510(k) Report

510(k) · Cleared

Cleared

BioSieve Multi-Drug Urine Test Panel;BioSieve Multi-Drug Urine Home Test Panel

K261280510(k) TraditionalCleared May 22, 202635-day reviewClass II21 CFR 862.3100

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vivachek Biotech (Hangzhou) Co., Ltd. · NFT Test, Amphetamine, Over The Counter

Cleared on May 22, 2026 as substantially equivalent to K233062 (Vivachek Biotech (Hangzhou) Co., Ltd., 2023) after a 35-day review. Its family tree reaches back 9 generations to 1995.

Decided
May 22, 2026
Review
35 days
Class
Class II
Product code
NFT
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K945610 (1995). 30 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 9 generations backK945610 Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM)…Princeton BioMeditech Corp. · 1995
  2. 5 generations between
  3. 3 generations backK182701 Wondfo T-Cup Multi-Drug Urine Test CupGuangzhou Wondfo Biotech Co., Ltd. · 2018 · Recalled
  4. 2 generations backK202567 Wondfo T-Dip Multi-Drug Urine Test Panel, Wondfo T-Dip Multi-Drug…Guangzhou Wondfo Biotech Co., Ltd. · 2020
  5. 1 generation backK233062 BioSieveTM Multi-Drug Urine Test Panel; BioSieveTM Multi-Drug Urine…Vivachek Biotech (Hangzhou) Co., Ltd. · 2023
  6. This deviceK261280 BioSieve Multi-Drug Urine Test Panel;BioSieve Multi-Drug Urine Home…Vivachek Biotech (Hangzhou) Co., Ltd. · 2026
Show all 9 generations
  1. Root · 9 generations backK945610 Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM)…Princeton BioMeditech Corp. · 1995
  2. 8 generations backK011673 Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step…ACON Laboratories, Inc. · 2001
  3. 7 generations backK020313 Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step…Acon Laboratories Co. · 2002
  4. 6 generations backK031759 Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon…ACON Laboratories, Inc. · 2003 · Recalled
  5. 5 generations backK061718 Innovacon Spectrum II Test CardInnovacon, Inc. · 2006 · Recalled
  6. 4 generations backK122809 Advin Multi-Drug Screen Test Cassette, Dip Card and CupAdvin Biotech · 2013
  7. 3 generations backK182701 Wondfo T-Cup Multi-Drug Urine Test CupGuangzhou Wondfo Biotech Co., Ltd. · 2018 · Recalled
  8. 2 generations backK202567 Wondfo T-Dip Multi-Drug Urine Test Panel, Wondfo T-Dip Multi-Drug…Guangzhou Wondfo Biotech Co., Ltd. · 2020
  9. 1 generation backK233062 BioSieveTM Multi-Drug Urine Test Panel; BioSieveTM Multi-Drug Urine…Vivachek Biotech (Hangzhou) Co., Ltd. · 2023
  10. This deviceK261280 BioSieve Multi-Drug Urine Test Panel;BioSieve Multi-Drug Urine Home…Vivachek Biotech (Hangzhou) Co., Ltd. · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K945610Abusign (TM) Amp, Doa-Amp, Accusign (TM) Amp-Doa-Amp, Biosign (TM) Amp, Doa-AmpPrinceton BioMeditech Corp.1995—
−8K011673Acon Amp One Step Amphetamine Test Strip, Acon Amp One Step Amphetamine Test…ACON Laboratories, Inc.2001—
−7K020313Acon One Step Multi-Drug Multi-Line Screen Test Card; Acon One Step Multi-Drug…Acon Laboratories Co.2002—
−6K031759Acon Spectrum Multi-Drug Multi-Line Drug Screen Test Card and Acon Spectrum…ACON Laboratories, Inc.20031
−5K061718Innovacon Spectrum II Test CardInnovacon, Inc.20066
−4K122809Advin Multi-Drug Screen Test Cassette, Dip Card and CupAdvin Biotech2013—
−3K182701Wondfo T-Cup Multi-Drug Urine Test CupGuangzhou Wondfo Biotech Co., Ltd.20181
−2K202567Wondfo T-Dip Multi-Drug Urine Test Panel, Wondfo T-Dip Multi-Drug Urine Test…Guangzhou Wondfo Biotech Co., Ltd.2020—
−1K233062BioSieveTM Multi-Drug Urine Test Panel; BioSieveTM Multi-Drug Urine Test Panel…Vivachek Biotech (Hangzhou) Co., Ltd.2023—
0 (this device)K261280BioSieve Multi-Drug Urine Test Panel;BioSieve Multi-Drug Urine Home Test PanelVivachek Biotech (Hangzhou) Co., Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199620
199810
199910
200010
200170
200220
200320
200430
200510
200610
FIG. 1 — Lineage of K261280, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NFT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NFT device

