510(k) · Cleared
CleareduWS-Angio Basic
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shanghai United Imaging Healthcare Co., Ltd. · LLZ System, Image Processing, Radiological
Cleared on May 12, 2025 as substantially equivalent to K230955 (Siemens Medical Solutions USA, Inc., 2023) and 2 other predicates after a 168-day review. Its family tree reaches back 16 generations to 1993. 4 of the 275 devices in its family, counting itself, have a Class I recall.
- Decided
- May 12, 2025
- Review
- 168 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 16 generations to K926514 (1993). 274 ancestors in all, the oldest K837107 (1983). No later device cites it as a predicate yet. 4 of the 275 devices in this family, counting this one, have a Class I recall.
- Root · 16 generations backK926514 Endoscopic Ultrasound System Type 20Olympus Corp. · 1993 · Recalled
- 12 generations between
- 3 generations backK151780 CAAS WorkstationPie Medical Imaging BV · 2016
- 2 generations backK180019 CAAS WorkstationPie Medical Imaging BV · 2018
- 1 generation backK232147 CAAS WorkstationPie Medical Imaging BV · 2024
- This deviceK243632 uWS-Angio BasicShanghai United Imaging Healthcare Co., Ltd. · 2025
Show all 16 generations
- Root · 16 generations backK926514 Endoscopic Ultrasound System Type 20Olympus Corp. · 1993 · Recalled
- 15 generations backK951994 Olympus EU-M30 Endoscopic Ultrasound CenterOlympus America, Inc. · 1996
- 14 generations backK982323 Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary…Olympus America, Inc. · 1998
- 13 generations backK042438 Superdimension/BronchusSuperdimension, Ltd. · 2004 · Recalled
- 12 generations backK052260 Superdimension/Bronchus 4.1Superdimension, Ltd. · 2005 · Recalled
- 11 generations backK052852 Superdimension/Bronchus PremiumSuperdimension, Ltd. · 2005 · Recalled
- 10 generations backK062315 Superdimension/Bronchus Premium 2Superdimension, Ltd. · 2006 · Recalled
- 9 generations backK071473 Modification to Superdimension/Bronchus Premium 2Superdimension, Ltd. · 2007
- 8 generations backK080271 Inreach SystemSuperdimension, Ltd. · 2008
- 7 generations backK081379 Modification to Inreach SystemSuperdimension, Ltd. · 2008
- 6 generations backK083745 The IC-Pro System, Model Version 3.2Paieon, Inc. · 2009
- 5 generations backK100292 Caas Qva 3D, Caas Qca 3DPie Medical Imaging BV · 2010
- 4 generations backK133993 Caas WorkstationPie Medical Imaging · 2014
- 3 generations backK151780 CAAS WorkstationPie Medical Imaging BV · 2016
- 2 generations backK180019 CAAS WorkstationPie Medical Imaging BV · 2018
- 1 generation backK232147 CAAS WorkstationPie Medical Imaging BV · 2024
- This deviceK243632 uWS-Angio BasicShanghai United Imaging Healthcare Co., Ltd. · 2025
Class I recalls in this family
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −16 | K926514 | Endoscopic Ultrasound System Type 20 | Olympus Corp. | 1993 | 1 |
| −15 | K951994 | Olympus EU-M30 Endoscopic Ultrasound Center | Olympus America, Inc. | 1996 | — |
| −14 | K982323 | Olympus UM 2R/3R Ultrasonic Probes and Associated Ancillary Equipment, for… | Olympus America, Inc. | 1998 | — |
| −13 | K042438 | Superdimension/Bronchus | Superdimension, Ltd. | 2004 | 1 |
| −12 | K052260 | Superdimension/Bronchus 4.1 | Superdimension, Ltd. | 2005 | 2 |
| −11 | K052852 | Superdimension/Bronchus Premium | Superdimension, Ltd. | 2005 | 1 |
| −10 | K062315 | Superdimension/Bronchus Premium 2 | Superdimension, Ltd. | 2006 | 1 |
| −9 | K071473 | Modification to Superdimension/Bronchus Premium 2 | Superdimension, Ltd. | 2007 | — |
| −8 | K080271 | Inreach System | Superdimension, Ltd. | 2008 | — |
| −7 | K081379 | Modification to Inreach System | Superdimension, Ltd. | 2008 | — |
| −6 | K083745 | The IC-Pro System, Model Version 3.2 | Paieon, Inc. | 2009 | — |
