510(k) Report

510(k) · Cleared

Cleared

CO2 Mainstream Sensor

K221118510(k) TraditionalCleared Apr 5, 2023352-day reviewClass II21 CFR 868.1400

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Draegerwerk AG & CO Kgaa · CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase

Cleared on Apr 5, 2023 as substantially equivalent to K100941 (Draeger Medical AG & Co. KG, 2010) after a 352-day review. Its family tree reaches back 8 generations to 1991. 3 of the 34 devices in its family, counting itself, have a Class I recall.

Decided
Apr 5, 2023
Review
352 days
Class
Class II
Product code
CCK
Recalls
None
Predicates
1

Its longest line of descent runs back 8 generations to K902859 (1991). 33 ancestors in all, the oldest K902506 (1991). No later device cites it as a predicate yet. 3 of the 34 devices in this family, counting this one, have a Class I recall.

  1. Root · 8 generations backK902859 Servo Ventilator 300Siemens Life Support Systems · 1991 · Recalled
  2. 7 generations backK961687 EVITA 4Drager, Inc. · 1996
  3. 6 generations backK970460 Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · Recalled (Class I)
  4. 5 generations backK984535 Puritan-Bennett 840 Ventilatory System with Bilevel OptionPuritan Bennett Corp. · 1998 · Recalled (Class I)
  5. 4 generations backK022679 RaphaelHamilton Medical AG · 2003 · Recalled
  6. 3 generations backK040574 Galileo GoldHamilton Medical, Inc. · 2004
  7. 2 generations backK051263 Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa · 2005 · Recalled
  8. 1 generation backK100941 Infinity Mcable - Mainstream CO2Draeger Medical AG & Co. KG · 2010
  9. This deviceK221118 CO2 Mainstream SensorDraegerwerk AG & CO Kgaa · 2023

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K902859Servo Ventilator 300Siemens Life Support Systems19913
−7K961687EVITA 4Drager, Inc.1996—
−6K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp.1998Class I
−5K984535Puritan-Bennett 840 Ventilatory System with Bilevel OptionPuritan Bennett Corp.1998Class I
−4K022679RaphaelHamilton Medical AG20033
−3K040574Galileo GoldHamilton Medical, Inc.2004—
−2K051263Evitaxl with Option SmartcareDrager Medical AG & Co. Kgaa20051
−1K100941Infinity Mcable - Mainstream CO2Draeger Medical AG & Co. KG2010—
0 (this device)K221118CO2 Mainstream SensorDraegerwerk AG & CO Kgaa2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199220
199310
199410
199510
199620
199730
199820
199920
200021
200140
200220
200420
FIG. 1 — Lineage of K221118, 1991–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CCK device

  1. #1 K253030 Capnostream™35 Portable Respiratory Monitor…score 15.8 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100941Infinity Mcable - Mainstream CO2
Summary page 4
…Product Code: CCK Class: II Predicate Device: INFINITY MCABLE - MAINSTREAM CO2, K100941 Drägerwerk AG & Co. KGaA is submitting a traditional 510(k) premarket notification for a new device, the CO2 Mainstream Sensor.…
Draeger Medical AG & Co. KG2010—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (3 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K001646Puritan-Bennett 840 Ventilator System with Neomode OptionPuritan Bennett Corp. · 2000 · 4 generations back · ◆ in the 2000 ancestors bar of FIG. 11 Class I recall
  • K984535Puritan-Bennett 840 Ventilatory System with Bilevel OptionPuritan Bennett Corp. · 1998 · 4 generations back · ◆ on the line of descent in FIG. 11 Class I recall
  • K970460Nellcor Puritan Bennett, 840 Ventilator System (Model 840)Puritan Bennett Corp. · 1998 · 5 generations back · ◆ on the line of descent in FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 32 years and passes through 8 companies; a new generation was cleared every 4.8 years on median.
  • 14 of the 33 ancestors have a recall of any class; 3 have a Class I recall.

How does its category compare?

All CCK devices

CCK Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · CCK

3in 2025

2007: 52008: 32009: 32010: 32011: 22012: 72013: 42014: 92015: 52016: 22017: 52018: 62019: 72020: 42021: 42022: 32023: 42024: 32025: 32026 (partial year): 3
2007high 9 (2014) · low 2 (2011)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CCK

169in 2025

2007: 56 days median2008: 248 days median2009: 101 days median2010: 125 days median2012: 150 days median2013: 132 days median2014: 166 days median2015: 105 days median2017: 134 days median2018: 296 days median2019: 261 days median2020: 188 days median2021: 227 days median2022: 226 days median2023: 555 days median2024: 592 days median2025: 169 days median2026 (partial year): 224 days median
2007high 592 (2024) · low 56 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CCK

1in 2022

2008: 12009: 192010: 42011: 142012: 32013: 2, 1 Class I2015: 12018: 52019: 7, 7 Class I2020: 12022: 1
2007high 19 (2009) · low 0 (2007)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · CCK

1,259in 2025

2007: 72008: 202009: 212010: 122011: 182012: 132013: 282014: 512015: 1142016: 882017: 582018: 632019: 1412020: 2,3022021: 2,2722022: 2,4752023: 1,6372024: 1,2162025: 1,259
2007high 2,475 (2022) · low 7 (2007)2025

MAUDE reports naming product code CCK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200755607
20083248120
200931011921
20103125412
20112—1418
20127150313
201341322 (1)28
20149166051
201551051114
20162—088
20175134058
20186296563
201972617 (7)141
2020418812,302
2021422702,272
2022322612,475
2023455501,637
2024359201,216
2025316901,259
202632240—

What is it indicated for?

The CO2 mainstream sensor enables the diagnosis and monitoring of patients by measuring CO2. The use of the medical device is limited to one patient at a time.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K221118: CO2 Mainstream Sensor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K221118

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026