510(k) · Cleared
ClearedHemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1); HemoSphere Alta- monitor pressure cable (HEMAPSC200);Acumen AFM cable- HemoSphere Alta monitor (HEMAFM100)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Edwards Lifesciences · DYG Catheter, Flow Directed
Cleared on Dec 9, 2024 as substantially equivalent to K232294 (Edwards Lifesciences, LLC, 2023) and 6 other predicates after a 115-day review. Its family tree reaches back 39 generations to 1994. 3 of the 402 devices in its family, counting itself, have a Class I recall. 4 later devices descend from it.
- Decided
- Dec 9, 2024
- Review
- 115 days
- Class
- Class II
- Product code
- DYG
- Recalls
- None
- Predicates
- 7
Its longest line of descent runs back 39 generations to K941811 (1994). 397 ancestors in all, the oldest K810124 (1981). 4 later devices descend from it, 2 citing it directly. 3 of the 402 devices in this family, counting this one, have a Class I recall.
- Root · 39 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
- 35 generations between
- 3 generations backK161531 IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and…Philips Medizin Systeme Boeblingen GmbH · 2016 · Recalled
- 2 generations backK221704 HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP)…Edwards Lifesciences, LLC · 2022
- 1 generation backK232294 HemoSphere Alta Advanced Monitoring Platform; HemoSphere Alta™…Edwards Lifesciences, LLC · 2023
- This deviceK242451 HemoSphere Alta Advanced Monitoring Platform…Edwards Lifesciences · 2024
- Descendant · cites it directly · 2 of its ownK243781 HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module…Edwards Lifesciences · 2025 · Recalled
- Descendant · 2 generations on · 0 of its ownK253186 HemoSphere Nano Monitor (HSNANO1)Edwards Lifesciences, LLC · 2026
- Descendant · cites it directly · 0 of its ownK252533 HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1…Edwards Lifesciences · 2025
- Descendant · 2 generations on · 0 of its ownK253034 HemoSphere Stream ModuleEdwards Lifesciences · 2025
Show all 39 generations
- Root · 39 generations backK941811 HP M1175A, M1176A, Component Monitoring SystemHewlett-Packard Co. · 1994
- 38 generations backK960934 HP M1205A Omnicare Component Monitor System Model 24Hewlett-Packard Co. · 1996
- 37 generations backK981376 Hewlett-Packard M1205A Viridia 24 CTHewlett-Packard Co. · 1999
- 36 generations backK990125 HP Viridia Component Monitoring System, Model Rev. KHewlett-Packard GmbH · 1999
- 35 generations backK990972 HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP…Hewlett-Packard GmbH · 1999
- 34 generations backK013199 Philips Component Compact Monitor,Model M1275B, Philips Compenent…Philips Medical Systems, Inc. · 2001
- 33 generations backK020531 Philips Multi-Parameter Module, Model M3001A; Philips Component…Philips Medical Systems · 2002
- 32 generations backK021778 Philips Component Compact Monitor, Release a.04, Model #M1275BPhilips Medical Systems · 2002
- 31 generations backK023871 M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70…Philips Medical Systems · 2002
- 30 generations backK030038 Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal…Philips Medical Systems, Inc. · 2003
- 29 generations backK031481 The Philips Intellivue MP60, MP70, and MP90 Patient Monitors…Philips Medizin Systeme Boblingen GmbH · 2003
- 28 generations backK032858 The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient…Philips Medizin Systeme Boblingen GmbH · 2003
- 27 generations backK040304 Philips Intellivue Patient Monitor, Models MP40 & MP50Philips Medizin Systeme Boeblingen GmbH · 2004
- 26 generations backK041235 Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2004
- 25 generations backK042845 The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2004
- 24 generations backK050141 The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue…Philips Medizin Systeme Boeblingen GmbH · 2005
