510(k) Report

510(k) · Cleared

Cleared

Lumys (V1)

K243069510(k) TraditionalCleared May 2, 2025217-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intradys · LLZ System, Image Processing, Radiological

Cleared on May 2, 2025 as substantially equivalent to K221796 (Abys Medical, 2022) after a 217-day review. Its family tree reaches back 15 generations to 1991.

Decided
May 2, 2025
Review
217 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 15 generations to K913770 (1991). 169 ancestors in all, the oldest K890348 (1989). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2021: 2 other ancestors2018: 1 other ancestor2014: 2 other ancestors2019: 1 other ancestor2017: 2 other ancestors2015: 2 other ancestors2011: 3 other ancestors2008: 3 other ancestors2009: 1 other ancestor2007: 3 other ancestors2006: 6 other ancestors2004: 15 other ancestors2013: 1 other ancestor2005: 4 other ancestors2003: 13 other ancestors2002: 11 other ancestors2001: 19 other ancestors2000: 11 other ancestors1999: 5 other ancestors1998: 9 other ancestors1997: 7 other ancestors1994: 6 other ancestors1993: 5 other ancestors2010: 1 other ancestor1996: 8 other ancestors1995: 6 other ancestors1991: 4 other ancestors1990: 1 other ancestor1989: 2 other ancestorsK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991K960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002×2: 2 generations cleared close together, K032748 (2003), K040305 (2004) K043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK072821 · Vitrea 4DCT · Vital Images, Inc. · 2008 · recalledK132853 · Novapacs · Novarad Corp. · 2014 · recalledK160371 · NovaPACS · Novarad Corporation · 2016K171754 · NovaPACS · Novarad Corporation · 2017 · recalledK221796 · Cyware 4H and Cysart 4H · Abys Medical · 20221990200020102020
Other ancestors, by generation 2 generations back: 4 other ancestors3 generations back: 7 other ancestors4 generations back: 7 other ancestors5 generations back: 17 other ancestors6 generations back: 24 other ancestors7 generations back: 29 other ancestors8 generations back: 26 other ancestors9 generations back: 21 other ancestors10 generations back: 12 other ancestors11 generations back: 4 other ancestors12 generations back: 2 other ancestors13 generations back: 1 other ancestor K221796 · Cyware 4H and Cysart 4H · Abys Medical · 2022K171754 · NovaPACS · Novarad Corporation · 2017 · recalledK160371 · NovaPACS · Novarad Corporation · 2016K132853 · Novapacs · Novarad Corp. · 2014 · recalledK072821 · Vitrea 4DCT · Vital Images, Inc. · 2008 · recalledK071331 · Vitrea Version 4.0 · Vital Images, Inc. · 2007 · recalledK061624 · Vitrea, Version 3.9 · Vital Images, Inc. · 2006 · recalledK052632 · VITREA2 Version 3.8 Medical Image Processing Software · Vital Images, Inc. · 2005 · recalledK043333 · VITREA2, Version 3.7 Medical Image Processing System · Vital Images, Inc. · 2004 · recalledK040305 · VITREA2 Version 3.5 · Vital Images, Inc. · 2004K032748 · VITREA2, Version 3.4 Medical Image Processing Software · Vital Images, Inc. · 2003 · recalledK023003 · Imagechecker-CT Workstation · R2 Technology, Inc. · 2002K020483 · Advantage Workstation 4.1 · GE Medical Systems · 2002 · recalledK960613 · GE Advantage Windows Review Workstation · GE Medical Systems · 1996K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 1991−15−10−50
  1. Root · 15 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 11 generations between
  3. 3 generations backK160371 NovaPACSNovarad Corporation · 2016
  4. 2 generations backK171754 NovaPACSNovarad Corporation · 2017 · Recalled
  5. 1 generation backK221796 Cyware 4H and Cysart 4HAbys Medical · 2022
  6. This deviceK243069 Lumys (V1)Intradys · 2025
Show all 15 generations
  1. Root · 15 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 14 generations backK960613 GE Advantage Windows Review WorkstationGE Medical Systems · 1996
  3. 13 generations backK020483 Advantage Workstation 4.1GE Medical Systems · 2002 · Recalled
  4. 12 generations backK023003 Imagechecker-CT WorkstationR2 Technology, Inc. · 2002
  5. 11 generations backK032748 VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc. · 2003 · Recalled
  6. 10 generations backK040305 VITREA2 Version 3.5Vital Images, Inc. · 2004
  7. 9 generations backK043333 VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc. · 2004 · Recalled
  8. 8 generations backK052632 VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc. · 2005 · Recalled
  9. 7 generations backK061624 Vitrea, Version 3.9Vital Images, Inc. · 2006 · Recalled
  10. 6 generations backK071331 Vitrea Version 4.0Vital Images, Inc. · 2007 · Recalled
  11. 5 generations backK072821 Vitrea 4DCTVital Images, Inc. · 2008 · Recalled
  12. 4 generations backK132853 NovapacsNovarad Corp. · 2014 · Recalled
  13. 3 generations backK160371 NovaPACSNovarad Corporation · 2016
  14. 2 generations backK171754 NovaPACSNovarad Corporation · 2017 · Recalled
  15. 1 generation backK221796 Cyware 4H and Cysart 4HAbys Medical · 2022
  16. This deviceK243069 Lumys (V1)Intradys · 2025
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−15K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−14K960613GE Advantage Windows Review WorkstationGE Medical Systems1996—
−13K020483Advantage Workstation 4.1GE Medical Systems20022
−12K023003Imagechecker-CT WorkstationR2 Technology, Inc.2002—
−11K032748VITREA2, Version 3.4 Medical Image Processing SoftwareVital Images, Inc.20032
−10K040305VITREA2 Version 3.5Vital Images, Inc.2004—
−9K043333VITREA2, Version 3.7 Medical Image Processing SystemVital Images, Inc.20041
−8K052632VITREA2 Version 3.8 Medical Image Processing SoftwareVital Images, Inc.20052
−7K061624Vitrea, Version 3.9Vital Images, Inc.20061
−6K071331Vitrea Version 4.0Vital Images, Inc.20071
−5K072821Vitrea 4DCTVital Images, Inc.20081
−4K132853NovapacsNovarad Corp.20142
−3K160371NovaPACSNovarad Corporation2016—
−2K171754NovaPACSNovarad Corporation20171
−1K221796Cyware 4H and Cysart 4HAbys Medical2022—
0 (this device)K243069Lumys (V1)Intradys2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198920
199010
199140
199350
199460
199560
199680
199770
199890
199950
2000110
2001190
2002110
2003130
2004150
200540
200660
200730
200830
200910
201010
201130
201310
201420
201520
201720
201810
201910
202120
FIG. 1 — Lineage of K243069, 1991–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K221796Cyware 4H and Cysart 4H
Summary page 5
…mber: 892.2050 Product Code(s): LLZ Legally Marketed Predicate Devices Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K221796 Cysware 4H and Cysart 4H LLZ Device Description Summary LUMYS is a data visualiz…
Abys Medical2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 34 years and passes through 8 companies; a new generation was cleared every 11 months on median.
  • 46 of the 169 ancestors have a recall of any class.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

