510(k) Report

510(k) · Cleared

Cleared

3M™ Attest™ Steam Chemical Integrator (1243A, 1243B, 1243RE, 1243RES)

K261992510(k) TraditionalCleared Sep 25, 2026102-day reviewClass II21 CFR 880.2800

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Solventum US, LLC · JOJ Indicator, Physical/Chemical Sterilization Process

Cleared on Sep 25, 2026 as substantially equivalent to K220942 (3M Company, 2022) after a 102-day review. Its family tree reaches back 5 generations to 1977.

Decided
Sep 25, 2026
Review
102 days
Class
Class II
Product code
JOJ
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K771080 (1977). No later device cites it as a predicate yet.

  1. Root · 5 generations backK771080 Steam Sterilization IndicatorInfo-Chem · 1977
  2. 4 generations backK101249 Sterigage Model 1243RA, 1243RB, 1243RE3M Company · 2010
  3. 3 generations backK191236 3M™ Attest™ Steam Chemical Integrators3M Company · 2019
  4. 2 generations backK193254 3M Attest Steam Chemical Integrator3M Company · 2019
  5. 1 generation backK220942 3M Attest Steam Chemical Integrators (1243A, 1243B, 1243RE, 1243RES)3M Company · 2022 · Recalled
  6. This deviceK261992 3M™ Attest™ Steam Chemical Integrator (1243A, 1243B, 1243RE, 1243RES)Solventum US, LLC · 2026
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K771080Steam Sterilization IndicatorInfo-Chem1977—
−4K101249Sterigage Model 1243RA, 1243RB, 1243RE3M Company2010—
−3K1912363M™ Attest™ Steam Chemical Integrators3M Company2019—
−2K1932543M Attest Steam Chemical Integrator3M Company2019—
−1K2209423M Attest Steam Chemical Integrators (1243A, 1243B, 1243RE, 1243RES)3M Company20222
0 (this device)K2619923M™ Attest™ Steam Chemical Integrator (1243A, 1243B, 1243RE, 1243RES)Solventum US, LLC2026—
FIG. 1 — Lineage of K261992, 1977–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JOJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JOJ device

  1. #1 K240760 CELERITY HP Indicator Tapescore 12.6 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K2209423M Attest Steam Chemical Integrators (1243A, 1243B, 1243RE, 1243RES)
Summary page 7
…al/chemical sterilization process indicator Class II, Device Classification: 21 CFR § 880.2800(b) Product Code: JOJ 2. Predicate Device: K220942, 3M™ Attest™ Steam Chemical Integrator 3. Description of Device: 3M™ Attest™ Steam Chemical Integrators are chemical indicat…
3M Company20222

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 49 years and passes through 3 companies; a new generation was cleared every 4.3 years on median.
  • 1 of the 5 ancestors has a recall of any class.

How does its category compare?

All JOJ devices

JOJ Indicator, Physical/Chemical Sterilization Process: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.

FDA decisions per year · JOJ

6in 2025

2007: 82008: 92009: 72010: 62011: 132012: 72013: 62014: 62015: 82016: 42017: 72018: 52019: 122020: 72021: 42022: 82023: 42024: 122025: 62026 (partial year): 3
2007high 13 (2011) · low 4 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JOJ

90in 2025

2007: 140 days median2008: 57 days median2009: 188 days median2010: 115 days median2011: 151 days median2012: 224 days median2013: 212 days median2014: 198 days median2015: 188 days median2016: 150 days median2017: 172 days median2018: 150 days median2019: 38 days median2020: 108 days median2021: 87 days median2022: 90 days median2023: 53 days median2024: 71 days median2025: 90 days median2026 (partial year): 30 days median
2007high 224 (2012) · low 38 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JOJ

1in 2023

2008: 22009: 22011: 22021: 12023: 1
2007high 2 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JOJ

12in 2025

2007: 12008: 12009: 92010: 32011: 12012: 82013: 62014: 112015: 72016: 112017: 352018: 122019: 82020: 62021: 292022: 232023: 392024: 252025: 12
2007high 39 (2023) · low 1 (2007)2025

MAUDE reports naming product code JOJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007814001
200895721
2009718829
2010611503
20111315121
2012722408
2013621206
20146198011
2015818807
20164150011
20177172035
20185150012
2019123808
2020710806
2021487129
2022890023
2023453139
20241271025
2025690012
20263300—

What is it indicated for?

The 3M™ Attest™ Steam Chemical Integrators are designed to respond to all critical parameters over a specified range of steam sterilization cycles. The integrating indicator is intended to be placed in each pack, pouch, container, tray or other critical containment device to function as an independent monitor of critical parameters for the following sterilization cycles: Cycle Type Temperature Exposure Time Gravity 250°F/121°C 30 minutes Gravity…

Read the full statement (184 words)

The 3M™ Attest™ Steam Chemical Integrators are designed to respond to all critical parameters over a specified range of

steam sterilization cycles. The integrating indicator is intended to be placed in each pack, pouch, container, tray or other

critical containment device to function as an independent monitor of critical parameters for the following sterilization

cycles:

Cycle Type Temperature Exposure Time

Gravity 250°F/121°C 30 minutes

Gravity 270°F/132°C 3 minutes

Gravity 270°F/132°C 4 minutes

Gravity 270°F/132°C 10 minutes

Gravity 270°F/132°C 15 minutes

Gravity 270°F/132°C 25 minutes

Gravity 275°F/135°C 3 minutes

Gravity 275°F/135°C 10 minutes

Dynamic Air Removal 250°F/121°C 30 minutes

Dynamic Air Removal 270°F/132°C 4 minutes

Dynamic Air Removal 270°F/132°C 5 minutes

Dynamic Air Removal 270°F/132°C 6 minutes

Dynamic Air Removal 270°F/132°C 7 minutes

Dynamic Air Removal 270°F/132°C 8 minutes

Dynamic Air Removal 270°F/132°C 9 minutes

Dynamic Air Removal 270°F/132°C 10 minutes

Dynamic Air Removal 273°F/134°C 3 minutes

Dynamic Air Removal 273°F/134°C 4 minutes

Dynamic Air Removal 275°F/135°C 3 minutes

Minimum Stated Values for 3M™ Attest™ Steam Chemical Integrators as determined in a resistometer:

250°F/121°C 270°F/132°C 273°F/134°C

16.5 Minutes 2.0 Minutes 1.4 Minutes

275°F/135°C

1.2 Minutes

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K261992: 3M™ Attest™ Steam Chemical Integrator (1243A, 1243B, 1243RE, 1243RES).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K261992

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded Oct 30, 2026
  • Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026