510(k) Report

510(k) · Cleared

Cleared

TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform

K212224510(k) SpecialCleared Sep 20, 202166-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Imperative Care, Inc. · QJP Catheter, Percutaneous, Neurovasculature

Cleared on Sep 20, 2021 as substantially equivalent to K203764 (Imperative Care, Inc., 2021) and 1 other predicate after a 66-day review. Its family tree reaches back 8 generations to 2001. 6 later devices descend from it.

Decided
Sep 20, 2021
Review
66 days
Class
Class II
Product code
QJP
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K010954 (2001). 13 ancestors in all, the oldest K010853 (2001). 6 later devices descend from it, 3 citing it directly.

  1. Root · 8 generations backK010954 Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc. · 2001 · Recalled
  2. 7 generations backK021899 Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc. · 2002 · Recalled
  3. 6 generations backK053491 Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc. · 2006
  4. 5 generations backK070970 Neuron Support Catheter System, Model 5F/6FPenumbra, Inc. · 2007 · Recalled
  5. 4 generations backK082290 Neuron Delivery Catheter 070Penumbra, Inc. · 2008 · Recalled
  6. 3 generations backK111380 Neuron Max SystemPenumbra, Inc. · 2011
  7. 2 generations backK180169 EagleRay Long Sheath, 0.088 ID, 80cm, 90cm, 100cm and 110cm Lengths…Imperative Care, Inc. · 2018
  8. 1 generation backK203764 TracStar Large Distal Platform, ZOOM 88 Large Distal Platform, ZOOM…Imperative Care, Inc. · 2021
  9. This deviceK212224 TracStar LDP Large Distal Platform; Zoom 88 Large Distal PlatformImperative Care, Inc. · 2021
  10. Descendant · cites it directly · 2 of its ownK231168 TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform…Imperative Care, Inc. · 2023
  11. Descendant · 2 generations on · 1 of its ownK240948 TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform…Imperative Care, Inc. · 2024
  12. Descendant · cites it directly · 1 of its ownK230726 CEREGLIDE 92 Intermediate CatheterCerenovus, Inc. · 2023
  13. Descendant · 3 generations on · 0 of its ownK252297 Toro 88 Superbore CatheterToro Neurovascular, Inc. · 2026
  14. Descendant · 2 generations on · 0 of its ownK233982 CEREGLIDE 92 Catheter SystemCerenovus, Inc. · 2024

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2022: 12023: 22024: 22026: 1
2022high 2 (2023) · low 0 (2025)2026

Most influential descendants

Showing 5 of 6 · See all
  • K231168TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform; Zoom 88 Large Distal…Imperative Care, Inc. · 2023 · cites it directly2descendants
  • K240948TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform; Zoom 88 Large Distal…Imperative Care, Inc. · 2024 · 2 generations on1descendant
  • K230726CEREGLIDE 92 Intermediate CatheterCerenovus, Inc. · 2023 · cites it directly1descendant
  • K252297Toro 88 Superbore CatheterToro Neurovascular, Inc. · 2026 · 3 generations on0descendants
  • K233982CEREGLIDE 92 Catheter SystemCerenovus, Inc. · 2024 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K010954Concentric Balloon Guide Catheter, Model 90031Concentric Medical, Inc.20011
−7K021899Concentric Balloon Guide Catheter, Model 90072Concentric Medical, Inc.20021
−6K053491Penumbra Balloon Guide Catheter, Model 7.5FPenumbra, Inc.2006—
−5K070970Neuron Support Catheter System, Model 5F/6FPenumbra, Inc.20071
−4K082290Neuron Delivery Catheter 070Penumbra, Inc.20081
−3K111380Neuron Max SystemPenumbra, Inc.2011—
−2K180169EagleRay Long Sheath, 0.088 ID, 80cm, 90cm, 100cm and 110cm Lengths, EagleRay…Imperative Care, Inc.2018—
−1K203764TracStar Large Distal Platform, ZOOM 88 Large Distal Platform, ZOOM 88-T Large…Imperative Care, Inc.2021—
0 (this device)K212224TracStar LDP Large Distal Platform; Zoom 88 Large Distal PlatformImperative Care, Inc.2021—
+1K231168TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform; Zoom 88…Imperative Care, Inc.2023—
+2K240948TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform; Zoom 88…Imperative Care, Inc.2024—
+1K230726CEREGLIDE 92 Intermediate CatheterCerenovus, Inc.2023—
+3K252297Toro 88 Superbore CatheterToro Neurovascular, Inc.2026—
+2K233982CEREGLIDE 92 Catheter SystemCerenovus, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200810
201110
201510
201610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202320
202420
202610
FIG. 1 — Lineage of K212224, 2001–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QJP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QJP device

  1. #1 K212838 Benchmark Intracranial Access Systemscore 16.9 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K203764TracStar Large Distal Platform, ZOOM 88 Large Distal Platform, ZOOM 88-T Large Distal…
Summary page 4
…JP, DQY Regulation: 21 CFR. 870.1250 Manufacturer: Imperative Care, Inc. 510(k): K203764 Proprietary Name: EagleRay Long Sheath EagleRay Access Catheter…
Imperative Care, Inc.2021—
*K180169EagleRay Long Sheath, 0.088 ID, 80cm, 90cm, 100cm and 110cm Lengths, EagleRay Access…
Summary page 4
…DQY Regulation: 21 CFR. 870.1250 Manufacturer: Imperative Care Inc. 510(k): K180169 D. Device Description: The Imperative Care Large Distal Platform (LDP) Catheters include the TracStar™ LDP Large Distal Pl…
Imperative Care, Inc.2018—

Also cleared against K203764: 2 other devices →

What descends from it? (6)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K231168TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform; Zoom 88 Large Distal…Imperative Care, Inc.20232
K230726CEREGLIDE 92 Intermediate CatheterCerenovus, Inc.20231
K220807Imperative Care Radial 088 Access SystemImperative Care, Inc.20220

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 20 years and passes through 3 companies; a new generation was cleared every 2.6 years on median.
  • 6 of the 13 ancestors have a recall of any class.
  • Of its descendants, K231168 (Imperative Care, Inc., 2023) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K203764.

How does its category compare?

All QJP devices

QJP Catheter, Percutaneous, Neurovasculature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · QJP

22so far in 2026, the most since 2007

2020: 92021: 122022: 142023: 142024: 182025: 142026 (partial year): 22
2007high 22 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QJP

116in 2025

2020: 72 days median2021: 139 days median2022: 206 days median2023: 184 days median2024: 188 days median2025: 116 days median2026 (partial year): 141 days median
2007high 206 (2022) · low 72 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QJP

1in 2024

2024: 1
2007high 1 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QJP

688in 2025

2020: 162021: 292022: 302023: 752024: 1302025: 688
2007high 688 (2025) · low 0 (2007)2025

MAUDE reports naming product code QJP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
2020972016
202112139029
202214206030
202314184075
2024181881130
2025141160688
2026221410—

What is it indicated for?

The TracStar LDP Large Distal Platform is indicated for the introduction of interventional devices into the peripheral, coronary, and neuro vasculature.

The Zoom 88 Large Distal Platform is indicated for the introduction of interventional devices into the peripheral, coronary, and neuro vasculature.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K212224: TracStar LDP Large Distal Platform; Zoom 88 Large Distal Platform.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212224

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026