ClearedAgilia VP Infusion System, Agilia VP MC WIFI Infusion Pump, Volumat Lines Administration Sets, Agilia Link, Agilia Duo
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fresenius Kabi AG · FRN Pump, Infusion
Cleared on Mar 1, 2022 as substantially equivalent to K121613 (Fresenius Kabi AG, 2013) after a 413-day review. Its family tree reaches back 6 generations to 1990. 6 of the 24 devices in its family, counting itself, have a Class I recall.
- Decided
- Mar 1, 2022
- Review
- 413 days
- Class
- Class II
- Product code
- FRN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 6 generations to K904518 (1990). 23 ancestors in all, the oldest K820133 (1982). No later device cites it as a predicate yet. 6 of the 24 devices in this family, counting this one, have a Class I recall.
- Root · 6 generations backK904518 Volumetric Infusion PumpKendall Mcgaw Laboratories, Inc. · 1990 · Recalled
- 5 generations backK994375 Horizon LightB.Braun Medical, Inc. · 2000 · Recalled (Class I)
- 4 generations backK023189 Vista Basic with FM SystemB.Braun Medical, Inc. · 2003
- 3 generations backK062700 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · Recalled (Class I)
- 2 generations backK083689 Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · Recalled (Class I)
- 1 generation backK121613 Agilia Infusion SystemFresenius Kabi AG · 2013 · Recalled (Class I)
- This deviceK210073 Agilia VP Infusion System, Agilia VP MC WIFI Infusion Pump, Volumat…Fresenius Kabi AG · 2022
Class I recalls in this family
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −6 | K904518 | Volumetric Infusion Pump | Kendall Mcgaw Laboratories, Inc. | 1990 | 37 |
| −5 | K994375 | Horizon Light | B.Braun Medical, Inc. | 2000 | Class I |
| −4 | K023189 | Vista Basic with FM System | B.Braun Medical, Inc. | 2003 | — |
| −3 | K062700 | Infusomat Space Volumetric Infusion Pump System | B.Braun Medical, Inc. | 2006 | Class I |
| −2 | K083689 | Infusomat Space Volumetric Infusion Pump System | B.Braun Medical, Inc. | 2009 | Class I |
| −1 | K121613 | Agilia Infusion System | Fresenius Kabi AG | 2013 | Class I |
| 0 (this device) | K210073 | Agilia VP Infusion System, Agilia VP MC WIFI Infusion Pump, Volumat Lines… | Fresenius Kabi AG | 2022 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1982 | 1 | 0 |
| 1984 | 2 | 0 |
| 1986 | 1 | 0 |
| 1989 | 1 | 0 |
| 1991 | 1 | 0 |
| 1992 | 2 | 0 |
| 1993 | 1 | 0 |
| 1994 | 3 | 0 |
| 1995 | 1 | 1 |
| 1997 | 1 | 0 |
| 2001 | 1 | 1 |
| 2003 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
6 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRN device
- #1 K253703 RemunityPRO+ Pump for Remodulin®…score 12.6 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K121613 | Agilia Infusion SystemSummary page 5…II Infusion pump accessories 80 FPA sets Legally Marketed Device Under Which Substantial Equivalence is Being Claimed Agilia Infusion System (K121613) Device Description The Agilia VP Infusion System includes the Agilia VP MC WiFi Volumetric Infusion Pump, which is a programma… | 2013 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (6 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K121613Agilia Infusion SystemFresenius Kabi AG · 2013 · Direct predicate · ◆ on the line of descent in FIG. 11 Class I recall
- K083689Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2009 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall
- K062700Infusomat Space Volumetric Infusion Pump SystemB.Braun Medical, Inc. · 2006 · 2 generations back · ◆ on the line of descent in FIG. 11 Class I recall
- K011975Horizon Outlook with DosecomB.Braun Medical, Inc. · 2001 · 3 generations back · ◆ in the 2001 ancestors bar of FIG. 11 Class I recall
- K950419The Imed Orion Infusion Pump and Administration SetsImed Corp. · 1995 · 3 generations back · ◆ in the 1995 ancestors bar of FIG. 14 Class I recalls
- K994375Horizon LightB.Braun Medical, Inc. · 2000 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall
Nearest 5 of 6; all are on the web page.
What does this lineage say?
- The line of descent spans 32 years and passes through 3 companies; a new generation was cleared every 3.8 years on median.
- 14 of the 23 ancestors have a recall of any class; 6 have a Class I recall.
- 1 other device also cites its predicate K121613.
How does its category compare?
All FRN devicesFRN Pump, Infusion: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · FRN
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRN
172in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRN
7in 2025
Class I (37 since 2007) Class II/III not classified
Adverse event reports per year · FRN
52,792in 2025
MAUDE reports naming product code FRN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 102 | 15 | 1,086 |
| 2008 | 8 | 89 | 24 | 8,261 |
| 2009 | 9 | 66 | 102 | 1,952 |
| 2010 | 3 | 93 | 37 | 6,133 |
| 2011 | 3 | 103 | 69 | 41,367 |
| 2012 | 4 | 217 | 42 (2) | 15,482 |
| 2013 | 6 | 312 | 22 (3) | 40,082 |
| 2014 | 6 | 172 | 4 (3) | 94,180 |
| 2015 | 3 | 232 | 5 | 26,742 |
| 2016 | 3 | 301 | 7 (1) | 16,560 |
| 2017 | 3 | 305 | 13 | 12,060 |
| 2018 | 3 | 267 | 1 | 16,591 |
| 2019 | 2 | — | 18 (1) | 15,850 |
| 2020 | 1 | — | 16 (5) | 94,186 |
| 2021 | 2 | — | 3 (2) | 199,342 |
| 2022 | 6 | 268 | 2 | 888,020 |
| 2023 | 7 | 265 | 16 (10) | 165,838 |
| 2024 | 5 | 103 | 9 (4) | 57,730 |
| 2025 | 8 | 172 | 7 (4) | 52,792 |
| 2026 | 2 | — | 11 (2) | — |
What is it indicated for?
The Agilia VP Infusion System is intended for adult and pediatric care for the intermittent or continuous delivery of parenteral fluids, medications, blood and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, subcutaneous and intraosseous using dedicated administration sets. The Agilia VP Infusion System is also intended for neonatal care for the…
Read the full statement (107 words)
The Agilia VP Infusion System is intended for adult and pediatric care for the intermittent or continuous delivery of parenteral fluids, medications, blood and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, subcutaneous and intraosseous using dedicated administration sets.
The Agilia VP Infusion System is also intended for neonatal care for the intermittent or continuous delivery of parenteral fluids for hydration and nutrition, blood and blood derivatives through clinically accepted parenteral routes of administration. These routes of administration include intravenous, intra-arterial, and subcutaneous using dedicated administration sets.
It is intended for use by trained healthcare professionals in healthcare facilities.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K210073 · printed Nov 6, 2026
Cite this page
510(k) Report. “K210073: Agilia VP Infusion System, Agilia VP MC WIFI Infusion Pump, Volumat Lines Administration Sets, Agilia Link, Agilia Duo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210073
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026