K210279510(k) TraditionalCleared Oct 29, 2021270-day reviewClass II21 CFR 880.6880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Enbio Group AG · FLE Sterilizer, Steam

Cleared on Oct 29, 2021 as substantially equivalent to K190062 (Scican, Ltd., 2019) after a 270-day review. Its family tree reaches back 1 generation to 2019. 3 later devices descend from it.

Decided
Oct 29, 2021
Review
270 days
Class
Class II
Product code
FLE
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K190062 (2019). 3 later devices descend from it, 2 citing it directly.

Descendants, by year cleared 2025: 1 descendant cleared2022: 1 descendant cleared2026: 1 descendant clearedK190062 · STATCLAVE G4 Chamber Autoclave · Scican, Ltd. · 2019 · recalled201620182020202220242026
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 1 descendant K190062 · STATCLAVE G4 Chamber Autoclave · Scican, Ltd. · 2019 · recalled0
  1. Root · 1 generation backK190062 STATCLAVE G4 Chamber AutoclaveScican, Ltd. · 2019 · Recalled
  2. This deviceK210279 Enbio SEnbio Group AG · 2021
  3. Descendant · cites it directly · 1 of its ownK213991 Enbio SEnbio Group AG · 2022
  4. Descendant · 2 generations on · 0 of its ownK260254 Enbio PROEnbio Group AG · 2026
  5. Descendant · cites it directly · 0 of its ownK250164 Cassette Autoclave (ACA5)Guangzhou Ajax Medical Equipment Co., Ltd. · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K213991Enbio SEnbio Group AG · 2022 · cites it directly1descendant
  • K260254Enbio PROEnbio Group AG · 2026 · 2 generations on0descendants
  • K250164Cassette Autoclave (ACA5)Guangzhou Ajax Medical Equipment Co., Ltd. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K190062STATCLAVE G4 Chamber AutoclaveScican, Ltd.20191
0 (this device)K210279Enbio SEnbio Group AG2021—
+1K213991Enbio SEnbio Group AG2022—
+2K260254Enbio PROEnbio Group AG2026—
+1K250164Cassette Autoclave (ACA5)Guangzhou Ajax Medical Equipment Co., Ltd.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202510
202610
FIG. 1 — Lineage of K210279, 2019–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K190062STATCLAVE G4 Chamber Autoclave
Summary page 4
…FLE Regulation Number 21 CFR 880.6880 Review Panel General Hospital 3. Predicate Device Statclave G4 Chamber Autoclave (K190062) 4. Device Description The Enbio S is an air-removal (pre-vacuum) table-top steam sterilizer intended for use by a…
Scican, Ltd.20191

What descends from it? (3)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K213991Enbio SEnbio Group AG20221
K250164Cassette Autoclave (ACA5)Guangzhou Ajax Medical Equipment Co., Ltd.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K213991 (Enbio Group AG, 2022) has gone furthest, with 1 descendant of its own.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The Enbio S is an air-removal (pre-vacuum) table-top steam sterilizer intended for use by a health care provider to sterilize medical products by means of pressurized steam. It is suitable for the sterilization of dental and medical instruments that are validated to be sterilized by steam. The Enbio S has not been designed to sterilize liquid loads, bio-medical waste or materials not compatible with steam sterilization. The processing of such loads may result in incomplete sterilization and/or damage to the autoclave.

Please refer to the table below for program name, load description, sterilization temperature, exposure time, drying time and maximum load.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K210279: Enbio S.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210279

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026