Avicenna.Ai · POK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer
Cleared on Mar 15, 2024 as substantially equivalent to K200760 (Ischemaview, Inc., 2020) after a 168-day review. Its family tree reaches back 2 generations to 2017.
- Decided
- Mar 15, 2024
- Review
- 168 days
- Class
- Class II
- Product code
- POK
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to DEN170022 (2017). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in POK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new POK device
- #1 K242342 Fetal EchoScanscore 16.7 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K200760 | Rapid ASPECTSSummary page 4…y equivalent to the following predicate device with regard to indications for use, performance, and technological characteristics: 510(k): K200760 Trade Name: Rapid ASPECTS Manufacturer: ISchemaView Inc. Classifica… | 2020 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 3.7 years on median.
- None of the 2 ancestors has a recall.
- 2 other devices also cite its predicate K200760.
How does its category compare?
All POK devicesPOK Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · POK
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · POK
119in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · POK
No recall names POK since 2007.
Adverse event reports per year · POK
1in 2021
MAUDE reports naming product code POK, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 1 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 1 | — | 0 | 0 |
| 2020 | 2 | — | 0 | 0 |
| 2021 | 2 | — | 0 | 1 |
| 2022 | 1 | — | 0 | 0 |
| 2023 | 1 | — | 0 | 0 |
| 2024 | 6 | 161 | 0 | 0 |
| 2025 | 5 | 119 | 0 | 0 |
| 2026 | 5 | 155 | 0 | — |
What is it indicated for?
CINA-ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characterization of brain tissue abnormalities using CT image data. The Software automatically reorients images, segments and analyzes ASPECTS Regions of lnterest (ROIs). CINA-ASPECTS extracts image data for the ROI(s) to provide analysis and computer analytics based on morphological characteristics. The imaging features are then…
Read the full statement (350 words)
CINA-ASPECTS is a computer-aided diagnosis (CADx) software device used to assist the clinician in the assessment and characterization of brain tissue abnormalities using CT image data.
The Software automatically reorients images, segments and analyzes ASPECTS Regions of lnterest (ROIs). CINA-ASPECTS extracts image data for the ROI(s) to provide analysis and computer analytics based on morphological characteristics. The imaging features are then synthesized by an artificial intelligence algorithm into a single ASPECT (Alberta Stroke Program Early CT) Score.
CINA-ASPECTS is indicated for evaluation of patients presenting for diagnostic imaging workup with known MCA or ICA occlusion, for evaluation of extent of disease. Extent of disease refers to the number of ASPECTS regions affected which is reflected in the total score. This device provides information that may be useful in the characterization of early ischemic (acute) brain tissue injury during image interpretation.
CINA-ASPECTS provides a comparative analysis to the ASPECTS standard of care radiologist assessment using the ASPECTS region definitions and highlighting ROIs and numerical scoring.
Limitations:
1. CINA-ASPECT is not intended for primary interpretation of CT images. It is used to assist physician evaluation.
2. CINA-ASPECT has been validated in patients with known MCA or ICA unilateral occlusion prior to ASPECTS scoring.
3. CINA-ASPECTS is not suitable for use on brain scans displaying neurological pathologies other than acute stroke, such as tumors or abscesses, traumatic brain injuries, hemorrhagic transformation and hematoma.
4. Use of CINA-ASPECT in clinical settings other than brain ischemia within 12 hours from time last known well, caused by known ICA or MCA occlusions has not been tested.
5. CINA-ASPECTS has only been validated and is intended to be used in patient populations aged over 21.
6. CINA-ASPECTS has been validated and is intended to be used with images acquired with Canon Medical Systems Corporation, GE Healthcare, Philips Healthcare and Siemens Healthineers scanners.
Contraindications/Exclusions/Cautions:
▪ Patient motion: Excessive patient motion leading to artifacts that make the scan technically inadequate.
▪ Important streak artifacts and noisy images: Presence of important streak artifact and significant noise within the NCCT images that make the scan technically inadequate.
▪ Hemorrhagic Transformation, Hematoma.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K233342 · printed Nov 6, 2026
Cite this page
510(k) Report. “K233342: Cina-Aspects.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K233342