AM), ADVANCE® BIOFOAM® Tibial Base, EVOLUTION®…Microport Orthopedics, Inc.2017—

Also cleared against K170444: 7 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 4 companies; a new generation was cleared every 4.2 years on median.
  • 4 of the 21 ancestors have a recall of any class.
  • 7 other devices also cite its predicate K170444.

How does its category compare?

All OQG devices

OQG Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · OQG

2in 2021

2011: 12012: 52013: 32014: 32015: 12017: 32020: 22021: 2
2007high 5 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OQG

99in 2017

2012: 144 days median2013: 280 days median2014: 99 days median2017: 99 days median
2007high 280 (2013) · low 99 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OQG

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OQG

16in 2025

2013: 52014: 312015: 522016: 452017: 272018: 432019: 1042020: 1782021: 882022: 322023: 182024: 202025: 16
2007high 178 (2020) · low 0 (2007)2025

MAUDE reports naming product code OQG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20111—00
2012514400
2013328015
2014399031
20151—052
20160—045
2017399027
20180—043
20190—0104
20202—0178
20212—088
20220—032
20230—018
20240—020
20250—016
20260—0—

What is it indicated for?

The Prime and DYNASTY® Additive Manufacturing Shells are intended for use in total hip arthroplasty for reduction or relief of pain and/or improved hip function in skeletally mature patients.

Indications for Use

1) non-inflammatory degenerative joint disease such as osteoarthritis, avascular necrosis, ankylosis, protrusio acetabuli, and painful hip dysplasia;

2) inflammatory degenerative joint disease such as rheumatoid arthritis;

3) correction of functional deformity; and,

4) revision procedures where other treatments or devices have failed.

Shells with BIOFOAM® metal foam coating are intended only for uncemented arthroplasty.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K202705: Prime and DYNASTY® Additive Manufacturing Shells.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202705

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026