- 23 generations backK050762 Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50…Philips Medizin Systeme Boeblingen GmbH · 2005
- 22 generations backK051106 The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2005
- 21 generations backK052801 Intellivue Patient Monitors with Release C.02, Models MP20, MP30…Philips Medizin Systeme Boeblingen GmbH · 2005
- 20 generations backK053522 Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient…Philips Medizin Systeme Boeblingen GmbH · 2006
- 19 generations backK060221 The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
- 18 generations backK060541 The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue…Philips Medizin Systeme Boblingen GmbH · 2006 · Recalled
- 17 generations backK061052 The Philips Intellivue Patient Monitors, Models…Philips Medical Systems North America, Inc. · 2006
- 16 generations backK061610 Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90…Philips Medizin Systeme Boeblingen GmbH · 2006
- 15 generations backK063315 Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60…Philips Medizin Systeme Boeblingen GmbH · 2006
- 14 generations backK071426 MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2007
- 13 generations backK083517 Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009 · Recalled
- 12 generations backK091927 Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2009
- 11 generations backK100939 Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010
- 10 generations backK101449 Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2010
- 9 generations backK110622 Intellivue Patient MonitorPhilips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2011 · Recalled
- 8 generations backK113657 Intellivue Patient MonitorPhilips Medizin Systeme Boblingen GmbH · 2012
- 7 generations backK122439 Intellivue Patient MonitorPhilips Medizin Systeme Boeblingen GmbH · 2012 · Recalled
- 6 generations backK130849 Intellivue Patient Monitor MX400; Intellivue Patient Monitor MX450Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2013 · Recalled
- 5 generations backK141015 Intellivue Patient Monitor MX400, Intellivue Patient Monitor MX450…Philips Medizinsysteme Boeblingen GmbH, Cardiac AN · 2014 · Recalled
- 4 generations backK150975 Philips IntelliVue MP2/MP5/MPSC Patient Monitors, Philips IntelliVue…Philips Medizin Systeme Boeblingen GmbH · 2015 · Recalled
- 3 generations backK161531 IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and…Philips Medizin Systeme Boeblingen GmbH · 2016 · Recalled
- 2 generations backK221704 HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP)…Edwards Lifesciences, LLC · 2022
- 1 generation backK232294 HemoSphere Alta Advanced Monitoring Platform; HemoSphere Alta™…Edwards Lifesciences, LLC · 2023
- This deviceK242451 HemoSphere Alta Advanced Monitoring Platform…Edwards Lifesciences · 2024
Class I recalls in this family
Most influential descendants
Showing 4 of 4 · See all- K243781HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module (HEMTOM10); HemoSphere…Edwards Lifesciences · 2025 · cites it directly2descendants
- K253186HemoSphere Nano Monitor (HSNANO1)Edwards Lifesciences, LLC · 2026 · 2 generations on0descendants
- K252533HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1; ALTASR1)Edwards Lifesciences · 2025 · cites it directly0descendants
- K253034HemoSphere Stream ModuleEdwards Lifesciences · 2025 · 2 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −39 | K941811 | HP M1175A, M1176A, Component Monitoring System | Hewlett-Packard Co. | 1994 | — |
| −38 | K960934 | HP M1205A Omnicare Component Monitor System Model 24 | Hewlett-Packard Co. | 1996 | — |
| −37 | K981376 | Hewlett-Packard M1205A Viridia 24 CT | Hewlett-Packard Co. | 1999 | — |
| −36 | K990125 | HP Viridia Component Monitoring System, Model Rev. K | Hewlett-Packard GmbH | 1999 | — |
