Edwards Lifesciencess, LLC · DYG Catheter, Flow Directed

Cleared on Sep 21, 2023 as substantially equivalent to K160084 (Edwards Lifesciences, LLC, 2016) and 3 other predicates after a 143-day review. Its family tree reaches back 28 generations to 1994. 2 of the 267 devices in its family, counting itself, have a Class I recall. 6 later devices descend from it. It has been recalled 2 times.

Decided
Sep 21, 2023
Review
143 days
Class
Class II
Product code
DYG
Recalls
2
Predicates
4

Its longest line of descent runs back 28 generations to K941811 (1994). 260 ancestors in all, the oldest K810124 (1981). 6 later devices descend from it, 2 citing it directly. 2 of the 267 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 2019: 1 other ancestor2016: 3 other ancestors, 2 with a Class I recall22015: 2 other ancestors2014: 4 other ancestors2005: 5 other ancestors2000: 23 other ancestors1995: 8 other ancestors1994: 4 other ancestors1993: 9 other ancestors1991: 9 other ancestors1989: 3 other ancestors1982: 2 other ancestors1981: 2 other ancestors2018: 3 other ancestors2013: 1 other ancestor2011: 1 other ancestor1990: 7 other ancestors2010: 6 other ancestors2008: 9 other ancestors2007: 2 other ancestors2017: 1 other ancestor2012: 2 other ancestors2006: 9 other ancestors2009: 5 other ancestors2004: 19 other ancestors2003: 9 other ancestors2002: 17 other ancestors2001: 9 other ancestors1998: 16 other ancestors1997: 7 other ancestors1996: 10 other ancestors1985: 3 other ancestors1999: 10 other ancestors1992: 7 other ancestors1988: 2 other ancestors1987: 1 other ancestor1986: 1 other ancestor2024: 1 descendant cleared2025: 4 descendants cleared2026: 1 descendant clearedK941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996×3: 3 generations cleared close together, K981376 (1999), K990125 (1999), K990972 (1999) ×19: 19 generations cleared close together, K013199 (2001), K020531 (2002), K021778 (2002), K023871 (2002), K030038 (2003), K031481 (2003), K032858 (2003), K040304 (2004), K041235 (2004), K042845 (2004), K050141 (2005), K050762 (2005), K051106 (2005), K052801 (2005), K053522 (2006), K060221 (2006), K060541 (2006), K061052 (2006), K062283 (2006) K180881 · HemoSphere Advanced Monitor, HemoSphere Pressure Cable · Edwards Lifesciences, LLC · 2018K190205 · HemoSphere Advanced Monitor, HemoSphere Tissue Oximetry Module · Edwards Lifesciences, LLC · 2019K201446 · HemoSphere Advanced Monitoring Platform, HemoSphere ClearSight Module · Edwards Lifesiences, LLC · 2020 · recalledK221833 · HemoSphere Advanced Monitor, HemoSphere ClearSight Module · Edwards Lifesciences, LLC · 202219801990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors, 1 with a Class I recall12 generations back: 14 other ancestors, 1 with a Class I recall13 generations back: 7 other ancestors4 generations back: 7 other ancestors5 generations back: 10 other ancestors6 generations back: 20 other ancestors7 generations back: 35 other ancestors8 generations back: 60 other ancestors9 generations back: 27 other ancestors10 generations back: 22 other ancestors11 generations back: 18 other ancestors12 generations back: 8 other ancestors13 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 2 descendants K221833 · HemoSphere Advanced Monitor, HemoSphere ClearSight Module · Edwards Lifesciences, LLC · 2022K201446 · HemoSphere Advanced Monitoring Platform, HemoSphere ClearSight Module · Edwards Lifesiences, LLC · 2020 · recalledK190205 · HemoSphere Advanced Monitor, HemoSphere Tissue Oximetry Module · Edwards Lifesciences, LLC · 2019K180881 · HemoSphere Advanced Monitor, HemoSphere Pressure Cable · Edwards Lifesciences, LLC · 2018K062283 · The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90 Intellivue Patient Monitors · Philips Medical Systems North America, Inc. · 2006K061052 · The Philips Intellivue Patient Monitors, Models MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90 · Philips Medical Systems North America, Inc. · 2006K060541 · The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient Monitors · Philips Medizin Systeme Boblingen GmbH · 2006 · recalledK060221 · The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2006K053522 · Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors, Release D.00 · Philips Medizin Systeme Boeblingen GmbH · 2006K052801 · Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 · Philips Medizin Systeme Boeblingen GmbH · 2005K051106 · The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2005K050762 · Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70 and MP90 · Philips Medizin Systeme Boeblingen GmbH · 2005K050141 · The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2005K042845 · The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boblingen GmbH · 2004K041235 · Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient Monitors · Philips Medizin Systeme Boeblingen GmbH · 2004K040304 · Philips Intellivue Patient Monitor, Models MP40 & MP50 · Philips Medizin Systeme Boeblingen GmbH · 2004K032858 · The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors, Release B.O. · Philips Medizin Systeme Boblingen GmbH · 2003K031481 · The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20 · Philips Medizin Systeme Boblingen GmbH · 2003K030038 · Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology and M3185 Opt C41 Wireless Bedside Adaptr · Philips Medical Systems, Inc. · 2003K023871 · M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue Patient Monitor with Portal Technology · Philips Medical Systems · 2002K021778 · Philips Component Compact Monitor, Release a.04, Model #M1275B · Philips Medical Systems · 2002K020531 · Philips Multi-Parameter Module, Model M3001A; Philips Component Compact Monitor, Release a.02, Model M1275B · Philips Medical Systems · 2002K013199 · Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model M1276B · Philips Medical Systems, Inc. · 2001K990972 · HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia Multi-Measurement Server and Compact Portable T · Hewlett-Packard GmbH · 1999K990125 · HP Viridia Component Monitoring System, Model Rev. K · Hewlett-Packard GmbH · 1999K981376 · Hewlett-Packard M1205A Viridia 24 CT · Hewlett-Packard Co. · 1999K960934 · HP M1205A Omnicare Component Monitor System Model 24 · Hewlett-Packard Co. · 1996K941811 · HP M1175A, M1176A, Component Monitoring System · Hewlett-Packard Co. · 1994−25−20−15−10−50
  1. Root · 28 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 24 generations between
  3. 3 generations backK190205 HemoSphere Advanced Monitor, HemoSphere Tissue Oximetry ModuleEdwards Lifesciences, LLC · 2019
  4. 2 generations backK201446 HemoSphere Advanced Monitoring Platform, HemoSphere ClearSight ModuleEdwards Lifesiences, LLC · 2020 · Recalled
  5. 1 generation backK221833 HemoSphere Advanced Monitor, HemoSphere ClearSight ModuleEdwards Lifesciences, LLC · 2022
  6. This deviceK231248 Swan-Ganz Catheters, FloTrac sensors, ClearSight finger cuffs…Edwards Lifesciencess, LLC · 2023
  7. Descendant · cites it directly · 4 of its ownK242451 HemoSphere Alta Advanced Monitoring Platform…Edwards Lifesciences · 2024
  8. Descendant · 2 generations on · 2 of its ownK243781 HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module…Edwards Lifesciences · 2025 · Recalled
  9. Descendant · 3 generations on · 0 of its ownK253186 HemoSphere Nano Monitor (HSNANO1)Edwards Lifesciences, LLC · 2026
  10. Descendant · 2 generations on · 0 of its ownK252533 HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1…Edwards Lifesciences · 2025
  11. Descendant · 3 generations on · 0 of its ownK253034 HemoSphere Stream ModuleEdwards Lifesciences · 2025
Show all 28 generations
  1. Root · 28 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
  2. 27 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
  3. 26 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
  4. 25 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
  5. 24 generations backK990972 HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP…Hewlett-Packard GmbH · 1999
  6. 23 generations backK013199 Philips Component Compact Monitor,Model M1275B, Philips Compenent…Philips Medical Systems, Inc. · 2001
  7. 22 generations backK020531 Philips Multi-Parameter Module, Model M3001A; Philips Component…Philips Medical Systems · 2002
  8. 21 generations backK021778 Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems · 2002
  9. 20 generations backK023871 M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70…Philips Medical Systems · 2002
  10. 19 generations backK030038 Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal…Philips Medical Systems, Inc. · 2003
  11. 18 generations backK031481 The Philips Intellivue MP60, MP70, and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH · 2003
  12. 17 generations backK032858 The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient…Philips Medizin Systeme Boblingen GmbH · 2003
  13. 16 generations backK040304 Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH · 2004
  14. 15 generations backK041235 Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2004
  15. 14 generations backK042845 The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2004
  16. 13 generations backK050141 The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2005
  17. 12 generations backK050762 Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH · 2005
  18. 11 generations backK051106 The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2005
  19. 10 generations backK052801 Intellivue Patient Monitors with Release C.02, Models MP20, MP30…Philips Medizin Systeme Boeblingen GmbH · 2005
  20. 9 generations backK053522 Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH · 2006
  21. 8 generations backK060221 The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
  22. 7 generations backK060541 The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2006 · Recalled
  23. 6 generations backK061052 The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc. · 2006
  24. 5 generations backK062283 The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90…Philips Medical Systems North America, Inc. · 2006
  25. 4 generations backK180881 HemoSphere Advanced Monitor, HemoSphere Pressure CableEdwards Lifesciences, LLC · 2018
  26. 3 generations backK190205 HemoSphere Advanced Monitor, HemoSphere Tissue Oximetry ModuleEdwards Lifesciences, LLC · 2019
  27. 2 generations backK201446 HemoSphere Advanced Monitoring Platform, HemoSphere ClearSight ModuleEdwards Lifesiences, LLC · 2020 · Recalled
  28. 1 generation backK221833 HemoSphere Advanced Monitor, HemoSphere ClearSight ModuleEdwards Lifesciences, LLC · 2022
  29. This deviceK231248 Swan-Ganz Catheters, FloTrac sensors, ClearSight finger cuffs…Edwards Lifesciencess, LLC · 2023

