Rapid ASPECTS (v3)

K232156510(k) TraditionalCleared Jan 19, 2024183-day reviewClass II21 CFR 892.2060

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ischemaview, Inc. · POK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer

Cleared on Jan 19, 2024 as substantially equivalent to K200760 (Ischemaview, Inc., 2020) after a 183-day review. Its family tree reaches back 2 generations to 2017.

Decided
Jan 19, 2024
Review
183 days
Class
Class II
Product code
POK
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to DEN170022 (2017). No later device cites it as a predicate yet.

DEN170022 · QuantX · Quantitative Insights, Inc. · 2017K200760 · Rapid ASPECTS · Ischemaview, Inc. · 2020201620182020202220242026
  1. Root · 2 generations backDEN170022 QuantXQuantitative Insights, Inc. · 2017
  2. 1 generation backK200760 Rapid ASPECTSIschemaview, Inc. · 2020
  3. This deviceK232156 Rapid ASPECTS (v3)Ischemaview, Inc. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2DEN170022QuantXQuantitative Insights, Inc.2017—
−1K200760Rapid ASPECTSIschemaview, Inc.2020—
0 (this device)K232156Rapid ASPECTS (v3)Ischemaview, Inc.2024—
FIG. 1 — Lineage of K232156, 2017–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in POK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new POK device

  1. #1 K242342 Fetal EchoScanscore 16.7 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200760Rapid ASPECTS
Summary page 5
…Panel: Predicate Devices: The iSchemaView Rapid is claimed to be substantially equivalent to the following legally marketed predicate device: Rapid ASPECTS (K200760) Device Description: Rapid Platform The Rapid platform is Software as a Medical Device (SaMD), which provides for the visualizat…
Ischemaview, Inc.2020—

Also cleared against K200760: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 3.6 years on median.
  • None of the 2 ancestors has a recall.
  • 2 other devices also cite its predicate K200760.

How does its category compare?

All POK devices

POK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · POK

5in 2025

2017: 12019: 12020: 22021: 22022: 12023: 12024: 62025: 52026 (partial year): 5
2007high 6 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · POK

119in 2025

2024: 161 days median2025: 119 days median2026 (partial year): 155 days median
2007high 161 (2024) · low 119 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · POK

No recall names POK since 2007.

Adverse event reports per year · POK

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2025

MAUDE reports naming product code POK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20171—00
20180—00
20191—00
20202—00
20212—01
20221—00
20231—00
2024616100
2025511900
202651550—

What is it indicated for?

Rapid ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characterization of brain tissue abnormalities using CT image data. The Software automatically registers images and segments and analyzes ASPECTS Regions of Interest (ROIs). Rapid ASPECTS extracts image data for the ROI(s) to provide analysis and computer analytics based on morphological characteristics. The imaging features are then…

Read the full statement (194 words)

Rapid ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characterization of brain tissue abnormalities using CT image data. The Software automatically registers images and segments and analyzes ASPECTS Regions of Interest (ROIs). Rapid ASPECTS extracts image data for the ROI(s) to provide analysis and computer analytics based on morphological characteristics. The imaging features are then synthesized by an artificial intelligence algorithm into a single ASPECT (Alberta Stroke Program Early CT) Score.

Rapid ASPECTS is indicated for evaluation of adult patients presenting for diagnostic imaging workup, for evaluation of extent of disease. Extent of disease refers to the number of ASPECTS regions affected which is reflected in the total score. This device provides information that may be useful in the characterization of early ischemic brain tissue injury for ischemic stroke patient (typically < 24 hours since last known well) during image interpretation following the standard of care. Rapid ASPECTS provides a comparative analysis to the ASPECTS standard of care radiologist assessment using the ASPECTS atlas definitions and atlas display including highlighted ROIs and numerical scoring. Rapid ASPECTS presents the original and annotated images for concurrent reads.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K232156: Rapid ASPECTS (v3).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K232156

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026