| −35 | K990972 | HP Viridia Component Monitoring System, HP Viridia CMS 24/26, HP Viridia… | Hewlett-Packard GmbH | 1999 | — |
| −34 | K013199 | Philips Component Compact Monitor,Model M1275B, Philips Compenent Rack, Model… | Philips Medical Systems, Inc. | 2001 | — |
| −33 | K020531 | Philips Multi-Parameter Module, Model M3001A; Philips Component Compact… | Philips Medical Systems | 2002 | — |
| −32 | K021778 | Philips Component Compact Monitor, Release a.04, Model #M1275B | Philips Medical Systems | 2002 | — |
| −31 | K023871 | M3046A (M2/M3/M4) Compact Portable Patient Monitor and MP60 & MP70 Intellivue… | Philips Medical Systems | 2002 | — |
| −30 | K030038 | Philips MP60, MP70 and MP90 Intellivue Patient Monitors with Portal Technology… | Philips Medical Systems, Inc. | 2003 | — |
| −29 | K031481 | The Philips Intellivue MP60, MP70, and MP90 Patient Monitors, Release a.20 | Philips Medizin Systeme Boblingen GmbH | 2003 | — |
| −28 | K032858 | The Philips Intellivue MP40, MP50, MP60, MP70,and MP90 Patient Monitors… | Philips Medizin Systeme Boblingen GmbH | 2003 | — |
| −27 | K040304 | Philips Intellivue Patient Monitor, Models MP40 & MP50 | Philips Medizin Systeme Boeblingen GmbH | 2004 | — |
| −26 | K041235 | Philips MP20, MP30, MP40, MP50. MP60, MP70 and MP90 Intellivue Patient Monitors | Philips Medizin Systeme Boeblingen GmbH | 2004 | — |
| −25 | K042845 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, and MP90 Intellivue Patient… | Philips Medizin Systeme Boblingen GmbH | 2004 | — |
| −24 | K050141 | The Philips MP20, MP30, MP40, MP50, MP60, MP70 and MP90 Intellivue Patient… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −23 | K050762 | Philips Intellivue Patient Monitor, Models MP20, MP30, MP40, MP50, MP60, MP70… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −22 | K051106 | The Philips MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −21 | K052801 | Intellivue Patient Monitors with Release C.02, Models MP20, MP30, MP40, MP50… | Philips Medizin Systeme Boeblingen GmbH | 2005 | — |
| −20 | K053522 | Philips MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue Patient Monitors… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −19 | K060221 | The Phillips, Model MP20,MP30,MP40,MP50,MP60,MP70,MP80,and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −18 | K060541 | The Philips MP20,MP30,MP40,MP50,MP60,MP70,MP80 and MP90 Intellivue Atient… | Philips Medizin Systeme Boblingen GmbH | 2006 | 2 |
| −17 | K061052 | The Philips Intellivue Patient Monitors, Models… | Philips Medical Systems North America, Inc. | 2006 | — |
| −16 | K061610 | Philips Model MP20, MP30, MP40, MP50, MP60, MP70, MP80 and MP90 Intellivue… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −15 | K063315 | Intellivue Patient Monitors, Models MP20, MP30, MP40, MP50, MP60, MP70, MP80… | Philips Medizin Systeme Boeblingen GmbH | 2006 | — |
| −14 | K071426 | MP2, X2, MP5, MP20, MP30, MP40, MP50, MP60, MP70, MP80, and MP90 Intellivue… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2007 | — |
| −13 | K083517 | Intellivue Patient Monitor, Models MP2, MP5, MP20, MP30, MP40, MP50, MO60… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2009 | 2 |
| −12 | K091927 | Intellivue Patient Monitors ,Models MP40, MP50, MP60, MP70, MP80, MP90 | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2009 | — |
| −11 | K100939 | Intellivue Patient Monitor Model: MP2, MP5, MP5T, MP20, MP30, MP40, MP50… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2010 | — |
| −10 | K101449 | Intellivue Patient Monitor | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2010 | — |
| −9 | K110622 | Intellivue Patient Monitor | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2011 | 2 |
| −8 | K113657 | Intellivue Patient Monitor | Philips Medizin Systeme Boblingen GmbH | 2012 | — |
| −7 | K122439 | Intellivue Patient Monitor | Philips Medizin Systeme Boeblingen GmbH | 2012 | 4 |