LUMYS is intended for use as a software interface and image segmentation system, which is used to carry out pre-surgical planning tasks. LUMYS is intended to be used by clinicians with appropriate clinical judgement. LUMYS is a medical display software intended for 3D image visualization and image interaction. The stereoscopic 3D images are generated from 3D volumetric data acquired from a CT scan source. The device is intended to provide visual…

Read the full statement (190 words)

LUMYS is intended for use as a software interface and image segmentation system, which is used to carry out pre-surgical planning tasks. LUMYS is intended to be used by clinicians with appropriate clinical judgement.

LUMYS is a medical display software intended for 3D image visualization and image interaction. The stereoscopic 3D images are generated from 3D volumetric data acquired from a CT scan source. The device is intended to provide visual information to be used by clinicians with appropriate clinical judgement for analysis of surgical options, and the intraoperative display of the images. The primary surgeon wears a Microsoft Hololens™ Head Mounted Display (HMD) and consults with external users who can perform pre-surgical tasks such as annotating 3D images, uploading files and speaking with the surgeon. The surgeon must cease communication once surgery begins.

LUMYS is intended to be used as an adjunct to the interpretation of images performed using diagnostic imaging systems and is not intended for primary diagnosis. LUMYS is intended to be used as a reference display consultation software, which assists the clinician with appropriate clinical judgement who is responsible for making all final patient management decisions.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K243069: Lumys (V1).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K243069

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026