Table, X-Ray, RFX Classical

K760466510(k) TraditionalCleared Aug 26, 19768-day reviewClass II21 CFR 892.1980Recalls 8

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

General Electric Co. · IXR Table, Radiographic, Tilting

Cleared on Aug 26, 1976 after an 8-day review. FDA has not posted a summary or statement for it, so its predicates are not known. It has been recalled 8 times.

Decided
Aug 26, 1976
Review
8 days
Class
Class II
Product code
IXR
Recalls
8
Predicates
0

FDA has not posted a summary or statement for it, so its predicates are not known.

FIG. 1 — Lineage of K760466Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IXR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA has not posted a summary or statement for it, so its predicates are not known.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 6, 2017Class IIZ-2179-2017Device DesignReported incidents of a patient step detaching from the table. A fall from a patient step detaching while in use could result in an injury to a patient or operator.
Nov 21, 2016Class IIZ-0915-2017Nonconforming Material/ComponentGE Healthcare is conducting a recall due to the potential fall of aged CRT monitors - Prestige 2, Prestilix, Prestige VH, Prestige SI, RFX/SFX, Legacy, Precision 500D, ADVANTX and Innova 2000 systems.
Aug 30, 2013Class IIZ-0012-2014Employee errorGE Healthcare has recently become aware of a potential safety issue involving the spotfilm device power assist handle. There is a potential for the internal bolts on the power assist handle to be loose or to loosen and/or fall out. This…
Mar 9, 2007Not classifiedZ-0200-2009Component change controlGE Healthcare has recently become aware of a potential risk of monitor dropping associated with the monitor suspension of the Advantx system that may impact patient safety. It has been reported that suspensions manufactured after March 8…
Mar 30, 2004Not classifiedZ-0852-04OtherThe ball joint that attaches the single monitor platform to the system boom could fail causing the monitor to fall.
Mar 30, 2004Not classifiedZ-0851-04OtherThe ball joint that attaches the single monitor platform to the system boom could fail causing the monitor to fall.
Mar 30, 2004Not classifiedZ-0850-04OtherThe ball joint that attaches the single monitor platform to the system boom could fail causing the monitor to fall.
Mar 30, 2004Not classifiedZ-0853-04OtherThe ball joint that attaches the single monitor platform to the system boom could fail causing the monitor to fall.

No ancestor or descendant has a Class I recall.

How does its category compare?

All IXR devices

IXR Table, Radiographic, Tilting: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · IXR

FDA has decided no IXR device since 2007.

Median 510(k) review, days · IXR

Too few IXR 510(k)s in any year since 2007 to give a median.

Recalls per year · IXR

1in 2025

2007: 12008: 42010: 52016: 12017: 12019: 12025: 1
2007high 5 (2010) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · IXR

1in 2024

2007: 42008: 82009: 12010: 122011: 102012: 1642013: 1962014: 1202015: 822016: 582017: 252018: 172019: 82020: 122021: 52022: 22023: 12024: 1
2007high 196 (2013) · low 0 (2025)2025

MAUDE reports naming product code IXR, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—14
20080—48
20090—01
20100—512
20110—010
20120—0164
20130—0196
20140—0120
20150—082
20160—158
20170—125
20180—017
20190—18
20200—012
20210—05
20220—02
20230—01
20240—01
20250—10
20260—0—
Cite this page

510(k) Report. “K760466: Table, X-Ray, RFX Classical.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K760466

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Page last updated Nov 3, 2026