| −6 | K130849 | Intellivue Patient Monitor MX400; Intellivue Patient Monitor MX450 | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2013 | 8 |
| −5 | K141015 | Intellivue Patient Monitor MX400, Intellivue Patient Monitor MX450, Intellivue… | Philips Medizinsysteme Boeblingen GmbH, Cardiac AN | 2014 | 1 |
| −4 | K150975 | Philips IntelliVue MP2/MP5/MPSC Patient Monitors, Philips IntelliVue X1 and X2… | Philips Medizin Systeme Boeblingen GmbH | 2015 | 1 |
| −3 | K161531 | IntelliVue Patient Monitors MP2, MP5, MP5T, MP5SC, and Multi-Measurement… | Philips Medizin Systeme Boeblingen GmbH | 2016 | 1 |
| −2 | K221704 | HemoSphere Advanced Monitor, Right Ventricular Pressure (RVP), Global… | Edwards Lifesciences, LLC | 2022 | — |
| −1 | K232294 | HemoSphere Alta Advanced Monitoring Platform; HemoSphere Alta™ Advanced… | Edwards Lifesciences, LLC | 2023 | — |
| 0 (this device) | K242451 | HemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1)… | Edwards Lifesciences | 2024 | — |
| +1 | K243781 | HemoSphere Advanced Monitor (HEM1); HemoSphere Technology Module (HEMTOM10)… | Edwards Lifesciences | 2025 | 1 |
| +2 | K253186 | HemoSphere Nano Monitor (HSNANO1) | Edwards Lifesciences, LLC | 2026 | — |
| +1 | K252533 | HemoSphere Alta Advanced Monitoring Platform (ALTAALL1; ALTACR1; ALTASR1) | Edwards Lifesciences | 2025 | — |
| +2 | K253034 | HemoSphere Stream Module | Edwards Lifesciences | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1981 | 2 | 0 |
| 1982 | 2 | 0 |
| 1985 | 3 | 0 |
| 1986 | 1 | 0 |
| 1987 | 1 | 0 |
| 1988 | 2 | 0 |
| 1989 | 4 | 0 |
| 1990 | 8 | 0 |
| 1991 | 11 | 0 |
| 1992 | 8 | 0 |
| 1993 | 11 | 0 |
| 1994 | 5 | 0 |
| 1995 | 11 | 0 |
| 1996 | 12 | 0 |
| 1997 | 9 | 1 |
| 1998 | 20 | 0 |
| 1999 | 12 | 0 |
| 2000 | 27 | 0 |
| 2001 | 15 | 0 |
| 2002 | 25 | 0 |
| 2003 | 17 | 0 |
| 2004 | 27 | 0 |
| 2005 | 12 | 0 |
| 2006 | 17 | 0 |
| 2007 | 8 | 0 |
| 2008 | 13 | 0 |
| 2009 | 14 | 0 |
| 2010 | 12 | 0 |
| 2011 | 4 | 0 |
| 2012 | 5 | 0 |
| 2013 | 3 | 0 |
| 2014 | 4 | 0 |
| 2015 | 4 | 0 |
| 2016 | 3 | 2 |
| 2017 | 1 | 0 |
| 2018 | 4 | 0 |
| 2019 | 4 | 0 |
| 2020 | 3 | 0 |
| 2021 | 3 | 0 |
| 2022 | 4 | 0 |
| 2023 | 7 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2025 | 3 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DYG device
- #1 K231248 Swan-Ganz Catheters, FloTrac sensors…score 18.1 · 28 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (7)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K232294 | HemoSphere Alta Advanced Monitoring Platform; HemoSphere Alta™ Advanced Monitor (Smart…Summary page 8…III. Predicate Device Primary - HemoSphere Alta Advanced Monitoring Platform manufactured by Predicate Device: Edwards Lifesciences, K232294, cleared on October 31st, 2023. It is the base device on which the software modifications have been… | 2023 |
| * | K223865 | HemoSphere Advanced Monitor, HemoSphere ClearSight Module, Acumen Assisted Fluid…Summary page 8…(RVCO) Algorithm. Additional - HemoSphere Advanced Monitoring Platform by Edwards Predicate Lifesciences, K223865, cleared on June 9th, 2023, utilized for AFM Devices: automated fluid tracking and the automatic zeroing of t… | 2023 |
| * | K223651 | Cerebral Adaptive Index (CAI) AlgorithmSummary page 8…reference sensor feature. - Cerebral Adaptive Index (CAI) algorithm by Edwards Lifesciences, K223651, cleared on May 26, 2023, utilized for the Cerebral Adaptive Index (CAI) parameter.… | 2023 |
| * | K230612 | Edwards Algorithm for Measurement of Blood HemoglobinSummary page 8…Adaptive Index (CAI) parameter. - Edwards Algorithm for Measurement of Blood Hemoglobin by Edwards Lifesciences, K230612, cleared on November 17th, 2023, utilized for the Total Blood Hemoglobin (tHb) parameter.… | 2023 |
| * | K230579 | Smart Wedge algorithmSummary page 9…Page 2 of 17 K242451 - Smart Wedge algorithm by Edwards Lifesciences, K230579 cleared on August 17th, 2023, utilized for the Smart Wedge func… | 2023 |
