510(k) Report

510(k) · Cleared

Cleared

Image Management V15

K240822510(k) TraditionalCleared Apr 24, 202430-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems Technologies · LLZ System, Image Processing, Radiological

Cleared on Apr 24, 2024 as substantially equivalent to K110919 (Carestream Health, Inc., 2011) after a 30-day review. Its family tree reaches back 6 generations to 1996.

Decided
Apr 24, 2024
Review
30 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K954678 (1996). 9 ancestors in all, the oldest K941223 (1994). No later device cites it as a predicate yet.

  1. Root · 6 generations backK954678 Pro VisionAlgotec Systems, Ltd. · 1996
  2. 5 generations backK980648 Pro VisionAlgotec Systems, Ltd. · 1998
  3. 4 generations backK992654 Plug 'N View 3D, Version 1.0Voxar Limited · 1999
  4. 3 generations backK020546 Fusion 7DMirada Solutions, Ltd. · 2002
  5. 2 generations backK083673 Carestream Pacs, Model Carestream Pacs ViiCarestream Health, Inc. · 2008
  6. 1 generation backK110919 Carestream PacsCarestream Health, Inc. · 2011 · Recalled
  7. This deviceK240822 Image Management V15Philips Medical Systems Technologies · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K954678Pro VisionAlgotec Systems, Ltd.1996—
−5K980648Pro VisionAlgotec Systems, Ltd.1998—
−4K992654Plug 'N View 3D, Version 1.0Voxar Limited1999—
−3K020546Fusion 7DMirada Solutions, Ltd.2002—
−2K083673Carestream Pacs, Model Carestream Pacs ViiCarestream Health, Inc.2008—
−1K110919Carestream PacsCarestream Health, Inc.201150
0 (this device)K240822Image Management V15Philips Medical Systems Technologies2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199810
200110
FIG. 1 — Lineage of K240822, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K110919Carestream Pacs
Summary page 5
…stem, Image Processing, Radiological Product Code LLZ Classification 21 CFR 892.2050 Predicate Device CARESTREAM PACS (K110919) Reference Devices Carestream Vue PACS (K122523) Carestream Vue PACS (K170580)…
Carestream Health, Inc.201150
†K122523Carestream Vue PacsCarestream Health, Inc.2012—
†K170580Carestream Vue PACSCarestream Health, Inc.2017—
†K151774CARESTREAM Vue MotionCarestream Health, Inc.20151

Also cleared against K110919: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 5 companies; a new generation was cleared every 2.8 years on median.
  • 2 of the 9 ancestors have a recall of any class.
  • 1 other device also cites its predicate K110919.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

Image Management is intended to provide complete and scalable local and wide area PACS solutions for hospital and related institutions/sites, which will archive, distribute, retrieve, process and display medical images and data from hospital medical imaging and information systems. The device contains clinical applications that assist the processing, analyzing and comparing of medical images. It is a single device that integrates the review, dictation…

Read the full statement (171 words)

Image Management is intended to provide complete and scalable local and wide area PACS

solutions for hospital and related institutions/sites, which will archive, distribute, retrieve, process

and display medical images and data from hospital medical imaging and information systems.

The device contains clinical applications that assist the processing, analyzing and comparing of

medical images. It is a single device that integrates the review, dictation and reporting tools to create

a productive work environment for the radiologists and physicians.

The Image Management viewers are used for patient exam management by clinicians in order to

access and display patient data, medical reports, medical data and medical images from different

modalities including but not limited to CR, DR, CT, MR, NM, ECG, US, MG*, DBT*, OP and OPT.

The device provides wireless and portable access to medical images for remote reading or referral

purposes from web browsers using current standard HTML.

*For primary interpretation and review of mammography images, only use display hardware that is

specifically designed for and cleared by FDA for mammography.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K240822: Image Management V15.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K240822

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026