510(k) Report

510(k) · Cleared

Cleared

CATSmart, Automated Blood Processing Autotransfusion System

K210089510(k) SpecialCleared Feb 11, 202129-day reviewClass II21 CFR 868.5830

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fresenius Kabi AG · CAC Apparatus, Autotransfusion

Cleared on Feb 11, 2021 as substantially equivalent to K192368 (Fresenius Kabi AG, 2019) after a 29-day review. Its family tree reaches back 3 generations to 1997.

Decided
Feb 11, 2021
Review
29 days
Class
Class II
Product code
CAC
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K971274 (1997). No later device cites it as a predicate yet.

  1. Root · 3 generations backK971274 C.a.T.S Continuous Autotransfusion System, AT1 Autotransfusion Set…Fresenius AG · 1997
  2. 2 generations backK180831 CATSmartFresenius Kabi AG · 2018 · Recalled
  3. 1 generation backK192368 CATSmartFresenius Kabi AG · 2019
  4. This deviceK210089 CATSmart, Automated Blood Processing Autotransfusion SystemFresenius Kabi AG · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K971274C.a.T.S Continuous Autotransfusion System, AT1 Autotransfusion Set, PSQ SetFresenius AG1997—
−2K180831CATSmartFresenius Kabi AG20181
−1K192368CATSmartFresenius Kabi AG2019—
0 (this device)K210089CATSmart, Automated Blood Processing Autotransfusion SystemFresenius Kabi AG2021—
FIG. 1 — Lineage of K210089, 1997–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAC device

  1. #1 K240426 Aventus Clot Management Systemscore 11.2 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192368CATSmart
Summary page 5
…www.fresenius-kabi.us Legally Marketed Device Under Which Substantial Equivalence is Being Claimed 510(k) Number K192368 Device Name CATSmart Common Name Automated Blood Processing Autotransfusion System Classification…
Fresenius Kabi AG2019—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 2 companies; a new generation was cleared every 1.4 years on median.
  • 1 of the 3 ancestors has a recall of any class.

How does its category compare?

All CAC devices

CAC Apparatus, Autotransfusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · CAC

3in 2024

2008: 12010: 42011: 22012: 32013: 12014: 32016: 22017: 12018: 22019: 12020: 12021: 42022: 12023: 22024: 3
2007high 4 (2010) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAC

91in 2024

2010: 123 days median2012: 90 days median2014: 269 days median2021: 155 days median2024: 91 days median
2007high 269 (2014) · low 90 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CAC

7in 2023

2007: 12008: 52009: 252010: 32011: 32013: 92017: 22018: 22019: 232023: 7, 2 Class I
2007high 25 (2009) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · CAC

128in 2025

2007: 352008: 122009: 682010: 1152011: 9392012: 2492013: 1532014: 902015: 872016: 732017: 882018: 872019: 642020: 1082021: 732022: 652023: 392024: 1292025: 128
2007high 939 (2011) · low 12 (2008)2025

MAUDE reports naming product code CAC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—135
20081—512
20090—2568
201041233115
20112—3939
20123900249
20131—9153
20143269090
20150—087
20162—073
20171—288
20182—287
20191—2364
20201—0108
20214155073
20221—065
20232—7 (2)39
20243910129
20250—0128
20260—0—

What is it indicated for?

The CATSmart System by Fresenius Kabi is an autotransfusion device indicated for the processing of autologous shed blood collected intraoperatively and postoperatively to obtain washed packed red blood cells for reinfusion. Additionally, it can be used for perioperative separation of blood into Packed Red Cells (PRC), Plasma (PLS) and Platelet Rich Plasma (PRP).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K210089: CATSmart, Automated Blood Processing Autotransfusion System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210089

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026