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2024: 12025: 42026: 1
2024high 4 (2025) · low 1 (2024)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 6 · See all
  • K242451HemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1); HemoSphere Alta-…Edwards Lifesciences · 2024 · cites it directly4descendants
  • K243781HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module (HEMTOM10); HemoSphere…Edwards Lifesciences · 2025 · 2 generations on2descendants
  • K253186HemoSphere Nano Monitor (HSNANO1)Edwards Lifesciences, LLC · 2026 · 3 generations on0descendants
  • K252533HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1; ALTASR1)Edwards Lifesciences · 2025 · 2 generations on0descendants
  • K253034HemoSphere Stream ModuleEdwards Lifesciences · 2025 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−28K941811HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co.1994—
−27K960934HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co.1996—
−26K981376Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co.1999—
−25K990125HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH1999—
−24K990972HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia…Hewlett-Packard GmbH1999—
−23K013199Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model…Philips Medical Systems, Inc.2001—
−22K020531Philips Multi-Parameter Module, Model M3001A; Philips Component Compact…Philips Medical Systems2002—
−21K021778Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems2002—
−20K023871M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue…Philips Medical Systems2002—
−19K030038Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology…Philips Medical Systems, Inc.2003—
−18K031481The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20Philips Medizin Systeme Boblingen GmbH2003—
−17K032858The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH2003—
−16K040304Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH2004—
−15K041235Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient MonitorsPhilips Medizin Systeme Boeblingen GmbH2004—
−14K042845The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient…Philips Medizin Systeme Boblingen GmbH2004—
−13K050141The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH2005—
−12K050762Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70…Philips Medizin Systeme Boeblingen GmbH2005—
−11K051106The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH2005—
−10K052801Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH2005—
−9K053522Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors…Philips Medizin Systeme Boeblingen GmbH2006—
−8K060221The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH2006—
−7K060541The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient…Philips Medizin Systeme Boblingen GmbH20062
−6K061052The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc.2006—
−5K062283The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80, MP90 Intellivue Patient…Philips Medical Systems North America, Inc.2006—
−4K180881HemoSphere Advanced Monitor, HemoSphere Pressure CableEdwards Lifesciences, LLC2018—
−3K190205HemoSphere Advanced Monitor, HemoSphere Tissue Oximetry ModuleEdwards Lifesciences, LLC2019—
−2K201446HemoSphere Advanced Monitoring Platform, HemoSphere ClearSight ModuleEdwards Lifesiences, LLC20201
−1K221833HemoSphere Advanced Monitor, HemoSphere ClearSight ModuleEdwards Lifesciences, LLC2022—
0 (this device)K231248Swan-Ganz Catheters, FloTrac sensors, ClearSight finger cuffs, HemoSphere…Edwards Lifesciencess, LLC2023—
+1K242451HemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1)…Edwards Lifesciences2024—
+2K243781HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module (HEMTOM10)…Edwards Lifesciences20251
+3K253186HemoSphere Nano Monitor (HSNANO1)Edwards Lifesciences, LLC2026—
+2K252533HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1; ALTASR1)Edwards Lifesciences2025—
+3K253034HemoSphere Stream ModuleEdwards Lifesciences2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198120
198220
198530
198610
198710
198820
198930
199070
199190
199270
199390
199440
199580
1996100
199770
1998160
1999100
2000230
200190
2002170
200390
2004190
200550
200690
200720
200890
200950
201060
201110
201220
201310
201440
201520
201632
201710
201830
201910

