510(k) Report

510(k) · Cleared

Recalled · Class I · 2023

CereLink ICP Monitor

K210993510(k) SpecialCleared Apr 30, 202128-day reviewClass II21 CFR 882.1620Recalls 2 (2 Class I)

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Lifesciences Production Corporation · GWM Device, Monitoring, Intracranial Pressure

Cleared on Apr 30, 2021 as substantially equivalent to K183406 (Integra Lifesciences Corp., 2019) after a 28-day review. Its family tree reaches back 1 generation to 2019. 2 of the 3 devices in its family, counting itself, have a Class I recall. 1 later device descends from it. It has been recalled 2 times, including 2 Class I recalls.

Decided
Apr 30, 2021
Review
28 days
Class
Class II
Product code
GWM
Recalls
2 (2 Class I)
Predicates
1

Its longest line of descent runs back 1 generation to K183406 (2019). 1 later device descends from it, 1 citing it directly. 2 of the 3 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 2024: 1 descendant cleared, 1 with a Class I recall1Reference device: K945585 · Coman (R) CU-11 Model Number 82-6634 · Johnson & Johnson Professionals, Inc. · 1995K183406 · CereLink ICP Monitor, CereLink ICP Extension Cable · Integra Lifesciences Corp. · 2019 · recalled201620182020202220242026
Descendants, by generation 1 generation forward: 1 descendant, 1 with a Class I recall1 K183406 · CereLink ICP Monitor, CereLink ICP Extension Cable · Integra Lifesciences Corp. · 2019 · recalled0
  1. Root · 1 generation backK183406 CereLink ICP Monitor, CereLink ICP Extension CableIntegra Lifesciences Corp. · 2019 · Recalled
  2. This deviceK210993 CereLink ICP MonitorIntegra Lifesciences Production Corporation · 2021
  3. Descendant · cites it directly · 0 of its ownK232890 CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)Integra Lifesciences Production Corporation · 2024 · Recalled (Class I)

Class I recalls in this family

Most influential descendants

Showing 1 of 1 · See all
  • K232890CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)Integra Lifesciences Production Corporation · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K183406CereLink ICP Monitor, CereLink ICP Extension CableIntegra Lifesciences Corp.20191
0 (this device)K210993CereLink ICP MonitorIntegra Lifesciences Production Corporation2021—
+1K232890CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)Integra Lifesciences Production Corporation2024Class I

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202411
FIG. 1 — Lineage of K210993, 2019–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWM device

  1. #1 K252241 Pressio 3 Multi-parameter Neuromonitoring Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K183406CereLink ICP Monitor, CereLink ICP Extension Cable
Summary page 4
…I Product Code OWM Rx or OTC Designation Rx Only (3) Predicate Information Predicate Device CereLink ICP Monitor: K183406 Reference Device Codman ICP Express: K945585 (4) Device Description The CereLink ICP Monitor is indicated for…
Integra Lifesciences Corp.20191
†K945585Coman (R) CU-11 Model Number 82-6634Johnson & Johnson Professionals, Inc.1995—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232890CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845) Class IIntegra Lifesciences Production Corporation20240

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 5, 2023Class IZ-0548-2024Device DesignFirm is expanding the existing recall RES 90457 for the Cerelink, initiated in June 2022, to include all CereLink ICP Extension Cables. The updated corrective action includes a design change to the extension cable to address the "out of…
Jun 22, 2022Class IZ-1395-2022Device DesignIntegra has received complaints associated with ICP readings drifting to -50 mmHg (out-of-range) and may manifest an error message "sensor or extension cable failure!" The firm has found that this is caused by electrical interference from…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K232890CereLink ICP Monitor (826820), CereLink ICP Extension Cable (826845)Integra Lifesciences Production Corporation · 2024 · Cites it directly · ◆ in the 2024 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K232890 (Integra Lifesciences Production Corporation, 2024) has gone furthest, with 0 descendants of its own.

How does its category compare?

All GWM devices

GWM Device, Monitoring, Intracranial Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · GWM

1in 2025

2007: 22008: 22009: 12010: 22011: 32012: 42013: 22014: 22016: 32017: 32018: 12019: 22020: 32021: 22024: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWM

30in 2020

2011: 123 days median2012: 100 days median2016: 192 days median2017: 37 days median2020: 30 days median
2007high 192 (2016) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWM

3in 2025

2008: 12010: 92011: 62012: 12013: 122014: 22019: 12023: 1, 1 Class I2024: 4, 2 Class I2025: 3
2007high 12 (2013) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · GWM

441in 2025

2007: 1262008: 1052009: 1172010: 1042011: 1842012: 1512013: 1202014: 3602015: 4862016: 4192017: 4452018: 3022019: 2602020: 2682021: 2112022: 4242023: 7442024: 6412025: 441
2007high 744 (2023) · low 104 (2010)2025

MAUDE reports naming product code GWM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0126
20082—1105
20091—0117
20102—9104
201131236184
201241001151
20132—12120
20142—2360
20150—0486
201631920419
20173370445
20181—0302
20192—1260
20203300268
20212—0211
20220—0424
20230—1 (1)744
20242—4 (2)641
20251—3441
20261—0—

What is it indicated for?

The ICP Monitor is intended for use as an interface between compatible strain-gauge type pressure transducers and standard physiological pressure monitoring systems. The ICP Monitor is also intended for use as an independent pressure monitor for displaying the mean, systolic and diastolic values of a physiologic pressure waveform in the absence of an external patient monitor.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K210993: CereLink ICP Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K210993

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026