| −5 | K100292 | Caas Qva 3D, Caas Qca 3D | Pie Medical Imaging BV | 2010 | — |
| −4 | K133993 | Caas Workstation | Pie Medical Imaging | 2014 | — |
| −3 | K151780 | CAAS Workstation | Pie Medical Imaging BV | 2016 | — |
| −2 | K180019 | CAAS Workstation | Pie Medical Imaging BV | 2018 | — |
| −1 | K232147 | CAAS Workstation | Pie Medical Imaging BV | 2024 | — |
| 0 (this device) | K243632 | uWS-Angio Basic | Shanghai United Imaging Healthcare Co., Ltd. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1983 | 1 | 0 |
| 1987 | 1 | 0 |
| 1988 | 3 | 0 |
| 1989 | 3 | 0 |
| 1990 | 1 | 0 |
| 1991 | 8 | 0 |
| 1992 | 4 | 0 |
| 1993 | 4 | 0 |
| 1994 | 6 | 0 |
| 1995 | 13 | 0 |
| 1996 | 10 | 0 |
| 1997 | 11 | 0 |
| 1998 | 15 | 0 |
| 1999 | 9 | 0 |
| 2000 | 15 | 0 |
| 2001 | 23 | 0 |
| 2002 | 19 | 0 |
| 2003 | 17 | 1 |
| 2004 | 24 | 0 |
| 2005 | 12 | 0 |
| 2006 | 14 | 0 |
| 2007 | 11 | 1 |
| 2008 | 6 | 0 |
| 2009 | 5 | 0 |
| 2010 | 3 | 1 |
| 2011 | 5 | 0 |
| 2012 | 3 | 1 |
| 2013 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 2 | 0 |
| 2017 | 2 | 0 |
| 2018 | 2 | 0 |
| 2019 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
4 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K230955 | syngo Application SoftwareSummary page 5…Product Code: LLZ Regulation Number: 21 CFR 892.2050 Review Panel: Radiology 4. Identification of Predicate Device(s) Predicate Device 510(k) Number: K230955 Device Name: Syngo Application Software Secondary Predicate Device#1 510(k) Number: K183170… | 2023 |
| * | K183170 | uWS-CTSummary page 5…of Predicate Device(s) Predicate Device 510(k) Number: K230955 Device Name: Syngo Application Software Secondary Predicate Device#1 510(k) Number: K183170 Page 1 of 3 Shanghai United Imaging Healthcare Co., Ltd. T… | 2019 |
| * | K232147 | CAAS WorkstationSummary page 6…care Co., Ltd. T e l : +86 (21) 67076888 Fax:+86 (21) 67076889 www.united-imaging.com Device Name: uWS-CT Secondary Predicate Device#2 510(k) Number: K232147 Device Name: CAAS Workstation 5. Device Description uWS-Angio Basic is an image processing software that matches the us… | 2024 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (4 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K121434Software Syngo MR D13A for the Magnetom Systems Aera/Skyra/Avanto/VerioSiemens Medi Cal Solutions, Inc. · 2012 · 4 generations back · ◆ in the 2012 ancestors bar of FIG. 12 Class I recalls
- K101347Magnetom Aera; Magnetom SkyraSiemens Medical Solutions USA, Inc. · 2010 · 6 generations back · ◆ in the 2010 ancestors bar of FIG. 12 Class I recalls
- K072237Magnetom VerioSiemens Medical Solutions USA, Inc. · 2007 · 6 generations back · ◆ in the 2007 ancestors bar of FIG. 11 Class I recall
- K023984Modification to Olympus Bronchoscopes BF-40 Series, BF-240 Series, and BF-160 SeriesThe Olympus Optical Co. · 2003 · 14 generations back · ◆ in the 2003 ancestors bar of FIG. 114 Class I recalls
What does this lineage say?
- The line of descent spans 32 years and passes through 7 companies; a new generation was cleared every 1.2 years on median.
- 63 of the 274 ancestors have a recall of any class; 4 have a Class I recall.
- 3 other devices also cite its predicate K230955.
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2025, this device’s year, is highlighted.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
uWS-Angio Basic is intended to display and process XA (X-Ray Angiographic), CT (Computed Tomography), and MR (Magnetic Resonance) images that comply with the DICOM3.0 protocol.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K243632 · printed Nov 6, 2026
Cite this page
510(k) Report. “K243632: uWS-Angio Basic.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K243632
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026