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
202540
202610
FIG. 1 — Lineage of K231248, 1994–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DYG device

  1. #1 K242451 HemoSphere Alta Advanced Monitoring Platform…score 24.2 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K160084Swan Ganz Catheters
Summary page 5
…learSight finger cuffs: DXN HemoSphere Advanced Monitor: DQK, DQE, QAQ, DXN, DSB Regulation Class Class II Predicate Device Swan-Ganz catheters: K160084, cleared on May 03, 2016 FloTrac sensors: K152980, cleared on January 19, 2016 ClearSight f…
Edwards Lifesciences, LLC2016Class I
*K152980Flo Trac sensor, Volume View sensor
Summary page 5
…nitor: DQK, DQE, QAQ, DXN, DSB Regulation Class Class II Predicate Device Swan-Ganz catheters: K160084, cleared on May 03, 2016 FloTrac sensors: K152980, cleared on January 19, 2016 ClearSight finger cuffs: K190130, cleared on June 21, 2019 Hem…
Edwards Lifesciences, LLC20164
*K190130The ClearSight finger cuffs
Summary page 5
…wan-Ganz catheters: K160084, cleared on May 03, 2016 FloTrac sensors: K152980, cleared on January 19, 2016 ClearSight finger cuffs: K190130, cleared on June 21, 2019 HemoSphere Advanced Monitoring System: K221833, cleared on Nov 7, 2022 Device…
Edwards Lifesciences, LLC2019—
*K221833HemoSphere Advanced Monitor, HemoSphere ClearSight Module
Summary page 5
…2980, cleared on January 19, 2016 ClearSight finger cuffs: K190130, cleared on June 21, 2019 HemoSphere Advanced Monitoring System: K221833, cleared on Nov 7, 2022 Device Swan-Ganz Catheters: Description The Swan-Ganz catheters are flow-directed pulm…
Edwards Lifesciences, LLC2022—