| * | K230057 | Acumen Hypotension Prediction Index (HPI) AlgorithmSummary page 9…functionality. - Acumen Hypotension Prediction Index (HPI) algorithm by Edwards Lifesciences, K230057, cleared on June 8th, 2023, utilized for the HPI Adjustable MAP (Hypotension threshold) feature.… | 2023 |
| * | K231248 | Swan-Ganz Catheters, FloTrac sensors, ClearSight finger cuffs, HemoSphere Advanced…Summary page 9…Trac sensors, ClearSight finger cuffs, HemoSphere Advanced Monitoring Platform by Edwards Lifesciences, K231248, cleared on September 21, 2023, for Pediatric patients ≥ 12 years of age Indication expansion wh… | 2023 |
What descends from it? (4)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (3 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K160084Swan Ganz CathetersEdwards Lifesciences, LLC · 2016 · 2 generations back · ◆ in the 2016 ancestors bar of FIG. 14 Class I recalls
- K160552EV1000 Clinical Platform with ClearSight Finger Cuff or ClearSight System, EV1000 Clinical PlatformEdwards Lifesciences, LLC · 2016 · 3 generations back · ◆ in the 2016 ancestors bar of FIG. 11 Class I recall
- K970209Capnocheck PlusBci Intl., Inc. · 1997 · 11 generations back · ◆ in the 1997 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 30 years and passes through 10 companies; a new generation was cleared every 5 months on median.
- 81 of the 397 ancestors have a recall of any class; 3 have a Class I recall.
- Of its descendants, K243781 (Edwards Lifesciences, 2025) has gone furthest, with 2 descendants of its own.
How does its category compare?
All DYG devicesDYG Catheter, Flow Directed: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · DYG
3in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · DYG
188in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DYG
2in 2019
Class I (4 since 2007) Class II/III not classified
Adverse event reports per year · DYG
268in 2025
MAUDE reports naming product code DYG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 1 | 168 |
| 2008 | 1 | — | 0 | 400 |
| 2009 | 0 | — | 3 | 145 |
| 2010 | 0 | — | 0 | 147 |
| 2011 | 1 | — | 0 | 249 |
| 2012 | 0 | — | 0 | 221 |
| 2013 | 0 | — | 1 | 149 |
| 2014 | 0 | — | 0 | 178 |
| 2015 | 0 | — | 0 | 163 |
| 2016 | 1 | — | 0 | 154 |
| 2017 | 0 | — | 0 | 115 |
| 2018 | 0 | — | 4 (4) | 133 |
| 2019 | 0 | — | 2 | 144 |
| 2020 | 1 | — | 0 | 104 |
| 2021 | 0 | — | 0 | 97 |
| 2022 | 1 | — | 0 | 130 |
| 2023 | 1 | — | 0 | 229 |
| 2024 | 3 | 188 | 0 | 226 |
| 2025 | 0 | — | 0 | 268 |
| 2026 | 0 | — | 2 | — |
What is it indicated for?
HemoSphere Alta™ Advanced Monitor with Swan-Ganz Technology The HemoSphere Alta monitor when used with the HemoSphere Alta Swan-Ganz patient cable and Edwards Swan-Ganz catheters is indicated for use in adult and pediatric critical care patients requiring monitoring of cardiac output (continuous [CO] and intermittent [iCO]) and derived hemodynamic parameters in a hospital environment. Pulmonary artery blood temperature monitoring is used to compute…
Read the full statement (1,413 words)
HemoSphere Alta™ Advanced Monitor with Swan-Ganz Technology
The HemoSphere Alta monitor when used with the HemoSphere Alta Swan-Ganz patient cable and Edwards Swan-Ganz catheters is indicated for use in adult and pediatric critical care patients requiring monitoring of cardiac output (continuous [CO] and intermittent [iCO]) and derived hemodynamic parameters in a hospital environment. Pulmonary artery blood temperature monitoring is used to compute continuous and intermittent CO with thermodilution technologies. It may be used for monitoring hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. Refer to the Edwards Swan-Ganz catheter and Swan-Ganz Jr catheter indications for use statement for information on target patient population specific to the catheter being used.
