510(k) Report

510(k) · Cleared

Cleared

Hood (DH-083ST)

K242779510(k) SpecialCleared Oct 11, 202428-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fujifilm Corporation · FDS Gastroscope And Accessories, Flexible/Rigid

Cleared on Oct 11, 2024 as substantially equivalent to K232314 (FUJIFILM Healthcare Americas Corporation, 2023) after a 28-day review. Its family tree reaches back 6 generations to 2000.

Decided
Oct 11, 2024
Review
28 days
Class
Class II
Product code
FDS
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K993704 (2000). 9 ancestors in all, the oldest K944759 (1995). No later device cites it as a predicate yet.

  1. Root · 6 generations backK993704 Gastro-Intestinal System EN-410WMFujinon, Inc. · 2000
  2. 5 generations backK040048 Fujinon Double Balloon Enteroscopy SystemFujinon, Inc. · 2004
  3. 4 generations backK090116 Fujinon Colonoscope for Double Balloon Enterscopy System Model…Fujinon, Inc. · 2009
  4. 3 generations backK143556 Fujifilm Double Balloon Endoscopes Models EN-530T and EN-580TFujifilm Medical Systems U.S.A, Inc. · 2015
  5. 2 generations backK162749 FUJIFILM Hood Models DH-28GR, DH-29CR and DH-30CRFujifilm Medical Systems U.S.A, Inc. · 2017
  6. 1 generation backK232314 Hood (DH-106STL, DH-116STL, DH-126STL, DH-096ST)FUJIFILM Healthcare Americas Corporation · 2023
  7. This deviceK242779 Hood (DH-083ST)Fujifilm Corporation · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K993704Gastro-Intestinal System EN-410WMFujinon, Inc.2000—
−5K040048Fujinon Double Balloon Enteroscopy SystemFujinon, Inc.2004—
−4K090116Fujinon Colonoscope for Double Balloon Enterscopy System Model, EC-450B15Fujinon, Inc.2009—
−3K143556Fujifilm Double Balloon Endoscopes Models EN-530T and EN-580TFujifilm Medical Systems U.S.A, Inc.2015—
−2K162749FUJIFILM Hood Models DH-28GR, DH-29CR and DH-30CRFujifilm Medical Systems U.S.A, Inc.2017—
−1K232314Hood (DH-106STL, DH-116STL, DH-126STL, DH-096ST)FUJIFILM Healthcare Americas Corporation2023—
0 (this device)K242779Hood (DH-083ST)Fujifilm Corporation2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199520
200410
FIG. 1 — Lineage of K242779, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FDS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FDS device

  1. #1 K251708 EvoEndo Single-Use Endoscopy Systemscore 16.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K232314Hood (DH-106STL, DH-116STL, DH-126STL, DH-096ST)
Summary page 5
…876.1500 Product Code(s) FDS I Legally Marketed Predicate Devices 21 CFR 807.92(a)(3) Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K232314 Hood models DH-096ST FDS Device Description Summary 21 CFR 807.92(a)(4) A.Intended Use This hood is intended to be used in combi…
FUJIFILM Healthcare Americas Corporation2023—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 4.9 years on median.
  • 3 of the 9 ancestors have a recall of any class.

How does its category compare?

All FDS devices

FDS Gastroscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · FDS

8in 2025

2007: 22010: 12011: 12012: 32013: 22014: 22015: 22016: 12017: 12018: 62019: 52020: 22021: 52022: 22023: 32024: 52025: 82026 (partial year): 7
2007high 8 (2025) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FDS

211in 2025

2012: 181 days median2018: 167 days median2019: 175 days median2021: 78 days median2023: 133 days median2024: 220 days median2025: 211 days median2026 (partial year): 164 days median
2007high 220 (2024) · low 78 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FDS

2in 2024

2013: 12016: 12020: 22024: 2
2007high 2 (2020) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FDS

18,905in 2025

2007: 272008: 112009: 212010: 452011: 362012: 352013: 82014: 232015: 292016: 1082017: 1782018: 3042019: 1,3762020: 6012021: 1,7552022: 6,2162023: 9,8742024: 9,2582025: 18,905
2007high 18,905 (2025) · low 8 (2013)2025

MAUDE reports naming product code FDS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—027
20080—011
20090—021
20101—045
20111—036
20123181035
20132—18
20142—023
20152—029
20161—1108
20171—0178
201861670304
2019517501,376
20202—2601
202157801,755
20222—06,216
2023313309,874
2024522029,258
20258211018,905
202671640—

What is it indicated for?

This hood is intended to be used in combination with compatible endoscopes to maintain the field of view during endoscopic procedures such as mucosal resection.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K242779: Hood (DH-083ST).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K242779

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026