Also cleared against K160084: 5 other devices →

What descends from it? (6)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K242451HemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1); HemoSphere Alta-…Edwards Lifesciences20244
K242909FloTrac sensors; FloTrac Jr sensors; Acumen IQ sensors; VolumeView sensorsEdwards Lifesciences, LLC20250

Has anything in its family been recalled? (2 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 8, 2026Class IIZ-2203-2026Process change controlCatheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss.
Apr 8, 2026Class IIZ-2202-2026Process change controlCatheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K160084Swan Ganz CathetersEdwards Lifesciences, LLC · 2016 · Direct predicate · ◆ in the 2016 ancestors bar of FIG. 14 Class I recalls
  • K160552EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight System, EV1000 Clinical PlatformEdwards Lifesciences, LLC · 2016 · 2 generations back · ◆ in the 2016 ancestors bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 29 years and passes through 10 companies; a new generation was cleared every 4 months on median.
  • 43 of the 260 ancestors have a recall of any class; 2 have a Class I recall.
  • Of its descendants, K242451 (Edwards Lifesciences, 2024) has gone furthest, with 4 descendants of its own.
  • 5 other devices also cite its predicate K160084.

How does its category compare?

All DYG devices

DYG Catheter, Flow Directed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · DYG

3in 2024

2008: 12011: 12016: 12020: 12022: 12023: 12024: 3
2007high 3 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DYG

188in 2024

2024: 188 days median
2007high 188 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DYG

2in 2019

2007: 12009: 32013: 12018: 4, 4 Class I2019: 22026 (partial year): 2
2007high 4 (2018) · low 0 (2008)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · DYG

268in 2025

2007: 1682008: 4002009: 1452010: 1472011: 2492012: 2212013: 1492014: 1782015: 1632016: 1542017: 1152018: 1332019: 1442020: 1042021: 972022: 1302023: 2292024: 2262025: 268
2007high 400 (2008) · low 97 (2021)2025

MAUDE reports naming product code DYG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—1168
20081—0400
20090—3145
20100—0147
20111—0249
20120—0221
20130—1149
20140—0178
20150—0163
20161—0154
20170—0115
20180—4 (4)133
20190—2144
20201—0104
20210—097
20221—0130
20231—0229
202431880226
20250—0268
20260—2—

What is it indicated for?

Swan-Ganz catheters- Indications for Use: The Swan-Ganz catheters are diagnostic and monitoring tools used for hemodynamic monitoring of adult critically ill patients including but limited to post major surgical recovery, trauma, sepsis, burns, pulmonary disease, pulmonary failure, cardiac disease including heart failure. Models 096F6, 096F6P, TS105F5, 132F5, 131F7, 131F75P, 831F75, 831F75P, 834F75, and 834F75P are intended for adult and pediatric…

Read the full statement (868 words)

Swan-Ganz catheters- Indications for Use:

The Swan-Ganz catheters are diagnostic and monitoring tools used for hemodynamic monitoring of adult critically ill patients including but limited to post major surgical recovery, trauma, sepsis, burns, pulmonary disease, pulmonary failure, cardiac disease including heart failure.

Models 096F6, 096F6P, TS105F5, 132F5, 131F7, 131F75P, 831F75, 831F75P, 834F75, and 834F75P are intended for adult and pediatric patients:

The Swan-Ganz catheters are diagnostic and monitoring tools used for hemodynamic monitoring of critically ill adult and pediatric patients ≥12 years of age including but not limited to post major surgical recovery, trauma, sepsis, burns, pulmonary disease, pulmonary failure, cardiac disease including heart failure.

FloTrac sensors- Indications for Use:

The FloTrac sensor is indicated for use in intravascular pressure monitoring. It is also indicated for use with the Edwards arterial pressure based cardiac output monitoring devices or hardware to measure cardiac output. They are intended to be used in adult patients.

Models MHD6, MHD8, MHD65, and MHD85 are intended for adult and pediatric patients:

The FloTrac sensor is indicated for use in intravascular pressure monitoring. It is also indicated for use with the Edwards arterial pressure based cardiac output monitoring devices or hardware to measure cardiac output. The FloTrac sensor is indicated for use in adult and pediatric patients ≥12 years of age.

