510(k) · Cleared
ClearedeMurmur Heart AI
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Csd Labs GmbH · DQD Stethoscope, Electronic
Cleared on May 31, 2022 as substantially equivalent to K181988 (Csd Labs GmbH, 2019) after a 76-day review. Its family tree reaches back 12 generations to 1991. 1 later device descends from it.
- Decided
- May 31, 2022
- Review
- 76 days
- Class
- Class II
- Product code
- DQD
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 12 generations to K910772 (1991). 54 ancestors in all, the oldest K771653 (1977). 1 later device descends from it, 1 citing it directly.
- Root · 12 generations backK910772 Propaq 102, 104 and 106Protocol Systems, Inc. · 1991
- 8 generations between
- 3 generations backK121617 SensicardiacDiacoustic Medical (Pty) · 2012
- 2 generations backK131044 Sensicardiac Mobi Diagnostic Heart Murmur ApplicationDiacoustic Medical Devices (Pty), Ltd. · 2013
- 1 generation backK181988 eMurmur IDCsd Labs GmbH · 2019
- This deviceK220766 eMurmur Heart AICsd Labs GmbH · 2022
- Descendant · cites it directly · 0 of its ownK252284 eMurmur Heart AICsd Labs · 2025
Show all 12 generations
- Root · 12 generations backK910772 Propaq 102, 104 and 106Protocol Systems, Inc. · 1991
- 11 generations backK972020 Oscillomate Non-Invasive Blood Pressure MonitorCas Medical Systems, Inc. · 1998
- 10 generations backK980879 Oscillomate Nibp / SP02 Ems MonitorCas Medical Systems, Inc. · 1998
- 9 generations backK982776 9303 Neonatal/Adult Vital Signs MonitorCas Medical Systems, Inc. · 1998
- 8 generations backK013319 Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure…Nonin Medical, Inc. · 2002
- 7 generations backK041156 Avant Digital Pulse Oximetry System, Models 4000, 4001Nonin Medical, Inc. · 2004 · Recalled
- 6 generations backK043359 4100 Patient Oximeter ModuleNonin Medical, Inc. · 2005
- 5 generations backK083309 Zargis Acoustic Cardioscan, Version 9.33Zargis Medical Corp. · 2009
- 4 generations backK110704 SENSIDiacoustic Medical Devices (Pty), Ltd. · 2011
- 3 generations backK121617 SensicardiacDiacoustic Medical (Pty) · 2012
- 2 generations backK131044 Sensicardiac Mobi Diagnostic Heart Murmur ApplicationDiacoustic Medical Devices (Pty), Ltd. · 2013
- 1 generation backK181988 eMurmur IDCsd Labs GmbH · 2019
- This deviceK220766 eMurmur Heart AICsd Labs GmbH · 2022
Most influential descendants
Showing 1 of 1 · See all- K252284eMurmur Heart AICsd Labs · 2025 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −12 | K910772 | Propaq 102, 104 and 106 | Protocol Systems, Inc. | 1991 | — |
| −11 | K972020 | Oscillomate Non-Invasive Blood Pressure Monitor | Cas Medical Systems, Inc. | 1998 | — |
| −10 | K980879 | Oscillomate Nibp / SP02 Ems Monitor | Cas Medical Systems, Inc. | 1998 | — |
| −9 | K982776 | 9303 Neonatal/Adult Vital Signs Monitor | Cas Medical Systems, Inc. | 1998 | — |
| −8 | K013319 | Nonin Model 2120 Pulse Oximeter and Noninvasive Blood Pressure (Nibp) Monitor | Nonin Medical, Inc. | 2002 | — |
| −7 | K041156 | Avant Digital Pulse Oximetry System, Models 4000, 4001 | Nonin Medical, Inc. | 2004 | 1 |
| −6 | K043359 | 4100 Patient Oximeter Module | Nonin Medical, Inc. | 2005 | — |
| −5 | K083309 | Zargis Acoustic Cardioscan, Version 9.33 | Zargis Medical Corp. | 2009 | — |
| −4 | K110704 | SENSI | Diacoustic Medical Devices (Pty), Ltd. | 2011 | — |
| −3 | K121617 | Sensicardiac | Diacoustic Medical (Pty) | 2012 | — |