The Global Hypoperfusion Index (GHI) algorithm provides the clinician with physiological insight into a patient's likelihood of future hemodynamic instability. The GHI algorithm is intended for use in surgical or non-surgical patients receiving advanced hemodynamic monitoring with the Swan-Ganz catheter. The GHI algorithm is considered to provide additional information regarding the patient's predicted future risk for clinical deterioration, as well as identifying patients at low risk for deterioration. The product predictions are for reference only and no therapeutic decisions should be made based solely on the GHI algorithm predictions.
When used in combination with a Swan-Ganz catheter connected to a pressure cable and pressure transducer, the Edwards Lifesciences Smart Wedge algorithm measures and provides pulmonary artery occlusion pressure and assesses the quality of the pulmonary artery occlusion pressure measurement. The Smart Wedge algorithm is indicated for use in critical care patients over 18 years of age receiving advanced hemodynamic monitoring. The Smart Wedge algorithm is considered to be additional quantitative information regarding the patient's physiological condition for reference only and no therapeutic decisions should be made based solely on the Smart Wedge algorithm parameters.
HemoSphere Alta Advanced Monitor with HemoSphere Oximetry Cable
The HemoSphere Alta monitor when used with the HemoSphere oximetry cable and Edwards oximetry catheters is indicated for use in adult and pediatric critical care patients requiring monitoring of venous oxygen saturation (SvO2 and ScvO2) and derived hemodynamic parameters in a hospital environment. Refer to the Edwards oximetry catheter indications for use statement for information on target patient population specific to the catheter being used.
HemoSphere Alta Advanced Monitor with HemoSphere Pressure Cable or HemoSphere Alta Monitor Pressure Cable
The HemoSphere Alta monitor when used with the HemoSphere Pressure Cable or HemoSphere Alta monitor Pressure cable is indicated for use in adult and pediatric critical care patients in which the balance between cardiac function, fluid status, vascular resistance and pressure needs continuous assessment. It may be used for monitoring hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. Refer to the Edwards FloTrac, FloTrac Jr, Acumen IQ, and TruWave DPT sensor indications for use statement for information on target patient population specific to the sensor being used.
The Edwards Lifesciences Acumen Hypotension Prediction Index software feature provides the clinician with physiological insight into a patient’s likelihood of future hypotensive events and the associated hemodynamics. The Acumen HPI feature is intended for use in surgical or non-surgical patients receiving advanced hemodynamic monitoring. The Acumen HPI feature is considered to be additional quantitative information regarding the patient’s physiological condition for reference only and no therapeutic decisions should be made based solely on the Hypotension Prediction Index (HPI) parameter.
When used in combination with the Swan-Ganz technology connected to a compatible Swan-Ganz catheter, the Edward Lifesciences Right Ventricular Pressure (RVP) algorithm provides the clinician with physiological insight into the hemodynamic status of the right ventricle of the heart. The RVP algorithm is indicated for critically ill patients over 18 years of age receiving advanced hemodynamic monitoring in the operating room (OR) and intensive care unit (ICU). The RVP algorithm is considered to be additional quantitative information regarding the patient’s physiological condition for reference only and no therapeutic decisions should be made based solely on the Right Ventricular Pressure (RVP) parameters.
When used in combination with the HemoSphere Pressure Cable connected to a compatible Swan-Ganz catheter, the Right Ventricular Cardiac Output (RVCO) feature provides the clinician with physiological insight into the hemodynamic status of the right ventricle of the heart. The RVCO algorithm is intended for use in surgical or non-surgical patients over 18 years of age that require advanced hemodynamic monitoring. The Right Ventricular Cardiac output provides a continuous cardiac output and derived parameters.
The Cerebral Adaptive Index (CAI) Algorithm is an informational index to help assess the level of coherence or lack thereof between Mean Arterial Pressure (MAP) and the Absolute Levels of Blood Oxygenation Saturation (StO2) in patient's cerebral tissue. MAP is acquired by the HemoSphere pressure cable or HemoSphere Alta Pressure Cable and StO2 is acquired by the ForeSight oximeter cable. CAI is intended for use in patients over 18 years of age receiving advanced hemodynamic monitoring. CAI is not indicated to be used for treatment of any disease or condition and no therapeutic decisions should be made based solely on the Cerebral Adaptive Index (CAI) Algorithm.