  1. #1 K244043 AllTest Multi-Drug Rapid Test Cup ; AllTest…score 20.3 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K233062BioSieveTM Multi-Drug Urine Test Panel; BioSieveTM Multi-Drug Urine Test Panel Rx
Summary page 7
…NFW 862.3870, Cannabinoids Toxicology Cannabinoids (THC 50) Test System 6. Predicate Device K233062 BioSieve Multi-Drug Urine Test Panel and BioSieve Multi-Drug Urine Test Panel Rx 7. Inte…
Vivachek Biotech (Hangzhou) Co., Ltd.2023—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 31 years and passes through 7 companies; a new generation was cleared every 3.1 years on median.
  • 3 of the 30 ancestors have a recall of any class.

How does its category compare?

All NFT devices

NFT Test, Amphetamine, Over The Counter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · NFT

8in 2025

2017: 12018: 62019: 12020: 22021: 12022: 32023: 12024: 42025: 82026 (partial year): 5
2007high 8 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NFT

37in 2025

2018: 56 days median2022: 63 days median2024: 31 days median2025: 37 days median2026 (partial year): 35 days median
2007high 63 (2022) · low 31 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NFT

No recall names NFT since 2007.

Adverse event reports per year · NFT

No MAUDE report names NFT since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20171—00
201865600
20191—00
20202—00
20211—00
202236300
20231—00
202443100
202583700
20265350—

What is it indicated for?

BioSieveTM Multi-Drug Urine Test Panel tests are competitive binding, lateral flow immunochromatographic assays for qualitative and simultaneous detection of Amphetamine, Buprenorphine, Secobarbital, Oxazepam, Cocaine, 2- ethylidene- 1,5-dimethyl-3,3-diphenylpyrrolidine, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Methadone, Oxycodone, Phencyclidine, Propoxyphene, Nortriptyline, Cannabinoids, Tramadol, Fentanyl, 6-Monoacetylmorphine and…

Read the full statement (524 words)

BioSieveTM Multi-Drug Urine Test Panel tests are competitive binding, lateral flow immunochromatographic assays for

qualitative and simultaneous detection of Amphetamine, Buprenorphine, Secobarbital, Oxazepam, Cocaine, 2- ethylidene-

1,5-dimethyl-3,3-diphenylpyrrolidine, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Methadone,

Oxycodone, Phencyclidine, Propoxyphene, Nortriptyline, Cannabinoids, Tramadol, Fentanyl, 6-Monoacetylmorphine and

Norfentanyl in human urine at the cutoff concentrations of:

Drug Calibrator Cut-off (ng/mL)

