510(k) Report

510(k) · Cleared

Cleared

Cina-VCF

K240612510(k) TraditionalCleared May 31, 202487-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Avicenna.Ai · QFM Radiological Computer-Assisted Prioritization Software For Lesions

Cleared on May 31, 2024 as substantially equivalent to K222692 (Aidoc Medical, Ltd., 2022) after an 87-day review. Its family tree reaches back 4 generations to 2018.

Decided
May 31, 2024
Review
87 days
Class
Class II
Product code
QFM
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to DEN170073 (2018). No later device cites it as a predicate yet.

  1. Root · 4 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 3 generations backK183285 cmTriageCuremetrix, Inc. · 2019
  3. 2 generations backK192901 HealthVCFZebra Medical Vision, Ltd. · 2020
  4. 1 generation backK222692 BriefCaseAidoc Medical, Ltd. · 2022
  5. This deviceK240612 Cina-VCFAvicenna.Ai · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4DEN170073ContaCTViz.Al, Inc.2018—
−3K183285cmTriageCuremetrix, Inc.2019—
−2K192901HealthVCFZebra Medical Vision, Ltd.2020—
−1K222692BriefCaseAidoc Medical, Ltd.2022—
0 (this device)K240612Cina-VCFAvicenna.Ai2024—
FIG. 1 — Lineage of K240612, 2018–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QFM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QFM device

  1. #1 K211733 Lunit INSIGHT CXR Triagescore 21.2 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K222692BriefCase
Summary page 4
…y equivalent to the following predicate device with regard to indications for use, performance, and technological characteristics: 510(k): K222692 Trade Name: BriefCase Manufacturer: Aidoc Medical Vision Ltd. Class…
Aidoc Medical, Ltd.2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 5 companies; a new generation was cleared every 1.5 years on median.
  • None of the 4 ancestors has a recall.

How does its category compare?

All QFM devices

QFM Radiological Computer-Assisted Prioritization Software For Lesions: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QFM

3in 2025

2019: 42020: 42021: 52022: 92023: 82024: 62025: 32026 (partial year): 2
2007high 9 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QFM

100in 2025

2019: 97 days median2020: 172 days median2021: 187 days median2022: 121 days median2023: 206 days median2024: 192 days median2025: 100 days median
2007high 206 (2023) · low 97 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QFM

No recall names QFM since 2007.

Adverse event reports per year · QFM

No MAUDE report names QFM since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
201949700
2020417200
2021518700
2022912100
2023820600
2024619200
2025310000
20262—0—

What is it indicated for?

CINA-VCEF is a radiological computer aided triage and notification software indicated for use in patients aged 50 years and over undergoing non-enhanced or contrast-enhanced CT scans which include the chest and/or abdomen. The device is intended to assist hospital networks and appropriately trained medical specialists within the standard-of-care bone health setting in workflow triage by flagging and communication of suspected positive cases of Vertebral…

Read the full statement (159 words)

CINA-VCEF is a radiological computer aided triage and notification software indicated for use in patients aged 50 years and over undergoing non-enhanced or contrast-enhanced CT scans which include the chest and/or abdomen.

The device is intended to assist hospital networks and appropriately trained medical specialists within the standard-of-care bone health setting in workflow triage by flagging and communication of suspected positive cases of Vertebral Compression Fractures (VCF) findings.

CINA-VCF uses an artificial intelligence algorithm to analyze images and highlight cases with detected findings on a standalone application in parallel to the ongoing standard of care image interpretation. The device does not alter the original medical image, and it is not intended to be used as a diagnostic device.

The results of CINA-VCF are intended to be used in conjunction with other patient information and based on professional judgment to assist with triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K240612: Cina-VCF.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K240612

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026