| −2 | K131044 | Sensicardiac Mobi Diagnostic Heart Murmur Application | Diacoustic Medical Devices (Pty), Ltd. | 2013 | — |
| −1 | K181988 | eMurmur ID | Csd Labs GmbH | 2019 | — |
| 0 (this device) | K220766 | eMurmur Heart AI | Csd Labs GmbH | 2022 | — |
| +1 | K252284 | eMurmur Heart AI | Csd Labs | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1977 | 1 | 0 |
| 1986 | 1 | 0 |
| 1990 | 1 | 0 |
| 1992 | 3 | 0 |
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
| 1995 | 2 | 0 |
| 1996 | 7 | 0 |
| 1997 | 3 | 0 |
| 1998 | 4 | 0 |
| 1999 | 3 | 0 |
| 2000 | 2 | 0 |
| 2001 | 3 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2004 | 3 | 0 |
| 2005 | 2 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DQD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DQD device
- #1 K200776 Eko COREscore 25.2 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K181988 | eMurmur IDSummary page 4…ewing panel: Cardiology PREDICATE DEVICE Company Product 510(k) CSD Labs GmbH eMurmur ID K181988 INDICATIONS FOR USE The ’eMurmur Heart AI’ software is a decision support system in the evaluation of recorded patient heart so… | 2019 |
| † | K083903 | 3M Littmann Electronic Stethoscope, Model 3200 | 2009 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K252284 | eMurmur Heart AI | 2025 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 31 years and passes through 7 companies; a new generation was cleared every 2.4 years on median.
- 2 of the 54 ancestors have a recall of any class.
- Of its descendants, K252284 (Csd Labs, 2025) has gone furthest, with 0 descendants of its own.
- 2 other devices also cite its predicate K181988.
How does its category compare?
All DQD devicesDQD Stethoscope, Electronic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · DQD
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DQD
89in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DQD
No recall names DQD since 2007.
Adverse event reports per year · DQD
1in 2024
MAUDE reports naming product code DQD, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 6 | 161 | 0 | 0 |
| 2010 | 1 | — | 0 | 0 |
| 2011 | 4 | 107 | 0 | 1 |
| 2012 | 2 | — | 0 | 0 |
| 2013 | 5 | 70 | 0 | 1 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 2 | — | 0 | 0 |
| 2016 | 3 | 250 | 0 | 0 |
| 2017 | 4 | 109 | 0 | 0 |
| 2018 | 4 | 131 | 0 | 0 |
| 2019 | 4 | 262 | 0 | 0 |
| 2020 | 6 | 104 | 0 | 0 |
| 2021 | 4 | 137 | 0 | 0 |
| 2022 | 8 | 203 | 0 | 0 |
| 2023 | 10 | 132 | 0 | 0 |
| 2024 | 4 | 153 | 0 | 1 |
| 2025 | 3 | 89 | 0 | 0 |
| 2026 | 6 | 236 | 0 | — |
What is it indicated for?
The ’eMurmur Heart AI’ software is a decision support system in the evaluation of recorded patient heart sounds. The automated analysis by eMurmur Heart AI identifies specific heart sounds that may be present, including S1, S2, physiological heart murmurs, pathological heart murmurs and the absence of a heart murmur.
eMurmur Heart AI is indicated for use in a setting where auscultation would typically be performed by a healthcare provider. It is not intended as a sole means of diagnosis. The heart sound interpretations offered by eMurmur Heart AI are only significant when considered in conjunction with healthcare provider over-read and including all other relevant patient data.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K220766 · printed Nov 6, 2026
Cite this page
510(k) Report. “K220766: eMurmur Heart AI.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220766
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026