Brightheart · POK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer

Cleared on Nov 14, 2024 as substantially equivalent to K201555 (Ultromics, Ltd., 2020) after a 99-day review. Its family tree reaches back 9 generations to 1991. 2 later devices descend from it.

Decided
Nov 14, 2024
Review
99 days
Class
Class II
Product code
POK
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K913770 (1991). 16 ancestors in all. 2 later devices descend from it, 2 citing it directly.

  1. Root · 9 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 5 generations between
  3. 3 generations backK161959 ClearView cCADClearview Diagnostics, Inc. · 2016 · Recalled
  4. 2 generations backK190442 Koios DS for BreastKoios Medical, Inc. · 2019
  5. 1 generation backK201555 EchoGo ProUltromics, Ltd. · 2020
  6. This deviceK242342 Fetal EchoScanBrightheart · 2024
  7. Descendant · cites it directly · 1 of its ownK251071 Fetal EchoScan (v1.1)Brightheart · 2025
  8. Descendant · cites it directly · 0 of its ownK252294 Fetal EchoScan (v1.2)Brightheart · 2025
Show all 9 generations
  1. Root · 9 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 8 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 7 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 6 generations backK033400 Seno AdvantageGe Medical Systems W-400 · 2003 · Recalled
  5. 5 generations backK043216 Cadstream Version 4.0Confirma, Inc. · 2005
  6. 4 generations backK050846 B-Cad System, Version 1.0The Medipattern Corporation · 2005
  7. 3 generations backK161959 ClearView cCADClearview Diagnostics, Inc. · 2016 · Recalled
  8. 2 generations backK190442 Koios DS for BreastKoios Medical, Inc. · 2019
  9. 1 generation backK201555 EchoGo ProUltromics, Ltd. · 2020
  10. This deviceK242342 Fetal EchoScanBrightheart · 2024

Most influential descendants

Showing 2 of 2 · See all
  • K251071Fetal EchoScan (v1.1)Brightheart · 2025 · cites it directly1descendant
  • K252294Fetal EchoScan (v1.2)Brightheart · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−8K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−7K020483Advantage Workstation 4.1GE Medical Systems20022
−6K033400Seno AdvantageGe Medical Systems W-40020036
−5K043216Cadstream Version 4.0Confirma, Inc.2005—
−4K050846B-Cad System, Version 1.0The Medipattern Corporation2005—
−3K161959ClearView cCADClearview Diagnostics, Inc.20161
−2K190442Koios DS for BreastKoios Medical, Inc.2019—
−1K201555EchoGo ProUltromics, Ltd.2020—
0 (this device)K242342Fetal EchoScanBrightheart2024—
+1K251071Fetal EchoScan (v1.1)Brightheart2025—
+1K252294Fetal EchoScan (v1.2)Brightheart2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
200220
200310
200420
201710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202520
FIG. 1 — Lineage of K242342, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in POK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new POK device

  1. #1 K251071 Fetal EchoScan (v1.1)score 15.0 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K201555EchoGo Pro
Summary page 5
…CFR 892.2060 Regulatory Class: Class II Product Code: POK 3. PREDICATE DEVICE Predicate Device: Ultromics Ltd., EchoGo Pro [K201555] The predicate device has not been subject to a design-related recall. 4. DEVICE DESCRIPTION Fetal EchoScan is a clou…
Ultromics, Ltd.2020—

Also cleared against K201555: 3 other devices →

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K251071Fetal EchoScan (v1.1)Brightheart20251
K252294Fetal EchoScan (v1.2)Brightheart20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 9 companies; a new generation was cleared every 2.5 years on median.
  • 3 of the 16 ancestors have a recall of any class.
  • Of its descendants, K251071 (Brightheart, 2025) has gone furthest, with 1 descendant of its own.
  • 3 other devices also cite its predicate K201555.

How does its category compare?

All POK devices

POK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · POK

5in 2025

2017: 12019: 12020: 22021: 22022: 12023: 12024: 62025: 52026 (partial year): 5
2007high 6 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · POK

119in 2025

2024: 161 days median2025: 119 days median2026 (partial year): 155 days median
2007high 161 (2024) · low 119 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · POK

No recall names POK since 2007.

Adverse event reports per year · POK

1in 2021

2021: 1
2007high 1 (2021) · low 0 (2007)2025

MAUDE reports naming product code POK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20171—00
20180—00
20191—00
20202—00
20212—01
20221—00
20231—00
2024616100
2025511900
202651550—

What is it indicated for?

Fetal EchoScan is a machine learning-based computer-assisted diagnosis (CADx) software device indicated as an adjunct to fetal heart ultrasound examination in pregnant women aged 18 or older undergoing second-trimester anatomic ultrasound exams. When utilized by an interpreting physician, Fetal EchoScan provides information regarding the presence of any of the following suspicious radiographic findings: - overriding artery - septal defect at the cardiac…

Read the full statement (227 words)

Fetal EchoScan is a machine learning-based computer-assisted diagnosis (CADx) software device indicated as an adjunct to fetal heart ultrasound examination in pregnant women aged 18 or older undergoing second-trimester anatomic ultrasound exams.

When utilized by an interpreting physician, Fetal EchoScan provides information regarding the presence of any of the following suspicious radiographic findings:

- overriding artery

- septal defect at the cardiac crux

- abnormal relationship of the outflow tracts

- enlarged cardiothoracic ratio

- right ventricular to left ventricular size discrepancy

- tricuspid valve to mitral valve annular size discrepancy

- pulmonary valve to aortic valve annular size discrepancy

- cardiac axis deviation

Fetal EchoScan is to be used with cardiac fetal ultrasound video clips containing interpretable 4-chamber, left ventricular outflow tract, right ventricular outflow tract standard views.

Fetal EchoScan is intended for use as a concurrent reading aid for interpreting physicians (OB-GYN, MFM). It does not replace the role of the physician or of other diagnostic testing in the standard of care. When utilized by an interpreting physician, this device provides information that may be useful in rendering an accurate diagnosis regarding the potential presence of morphological abnormalities that might be suggestive of fetal congenital heart defects that may be useful in determining the need for additional exams.

Fetal EchoScan is not intended for use in multiple pregnancies, cases of heterotaxy, and postnatal ultrasound exams.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K242342: Fetal EchoScan.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242342

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026