HemoSphere Alta Advanced Monitor with Acumen Assisted Fluid Management Feature and Acumen IQ Sensor
The Acumen assisted fluid management (AFM) software feature provides the clinician with physiological insight into a patient’s estimated response to fluid therapy and the associated hemodynamics. The Acumen AFM software feature is intended for use in surgical patients ≥18 years of age, that require advanced hemodynamic monitoring. The Acumen AFM software feature offers suggestions regarding the patient’s physiological condition and estimated response to fluid therapy.
Acumen AFM fluid administration suggestions are offered to the clinician; the decision to administer a fluid bolus is made by the clinician, based upon review of the patient's hemodynamics. No therapeutic decisions should be made based solely on the assisted fluid management suggestions.
Acumen IQ Fluid Meter
The Acumen IQ fluid meter is a sterile single use device that is intended to be used with the HemoSphere Alta AFM cable and AFM software feature to inform the user of the rate of flow. The device is intended to be used by qualified personnel or clinicians in a clinical setting for up to 24 hours.
HemoSphere Alta Advanced Monitor with ForeSight Oximeter Cable
The non-invasive ForeSight oximeter cable is intended for use as an adjunct monitor of absolute regional hemoglobin oxygen saturation of blood under the sensors in individuals at risk for reduced flow or no-flow ischemic states. The ForeSight oximeter cable is also intended to monitor relative changes of total hemoglobin of blood under the sensors. The ForeSight oximeter cable is intended to allow for the display of StO2 and relative change in total hemoglobin on the HemoSphere Alta monitor.
• When used with large sensors, the ForeSight Oximeter Cable is indicated for use on adults and transitional adolescents ≥40 kg.
• When used with Medium Sensors, the ForeSight Oximeter Cable is indicated for use on pediatric subjects ≥3 kg.
• When used with Small Sensors, the ForeSight Oximeter Cable is indicated for cerebral use on pediatric subjects <8 kg and non-cerebral use on pediatric subjects <5kg.
The Edwards Algorithm for Measurement of Blood Hemoglobin is indicated for continuously monitoring changes to hemoglobin concentration in the circulating blood of adults and transitional adolescents ≥ 40 kg receiving advanced hemodynamic monitoring using HemoSphere ForeSight Oximeter Cable and ForeSight IQ Sensors in cerebral locations.
HemoSphere Alta Advanced Monitor with ClearSight Technology
The HemoSphere Alta Monitor when used with the HemoSphere ClearSight technology, pressure controller and a compatible Edwards finger cuff are indicated for Adult and Pediatric patients of age in which the balance between cardiac function, fluid status and vascular resistance needs continuous assessment. It may be used for monitoring hemodynamic parameters in conjunction with a perioperative goal directed therapy protocol in a hospital environment. In addition, the noninvasive system is indicated for use in patients with co-morbidities for which hemodynamic optimization is desired and invasive measurements are difficult. The HemoSphere Alta monitor and compatible Edwards' finger cuffs noninvasively measures blood pressure and associated hemodynamic parameters.
The Edwards Lifesciences Acumen Hypotension Prediction Index feature provides the clinician with physiological insight into a patient’s likelihood of future hypotensive events and the associated hemodynamics. The Acumen HPI feature is intended for use in surgical patients or non-surgical patients receiving advanced hemodynamic monitoring. The Acumen HPI feature is considered to be additional quantitative information regarding the patient’s physiological condition for reference only and no therapeutic decisions should be made based solely on the Hypotension Prediction Index (HPI) parameter.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K242451 · printed Nov 6, 2026
Cite this page
510(k) Report. “K242451: HemoSphere Alta Advanced Monitoring Platform (ALTAALL1/ALTCR1/ALTASR1); HemoSphere Alta- monitor pressure cable (HEMAPSC200);Acumen AFM cable- HemoSphere Alta monitor (HEMAFM100).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242451
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026