Models MR410 & MR480 Respiratory Humidifier/Access

K913367510(k) TraditionalCleared Jun 25, 1992337-day reviewClass II21 CFR 868.5450

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fisher & Paykel Electronics, Ltd. · BTT Humidifier, Respiratory Gas, (Direct Patient Interface)

Cleared on Jun 25, 1992 after a 337-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 4 of the 76 devices in its family, counting itself, have a Class I recall. 75 later devices descend from it.

Decided
Jun 25, 1992
Review
337 days
Class
Class II
Product code
BTT
Recalls
None
Predicates
0

75 later devices descend from it, 1 citing it directly. 4 of the 76 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 1996: 1 descendant cleared1998: 1 descendant cleared2013: 4 descendants cleared2014: 5 descendants cleared, 1 with a Class I recall12015: 2 descendants cleared2003: 1 descendant cleared2016: 4 descendants cleared, 1 with a Class I recall12017: 3 descendants cleared, 1 with a Class I recall12023: 7 descendants cleared2011: 2 descendants cleared2010: 4 descendants cleared2000: 2 descendants cleared2004: 1 descendant cleared2005: 1 descendant cleared2006: 1 descendant cleared2008: 1 descendant cleared2007: 2 descendants cleared2012: 3 descendants cleared2024: 9 descendants cleared2021: 3 descendants cleared2025: 6 descendants cleared2022: 3 descendants cleared2018: 3 descendants cleared, 1 with a Class I recall12026: 4 descendants cleared2019: 1 descendant cleared2020: 1 descendant cleared1990200020102020
  1. This deviceK913367 Models MR410 & MR480 Respiratory Humidifier/AccessFisher & Paykel Electronics, Ltd. · 1992
  2. Descendant · cites it directly · 74 of its ownK953392 HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd. · 1996
  3. Descendant · 2 generations on · 73 of its ownK983112 Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd. · 1998 · Recalled
  4. Descendant · 3 generations on · 65 of its ownK020332 Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2003 · Recalled
  5. Descendant · 4 generations on · 54 of its ownK033710 MR850 Respiratory Humidifier, Model MR850JHUFisher & Paykel Healthcare, Ltd. · 2004
  6. Descendant · 5 generations on · 47 of its ownK073706 Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2008

Showing 5 of 75 descendants. See all descendants

Descendants cleared per year

1996: 11998: 12000: 22003: 12004: 12005: 12006: 12007: 22008: 12010: 42011: 22012: 32013: 42014: 52015: 22016: 42017: 32018: 32019: 12020: 12021: 32022: 32023: 72024: 92025: 62026: 4
1996high 9 (2024) · low 0 (1997)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 75 · See all
  • K953392HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd. · 1996 · cites it directly74descendants
  • K983112Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd. · 1998 · 2 generations on73descendants
  • K020332Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2003 · 3 generations on65descendants
  • K033710MR850 Respiratory Humidifier, Model MR850JHUFisher & Paykel Healthcare, Ltd. · 2004 · 4 generations on54descendants
  • K073706Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd. · 2008 · 5 generations on47descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K913367Models MR410 & MR480 Respiratory Humidifier/AccessFisher & Paykel Electronics, Ltd.1992—
+1K953392HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd.1996—
+2K983112Respiratory Humidifier, Model # MR850Fisher & Paykel Healthcare, Ltd.19985
+3K020332Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd.20031
+4K033710MR850 Respiratory Humidifier, Model MR850JHUFisher & Paykel Healthcare, Ltd.2004—
+5K073706Respiratory Humidifier, Model MR850Fisher & Paykel Healthcare, Ltd.2008—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199610
199810
200020
200310
200410
200510
200610
200720
200810
201040
201120
201230
201340
201451
201520
201641
201731
201831
201910
202010
202130
202230
202370
202490
202560
202640
FIG. 1 — Lineage of K913367, 1992–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

4 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTT device

  1. #1 K222197 F&P Optiflow Junior 2/2+ Nasal Cannula…score 16.8 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (75)

See all 75

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K953392HC500 Servo-Controlled Heated Respiratory Humidifier (& Accessories)Fisher & Paykel Electronics, Ltd.199674

Has anything in its family been recalled? (4 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K151303AirLife Infant Heated Wire CircuitCare Fusion · 2016 · 4 generations on · ◆ in the 2016 descendants bar of FIG. 12 Class I recalls
  • K131912Conchatherm Neptune Heated Humidifier, Comfort Flo Humidification System, Conchasmart ColumnTeleflex, Inc. · 2014 · 6 generations on · ◆ in the 2014 descendants bar of FIG. 12 Class I recalls
  • K173280Neonatal ConchaSmart Breathing CircuitsTeleflexmedical, Inc. · 2018 · 6 generations on · ◆ in the 2018 descendants bar of FIG. 11 Class I recall
  • K162242Comfort Flo Humidification SystemTeleflexmedical, Inc. · 2017 · 7 generations on · ◆ in the 2017 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Of its descendants, K953392 (Fisher & Paykel Electronics, Ltd., 1996) has gone furthest, with 74 descendants of its own.

How does its category compare?

All BTT devices

BTT Humidifier, Respiratory Gas, (Direct Patient Interface): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · BTT

4in 2025

2007: 62008: 42009: 12010: 42011: 32012: 22013: 62014: 72015: 12016: 32017: 32018: 22019: 12020: 22021: 22022: 32023: 72024: 72025: 42026 (partial year): 4
2007high 7 (2014) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTT

104in 2025

2007: 73 days median2008: 199 days median2010: 113 days median2011: 116 days median2013: 171 days median2014: 231 days median2016: 157 days median2017: 303 days median2022: 290 days median2023: 258 days median2024: 219 days median2025: 104 days median2026 (partial year): 184 days median
2007high 303 (2017) · low 73 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTT

1in 2025

2007: 12008: 12010: 22011: 12014: 5, 4 Class I2025: 12026 (partial year): 1
2007high 5 (2014) · low 0 (2009)2026

Class I (4 since 2007) Class II/III not classified

Adverse event reports per year · BTT

1,743in 2025

2007: 3652008: 4562009: 5582010: 5622011: 6652012: 5832013: 7182014: 7182015: 6702016: 1,0942017: 1,0072018: 9182019: 8942020: 1,1882021: 1,5102022: 7492023: 7162024: 5012025: 1,743
2007high 1,743 (2025) · low 365 (2007)2025

MAUDE reports naming product code BTT, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20076731365
200841991456
20091—0558
201041132562
201131161665
20122—0583
201361710718
201472315 (4)718
20151—0670
2016315701,094
2017330301,007
20182—0918
20191—0894
20202—01,188
20212—01,510
202232900749
202372580716
202472190501
2025410411,743
202641841—
Cite this page

510(k) Report. “K913367: Models MR410 & MR480 Respiratory Humidifier/Access.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K913367

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026