ClearSight finger cuffs- Indications for Use:

The Acumen IQ are indicated for patients over 18 years of age to non-invasively measure blood pressure and associated hemodynamic parameters when used with EV1000 clinical platform or HemoSphere advanced monitoring platform.

The ClearSight finger cuffs are indicated for adult and pediatric patients ≥12 years of age to noninvasively measure blood pressure and associated hemodynamic parameters when used with EV1000 clinical platform or HemoSphere advanced monitoring platform.

HemoSphere Advanced Monitor with HemoSphere Swan-Ganz Module- Indications for Use:

The HemoSphere advanced monitor when used with the HemoSphere Swan-Ganz module and Edwards Swan-Ganz catheters is indicated for use in adult and pediatric critical care patients requiring monitoring of cardiac output (continuous [CO] and intermittent [iCO]) and derived hemodynamic parameters in a hospital environment. It may be used for monitoring hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. Refer to the Edwards Swan-Ganz catheter indications for use statement for information on target patient population specific to the catheter being used.

Refer to the Intended Use statement for a complete list of measured and derived parameters available for each patient population.

HemoSphere Advanced Monitor with HemoSphere Pressure Cable- Indications for Use:

The HemoSphere advanced monitor when used with the HemoSphere pressure cable is indicated for use in adult and pediatric critical care patients in which the balance between cardiac function, fluid status, vascular resistance and pressure needs continuous assessment. It may be used for monitoring of hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. Refer to the Edwards FloTrac sensor, Acumen IQ sensor, and TruWave DPT indications for use statements for information on target patient populations specific to the sensor/transducer being used.

The Edwards Acumen Hypotension Prediction Index feature provides the clinician with physiological insight into a patient’s likelihood of future hypotensive events (defined as mean arterial pressure < 65 mmHg for at least one minute in duration) and the associated hemodynamics. The Acumen HPI™ feature is intended for use in surgical or non-surgical patients receiving advanced hemodynamic monitoring. The Acumen HPI™ feature is considered to be additional quantitative information regarding the patient’s physiological condition for reference only and no therapeutic decisions should be made based solely on the Acumen Hypotension Prediction Index (HPI) parameter.

Refer to the Intended Use statement for a complete list of measured and derived parameters available for each patient population.

HemoSphere Advanced Monitor with HemoSphere ClearSight Module - Indications for Use:

The HemoSphere advanced monitor when used with the HemoSphere ClearSight module, pressure controller and a compatible Edwards finger cuff are indicated for adult and pediatric patients in which the balance between cardiac function, fluid status and vascular resistance needs continuous assessment. It may be used for monitoring hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. In addition, the noninvasive system is indicated for use in patients with co-morbidities for which hemodynamic optimization is desired and invasive measurements are difficult. The HemoSphere advanced monitor and compatible Edwards finger cuffs noninvasively measures blood pressure and associated hemodynamic parameters.

Refer to the ClearSight finger cuff and Acumen IQ finger cuff indications for use statements for information on target patient population specific to the finger cuff being used.

The Edwards Acumen Hypotension Prediction Index (HPI) feature provides the clinician with physiological insight into patient’s likelihood of future hypotensive events (defined as mean arterial pressure < 65 mmHg for at least one minute in duration) and the associated hemodynamics. The Acumen HPI feature is intended for use in surgical patients receiving advanced hemodynamic monitoring. The Acumen HPI feature is considered to be additional quantitative information regarding the patient’s physiological condition for reference only and no therapeutic decisions should be made based solely on the Acumen Hypotension Prediction Index (HPI) parameter.

Refer to the Intended Use statement for a complete list of measured and derived parameters available for each patient population.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231248: Swan-Ganz Catheters, FloTrac sensors, ClearSight finger cuffs, HemoSphere Advanced Monitoring Platform.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231248

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026