510(k) · Cleared
ClearedProvident HP System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Stelkast Company · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Cleared on Apr 5, 1995 after a 120-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 32 later devices descend from it.
- Decided
- Apr 5, 1995
- Review
- 120 days
- Class
- Class II
- Product code
- JDI
- Recalls
- None
- Predicates
- 0
32 later devices descend from it, 2 citing it directly.
- This deviceK946371 Provident HP SystemStelkast Company · 1995
- Descendant · cites it directly · 28 of its ownK073068 Accin Hip SystemAccelerated Innovation, LLC · 2008
- Descendant · 2 generations on · 25 of its ownK100445 Klassic HD Hip SystemTotal Joint Orthopedics, Inc. · 2010
- Descendant · 3 generations on · 16 of its ownK143407 Klassic HD Hip SystemTotal Joint Othopedics, Inc. · 2014
- Descendant · 3 generations on · 14 of its ownK141972 Klassic HD Acetabular Insert with E-Link PolyTotal Joint Orthopedics, Inc. · 2014
- Descendant · 4 generations on · 9 of its ownK163577 Ecofit® Hip SystemImplantcast GmbH · 2017 · Recalled
Showing 5 of 32 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 32 · See all- K073068Accin Hip SystemAccelerated Innovation, LLC · 2008 · cites it directly28descendants
- K100445Klassic HD Hip SystemTotal Joint Orthopedics, Inc. · 2010 · 2 generations on25descendants
- K143407Klassic HD Hip SystemTotal Joint Othopedics, Inc. · 2014 · 3 generations on16descendants
- K141972Klassic HD Acetabular Insert with E-Link PolyTotal Joint Orthopedics, Inc. · 2014 · 3 generations on14descendants
- K163577Ecofit® Hip SystemImplantcast GmbH · 2017 · 4 generations on9descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K946371 | Provident HP System | Stelkast Company | 1995 | — |
| +1 | K073068 | Accin Hip System | Accelerated Innovation, LLC | 2008 | — |
| +2 | K100445 | Klassic HD Hip System | Total Joint Orthopedics, Inc. | 2010 | — |
| +3 | K143407 | Klassic HD Hip System | Total Joint Othopedics, Inc. | 2014 | — |
| +3 | K141972 | Klassic HD Acetabular Insert with E-Link Poly | Total Joint Orthopedics, Inc. | 2014 | — |
| +4 | K163577 | Ecofit® Hip System | Implantcast GmbH | 2017 | 1 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2008 | 1 | 0 |
| 2010 | 3 | 0 |
| 2014 | 4 | 0 |
| 2015 | 2 | 0 |
| 2016 | 1 | 0 |
| 2017 | 3 | 0 |
| 2018 | 2 | 0 |
| 2019 | 2 | 0 |
| 2021 | 3 | 0 |
| 2022 | 3 | 0 |
| 2023 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
| 2026 | 4 | 0 |
Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDI device
- #1 K253515 Zimmer Biomet OSS™ Orthopedic Salvage System…score 15.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.
What descends from it? (32)
See all 322 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K073068 (Accelerated Innovation, LLC, 2008) has gone furthest, with 28 descendants of its own.
How does its category compare?
All JDI devicesJDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDI
59in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDI
1,644in 2025
MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 26 | 696 |
| 2008 | 5 | 96 | 6 | 810 |
| 2009 | 3 | 65 | 3 | 964 |
| 2010 | 0 | — | 3 | 2,040 |
| 2011 | 2 | — | 5 | 3,160 |
| 2012 | 4 | 167 | 4 | 5,122 |
| 2013 | 3 | 176 | 11 | 5,206 |
| 2014 | 3 | 98 | 3 | 4,968 |
| 2015 | 3 | 190 | 1 | 4,906 |
| 2016 | 4 | 166 | 5 | 3,995 |
| 2017 | 1 | — | 5 | 6,135 |
| 2018 | 1 | — | 1 | 6,728 |
| 2019 | 2 | — | 1 | 7,407 |
| 2020 | 7 | 247 | 77 | 4,015 |
| 2021 | 3 | 162 | 0 | 3,170 |
| 2022 | 3 | 69 | 0 | 1,978 |
| 2023 | 2 | — | 0 | 1,635 |
| 2024 | 3 | 59 | 0 | 1,821 |
| 2025 | 1 | — | 1 | 1,644 |
| 2026 | 2 | — | 0 | — |
https://510kreport.com/device/K946371 · printed Nov 4, 2026
Cite this page
510(k) Report. “K946371: Provident HP System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K946371
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026