Amphetamine (AMP) D-Amphetamine 1,000 or 500

Secobarbital (BAR) Secobarbital 300

Buprenorphine (BUP) Buprenorphine 10

Oxazepam (BZO) Oxazepam 300

Cocaine (COC ) Benzoylecgonine 300 or 150

2-ethylidene-1,5-dimethyl-3,3- 2-ethylidene-1,5-dimethyl-3,3- 300

diphenylpyrrolidine (EDDP) diphenylpyrrolidine

Ecstasy(MDMA) D,L- Methylenedioxy-methamphetamine 500

Methamphetamine (MET) D-Methamphetamine 1,000 or 500

Morphine (MOP/OPI ) Morphine 2,000 or 300

Methadone (MTD) Methadone 300

Oxycodone (OXY ) Oxycodone 100

Phencyclidine (PCP) Phencyclidine 25

Propoxyphene (PPX) Propoxyphene 300

Nortriptyline (TCA) Nortriptyline 1,000

Marjuana (THC ) 11-nor-Δ9-THC-9 COOH 50

Tramadol (TRA) Tramadol 100

Fentanyl (FYL) Fentanyl 1

6-Monoacetylmorphine (6-MAM) 6-Monoacetylmorphine 10

Norfentanyl (NFYL) Norfentanyl 5

The single or multi-test panel can consist of up to nineteen (19) of the above listed analytes in any combination. It is for in

vitro diagnostic use only.

The tests may yield positive results for the prescription drugs Buprenorphine, Nortriptyline, Oxazepam, Secobarbital,

Propoxyphene, and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between

prescription use or abuse of these drugs. Careful consideration and judgment should be applied to any drug of abuse test

result, particularly in evaluating a preliminary positive result.

The tests provide only preliminary results. To obtain a confirmed analytical result, a more specific alternate chemical

method must be used. GC/MS or LC/MS is the recommended confirmatory method.

BioSieveTM Multi-Drug Urine Home Test Panel is competitive binding, lateral flow immunochromatographic assay for

qualitative and simultaneous detection of Amphetamine, Buprenorphine, Secobarbital, Oxazepam, Cocaine, 2-ethylidene-

1,5-dimethyl-3,3-diphenylpyrrolidine, Methamphetamine, Methylenedioxymethamphetamine, Morphine, Methadone,

Oxycodone, Phencyclidine, Propoxyphene, Nortriptyline, Marijuana, Tramadol, Fentanyl, 6-Monoacetylmorphine and

Norfentanyl in human urine at the cutoff concentrations of:

Drug (Identifier) Cut-off level

Amphetamine (AMP) 500 ng/mL or 1000 ng/mL

Buprenorphine (BUP) 10 ng/mL

Secobarbital (BAR) 300 ng/mL

Oxazepam (BZO) 300 ng/mL

Cocaine (COC) 150 ng/mL or 300 ng/mL

2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) 300 ng/mL

Methamphetamine (MET) 500 ng/mL or 1000 ng/mL

Methylenedioxymethamphetamine (MDMA) 500 ng/mL

Morphine (MOP 300/OPI 2000) 300 ng/mL or 2000 ng/mL

Methadone (MTD) 300 ng/mL

Oxycodone (OXY) 100 ng/mL

Phencyclidine (PCP) 25 ng/mL

Propoxyphene (PPX) 300 ng/mL

Nortriptyline (TCA) 1000 ng/mL

Marijuana (THC) 50 ng/mL

Tramadol (TRA) 100 ng/mL

Fentanyl (FYL) 1 ng/mL

6-Monoacetylmorphine (6-MAM) 10 ng/mL

Norfentanyl (NFYL) 5 ng/mL

The single or multi-test panel can consist of up to nineteen (19) of the above listed analytes in any combination. It is for in

vitro diagnostic use only. It is intended for OTC use.

The test may yield positive results for the prescription drugs Buprenorphine, Oxazepam, Secobarbital, Nortriptyline,

Propoxyphene and Oxycodone when taken at or above prescribed doses. It is not intended to distinguish between

prescription use or abuse of these drugs. Careful consideration and judgment should be applied to any drug of abuse test

result, particularly in evaluating a preliminary positive result.

The tests provide only preliminary results. To obtain a confirmed analytical result, a more specific alternative chemical

method must be used. GC/MS or LC/MS is the recommended confirmatory method.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K261280: BioSieve Multi-Drug Urine Test Panel;BioSieve Multi-Drug Urine Home Test Panel.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K261280

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026