510(k) · Cleared
ClearedPF4 Enhanced assay
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Immucor Gti Diagnostics, Inc. · LCO Platelet Factor 4 Radioimmunoassay
Cleared on Sep 11, 2020 as substantially equivalent to K053559 (Genetic Testing Institute, 2006) after a 92-day review. Its family tree reaches back 2 generations to 1999.
- Decided
- Sep 11, 2020
- Review
- 92 days
- Class
- Class II
- Product code
- LCO
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K983379 (1999). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LCO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LCO device
- #1 K243374 HemosIL CL HIT-IgG (PF4-H)score 9.7 · 4 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K053559 | PF4 Enhanced Solid Phase ElisaSummary page 4…LCO Establishment Registration Number: 2183608 4. Name of Predicate Device for Claiming Equivalence PF4 Enhanced Assay (K053559) 5. Description of Device PF4 Enhanced Assay is an Enzyme Linked Immunosorbent Assay (ELISA). The PF4 Enhanced EL… | 2006 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 21 years and passes through 2 companies; a new generation was cleared every 14.6 years on median.
- 1 of the 2 ancestors has a recall of any class.
- 2 other devices also cite its predicate K053559.
How does its category compare?
All LCO devicesLCO Platelet Factor 4 Radioimmunoassay: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.
FDA decisions per year · LCO
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LCO
Too few LCO 510(k)s in any year since 2007 to give a median.
Recalls per year · LCO
3so far in 2026, the most since 2007
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · LCO
11in 2025
MAUDE reports naming product code LCO, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 2 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 1 | 0 |
| 2014 | 0 | — | 1 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 1 | — | 0 | 2 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 0 | — | 0 | 4 |
| 2020 | 2 | — | 0 | 1 |
| 2021 | 0 | — | 0 | 0 |
| 2022 | 0 | — | 0 | 0 |
| 2023 | 0 | — | 0 | 0 |
| 2024 | 0 | — | 0 | 2 |
| 2025 | 1 | — | 0 | 11 |
| 2026 | 0 | — | 3 (2) | — |
What is it indicated for?
PF4 Enhanced assay is designed as a solid phase enzyme linked immunosorbent assay (ELISA). The product is intended to be used as an in vitro diagnostic kit by hematology, coagulation, or other pathology laboratories to assist in screening patient samples, 3.2% sodium citrate (plasma) or without anticoagulant (serum), for the presence of heparin associated commonly found in patients with heparin induced thrombocytopenia (HIT) or thrombosis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K201570 · printed Nov 6, 2026
Cite this page
510(k) Report. “K201570: PF4 Enhanced assay.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K201570
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026