510(k) Report

510(k) · Cleared

Cleared

Materialise PKA Guide System

K202207510(k) TraditionalCleared Oct 2, 202057-day reviewClass II21 CFR 888.3520

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Materialise NV · HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer

Cleared on Oct 2, 2020 as substantially equivalent to K173970 (Materialise NV, 2018) after a 57-day review. Its family tree reaches back 11 generations to 1993.

Decided
Oct 2, 2020
Review
57 days
Class
Class II
Product code
HSX
Recalls
None
Predicates
1

Its longest line of descent runs back 11 generations to K924630 (1993). 23 ancestors in all, the oldest K880155 (1988). No later device cites it as a predicate yet.

  1. Root · 11 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 7 generations between
  3. 3 generations backK162273 Materialise TKA Guide SystemMaterialise NV · 2016
  4. 2 generations backK172650 Materialise PKA Guide SystemMaterialise NV · 2017
  5. 1 generation backK173970 Materialise PKA Guide SystemMaterialise NV · 2018
  6. This deviceK202207 Materialise PKA Guide SystemMaterialise NV · 2020
Show all 11 generations
  1. Root · 11 generations backK924630 Surgicad (TM) View (TM)Surgicad Corp. · 1993
  2. 10 generations backK970617 CT-Modeller SystemMaterialise NV · 1997
  3. 9 generations backK033849 Simplant SystemMaterialise NV · 2004
  4. 8 generations backK073449 SurgicaseMaterialise NV · 2008
  5. 7 generations backK102795 Signature Planner; Signature GuidesMaterialise NV · 2011 · Recalled
  6. 6 generations backK121640 Zimmer Patient Specific Instruments SystemMaterialise NV · 2012 · Recalled
  7. 5 generations backK133162 Zimmer Patient Specific Instruments System, Zimmer Patient Specific…Materialise NV · 2014
  8. 4 generations backK150928 Materialise TKA Guide System, Materialise TKA Planner, Materialise…Materialise NV · 2015
  9. 3 generations backK162273 Materialise TKA Guide SystemMaterialise NV · 2016
  10. 2 generations backK172650 Materialise PKA Guide SystemMaterialise NV · 2017
  11. 1 generation backK173970 Materialise PKA Guide SystemMaterialise NV · 2018
  12. This deviceK202207 Materialise PKA Guide SystemMaterialise NV · 2020
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−11K924630Surgicad (TM) View (TM)Surgicad Corp.1993—
−10K970617CT-Modeller SystemMaterialise NV1997—
−9K033849Simplant SystemMaterialise NV2004—
−8K073449SurgicaseMaterialise NV2008—
−7K102795Signature Planner; Signature GuidesMaterialise NV20114
−6K121640Zimmer Patient Specific Instruments SystemMaterialise NV20121
−5K133162Zimmer Patient Specific Instruments System, Zimmer Patient Specific…Materialise NV2014—
−4K150928Materialise TKA Guide System, Materialise TKA Planner, Materialise TKA GuidesMaterialise NV2015—
−3K162273Materialise TKA Guide SystemMaterialise NV2016—
−2K172650Materialise PKA Guide SystemMaterialise NV2017—
−1K173970Materialise PKA Guide SystemMaterialise NV2018—
0 (this device)K202207Materialise PKA Guide SystemMaterialise NV2020—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199310
200110
200410
200810
201010
201120
201220
201410
201810
FIG. 1 — Lineage of K202207, 1993–2020Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HSX device

  1. #1 K261609 Freedom Partial Knee Systemscore 15.1 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173970Materialise PKA Guide System
Summary page 6
…nce is claimed: Trade or proprietary or model name Materialise PKA Guide System 510(k) number K173970 Decision date July 6, 2018 Classification product code…
Materialise NV2018—

Also cleared against K173970: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 2 companies; a new generation was cleared every 1.8 years on median.
  • 7 of the 23 ancestors have a recall of any class.
  • 1 other device also cites its predicate K173970.

How does its category compare?

All HSX devices

HSX Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2020, this device’s year, is highlighted.

FDA decisions per year · HSX

4in 2025

2007: 62008: 42009: 22010: 32011: 12012: 52013: 22015: 12016: 32017: 52018: 22019: 72020: 42021: 72022: 22023: 12024: 42025: 42026 (partial year): 2
2007high 7 (2019) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HSX

59in 2025

2007: 33 days median2008: 102 days median2010: 74 days median2012: 88 days median2016: 147 days median2017: 160 days median2019: 90 days median2020: 40 days median2021: 81 days median2024: 133 days median2025: 59 days median
2007high 160 (2017) · low 33 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HSX

2in 2020

2009: 492013: 12016: 12017: 42020: 2
2007high 49 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HSX

175in 2025

2007: 62008: 42009: 212010: 582011: 1142012: 832013: 792014: 662015: 572016: 1072017: 1132018: 1592019: 1772020: 2732021: 2402022: 2572023: 2312024: 1722025: 175
2007high 273 (2020) · low 4 (2008)2025

MAUDE reports naming product code HSX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200763306
2008410204
20092—4921
2010374058
20111—0114
2012588083
20132—179
20140—066
20151—057
201631471107
201751604113
20182—0159
20197900177
20204402273
20217810240
20222—0257
20231—0231
202441330172
20254590175
20262—0—

What is it indicated for?

Hardware • Guides The Materialise PKA Guides are intended to be used as a surgical instrument to assist in the intra-operative positioning of Partial Knee Replacement components and in guiding the marking of bone before cutting and to guide cutting of the bone. The Materialise PKA Guides must be used in conjunction with the compatible prostheses families only: ZUK UNI, JOURNEY™ UNI, JOURNEY II UNI, JZ (Hybrid) UNI knee systems, Vanguard™ M…

Read the full statement (289 words)

Hardware

• Guides

The Materialise PKA Guides are intended to be used as a surgical instrument to assist in the intra-operative positioning of Partial Knee Replacement components and in guiding the marking of bone before cutting and to guide cutting of the bone.

The Materialise PKA Guides must be used in conjunction with the compatible prostheses families only: ZUK UNI, JOURNEY™ UNI, JOURNEY II UNI, JZ (Hybrid) UNI knee systems, Vanguard™ M Unicompartmental Knee System, Oxford® Partial Knee System and Persona® Partial Knee System.

The Zimmer Biomet Patient Specific Instruments are compatible for use with the Oxford® Partial Knee System as approved in P010014.

The Materialise PKA Guides are intended for single use only.

• Models

The Materialise PKA Models are intended to be used as a surgical instrument to assist in the intra-operative positioning of Partial Knee Replacement components.

The Materialise PKA Models must be used in conjunction with the compatible prostheses families only: ZUK UNI, JOURNEY™ UNI, JOURNEY II UNI, JZ (Hybrid) UNI knee systems, Vanguard™ M Unicompartmental Knee System, Oxford® Partial Knee System and Persona® Partial Knee System.

The Zimmer Biomet Patient Specific Instruments are compatible for use with the Oxford® Partial Knee System as approved in P010014.

The Materialise PKA Models are intended for single use only.

Software

The SurgiCase Knee Planner is intended to be used as a pre-surgical planner for knee orthopedic surgery. The software is used to pre-operatively plan the positioning of knee components. The SurgiCase Knee Planner allows the surgeon to visualize, measure, reconstruct, annotate and edit pre-surgical plan data. The software leads to the generation of a surgery report along with a pre-surgical plan data file which is used as input data to design the Materialise Knee Guides and Models.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K202207: Materialise PKA Guide System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K202207

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026