510(k) Report

510(k) · Cleared

Cleared

CINA-iPE

K233968510(k) TraditionalCleared Mar 13, 202489-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Avicenna.Ai · QAS Radiological Computer-Assisted Triage And Notification Software

Cleared on Mar 13, 2024 as substantially equivalent to K213886 (Aidoc Medical, Ltd., 2022) after an 89-day review. Its family tree reaches back 6 generations to 2018.

Decided
Mar 13, 2024
Review
89 days
Class
Class II
Product code
QAS
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to DEN170073 (2018). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 6 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 5 generations backK180647 BriefCaseAidoc Medical, Ltd. · 2018
  3. 4 generations backK190072 BriefCaseAidoc Medical, Ltd. · 2019
  4. 3 generations backK201020 BriefCaseAidoc Medical, Ltd. · 2020
  5. 2 generations backK203508 BriefCaseAidoc Medical, Ltd. · 2020
  6. 1 generation backK213886 BriefCaseAidoc Medical, Ltd. · 2022
  7. This deviceK233968 CINA-iPEAvicenna.Ai · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6DEN170073ContaCTViz.Al, Inc.2018—
−5K180647BriefCaseAidoc Medical, Ltd.2018—
−4K190072BriefCaseAidoc Medical, Ltd.2019—
−3K201020BriefCaseAidoc Medical, Ltd.2020—
−2K203508BriefCaseAidoc Medical, Ltd.2020—
−1K213886BriefCaseAidoc Medical, Ltd.2022—
0 (this device)K233968CINA-iPEAvicenna.Ai2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201920
202010
FIG. 1 — Lineage of K233968, 2018–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAS device

  1. #1 K203508 BriefCasescore 25.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K213886BriefCase
Summary page 4
…equivalent to the following predicate device with regard to indications for use, performance, and technological characteristics: 510(k): K213886 Trade Name: BriefCase Manufacturer: Aidoc Medical, Ltd. Classific…
Aidoc Medical, Ltd.2022—

Also cleared against K213886: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 3 companies; a new generation was cleared every 1.3 years on median.
  • None of the 9 ancestors has a recall.
  • 1 other device also cites its predicate K213886.

How does its category compare?

All QAS devices

QAS Radiological Computer-Assisted Triage And Notification Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QAS

15in 2025

2018: 32019: 52020: 122021: 52022: 152023: 112024: 122025: 152026 (partial year): 11
2007high 15 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAS

101in 2025

2019: 111 days median2020: 112 days median2021: 86 days median2022: 116 days median2023: 98 days median2024: 136 days median2025: 101 days median2026 (partial year): 104 days median
2007high 136 (2024) · low 86 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QAS

No recall names QAS since 2007.

Adverse event reports per year · QAS

No MAUDE report names QAS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20183—00
2019511100
20201211200
202158600
20221511600
2023119800
20241213600
20251510100
2026111040—

What is it indicated for?

CINA-iPE is a radiological computer-aided triage and notification software indicated for use in patients undergoing contrast-enhanced CT scans (not dedicated CTPA protocol) for other clinical indications than pulmonary embolism suspicion, including at least a part of the lung. The device is intended to assist hospital networks and appropriately trained radiologists in workflow triage by flagging and communicating suspected positive findings for…

Read the full statement (220 words)

CINA-iPE is a radiological computer-aided triage and notification software indicated for use in patients undergoing contrast-enhanced CT scans (not dedicated CTPA protocol) for other clinical indications than pulmonary embolism suspicion, including at least a part of the lung. The device is intended to assist hospital networks and appropriately trained radiologists in workflow triage by flagging and communicating suspected positive findings for incidental Pulmonary Embolism (iPE). The device is indicated for adults and transitional adolescents (18 to 21 years old but treated as adults).

CINA-iPE uses an artificial intelligence algorithm to analyze images and highlight cases with detected incidental PE on a standalone application in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected incidental PE findings.The device is not designed to detect PE in subsegmental arteries.

Notifications include compressed preview images that are meant for informational purposes only and are not intended for diagnostic use beyond notification. The device does not alter the original medical image, and it is not intended to be used as a diagnostic device.

The results of CINA-iPE are intended to be used in conjunction with other patient information and based on their professional judgment, to assist with triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233968: CINA-iPE.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K233968

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026