510(k) · Cleared
Recalled · 2011Advantage Windows with Functool Option
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
GE Medical Systems · LLZ System, Image Processing, Radiological
Cleared on Jul 3, 1996 as substantially equivalent to K913770 (General Electric Co., 1991) and 1 other predicate after a 167-day review. Its family tree reaches back 1 generation to 1991. 2 of the 183 devices in its family, counting itself, have a Class I recall. 180 later devices descend from it. It has been recalled once.
- Decided
- Jul 3, 1996
- Review
- 167 days
- Class
- Class II
- Product code
- LLZ
- Recalls
- 1
- Predicates
- 2
Its longest line of descent runs back 1 generation to K913475 (1991). 2 ancestors in all. 180 later devices descend from it, 13 citing it directly. 2 of the 183 devices in this family, counting this one, have a Class I recall.
- Root · 1 generation backK913475 Magnetic Resonance Diagnostic DeviceGE Medical Systems · 1991
- This deviceK960265 Advantage Windows with Functool OptionGE Medical Systems · 1996
- Descendant · cites it directly · 74 of its ownK971965 Philips EasyvisionPhilips Medical Systems, Inc. · 1998
- Descendant · 2 generations on · 48 of its ownK022292 Impax Diagnostic Display Station,Impax Clinical Review Station,Impax…Agfa Corp. · 2002 · Recalled
- Descendant · cites it directly · 38 of its ownK110573 Ready ViewGe Healthcare (Ge Medical Systems Scs) · 2011 · Recalled
- Descendant · cites it directly · 32 of its ownK061429 Dynamic Mri Software Option for C-Scan, E-Scan XQ and E-Scan OperaEsaote, S.p.A. · 2006
- Descendant · cites it directly · 27 of its ownK063505 Visualase Envision Software SystemBiotex, Inc. · 2006
Showing 5 of 180 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 180 · See all- K971965Philips EasyvisionPhilips Medical Systems, Inc. · 1998 · cites it directly74descendants
- K022292Impax Diagnostic Display Station,Impax Clinical Review Station,Impax for Cardiology…Agfa Corp. · 2002 · 2 generations on48descendants
- K110573Ready ViewGe Healthcare (Ge Medical Systems Scs) · 2011 · cites it directly38descendants
- K061429Dynamic Mri Software Option for C-Scan, E-Scan XQ and E-Scan OperaEsaote, S.p.A. · 2006 · cites it directly32descendants
- K063505Visualase Envision Software SystemBiotex, Inc. · 2006 · cites it directly27descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K913475 | Magnetic Resonance Diagnostic Device | GE Medical Systems | 1991 | — |
| 0 (this device) | K960265 | Advantage Windows with Functool Option | GE Medical Systems | 1996 | — |
| +1 | K971965 | Philips Easyvision | Philips Medical Systems, Inc. | 1998 | — |
| +2 | K022292 | Impax Diagnostic Display Station,Impax Clinical Review Station,Impax for… | Agfa Corp. | 2002 | 9 |
| +1 | K110573 | Ready View | Ge Healthcare (Ge Medical Systems Scs) | 2011 | 1 |
| +1 | K061429 | Dynamic Mri Software Option for C-Scan, E-Scan XQ and E-Scan Opera | Esaote, S.p.A. | 2006 | — |
| +1 | K063505 | Visualase Envision Software System | Biotex, Inc. | 2006 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1991 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 2 | 0 |
| 1999 | 1 | 0 |
| 2002 | 1 | 0 |
| 2003 | 5 | 0 |
| 2004 | 5 | 0 |
| 2005 | 7 | 0 |
| 2006 | 5 | 0 |
| 2007 | 2 | 0 |
| 2008 | 6 | 0 |
| 2009 | 8 | 0 |
| 2010 | 2 | 0 |
| 2011 | 7 | 0 |
| 2012 | 13 | 0 |
| 2013 | 9 | 0 |
| 2014 | 5 | 0 |
| 2015 | 9 | 1 |
| 2016 | 8 | 0 |
| 2017 | 9 | 1 |
| 2018 | 10 | 0 |
| 2019 | 5 | 0 |
| 2020 | 8 | 0 |
| 2021 | 7 | 0 |
| 2022 | 6 | 0 |
| 2023 | 6 | 0 |
| 2024 | 12 | 0 |
| 2025 | 9 | 0 |
| 2026 | 13 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LLZ device
- #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K913770 | Advantage V.S. CT/MR Rad Diagnostic WorkstationSummary page 1…previously marketed devices. Conclusions It is the opinion of GE that the FuncTool Option is substantially equivalent to the Advantage Windows Diagnostic Workstation (K913770) and Signa Advantage (K913475) . The FuncTool Option does not include any new indications for use, nor does use of this device re… | 1991 |
| * | K913475 | Magnetic Resonance Diagnostic DeviceSummary page 1…GE's CT and MR Systems. Marketing History This software is presently being marketed as the Multiple Region of Interest (MIROI) function in the Signa MR Systems 510(k) K913475. FuncTool automates what is presently done manually. Comparison with Predicate The use of the FuncTool Option does not result i… | 1991 |
What descends from it? (180)
See all 18013 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K971965 | Philips Easyvision | 1998 | 74 |
| K110573 | Ready View | 2011 | 38 |
| K061429 | Dynamic Mri Software Option for C-Scan, E-Scan XQ and E-Scan Opera | 2006 | 32 |
| K063505 | Visualase Envision Software System | 2006 | 27 |
| K031350 | 3TP Software Option | 2003 | 19 |
| K041286 | Dynacad V1.0 | 2004 | 17 |
| K043350 | Mistar, Model V3.2 | 2004 | 12 |
| K052963 | Mediq Version 1.0 | 2005 | 11 |
| K050862 | 3TP Workspace | 2005 | 10 |
| K081556 | Cadstream, Version 5.0 | 2009 | 9 |
Has anything in its family been recalled? (2 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Aug 18, 2011 | Not classified | Z-3282-2011 | Software design | GE Healthcare has become aware that image orientation of reference series displayed in Functool Diffusion Tensor/FiberTrak protocol on Advantage Workstation may not match with the orientation annotations displayed in the viewport. This… |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
What does this lineage say?
How does its category compare?
All LLZ devicesLLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · LLZ
58in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LLZ
173in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LLZ
11in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LLZ
116in 2025
MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 76 | 36 | 20 | 152 |
| 2008 | 94 | 52 | 32 | 154 |
| 2009 | 70 | 62 | 21 | 145 |
| 2010 | 51 | 98 | 17 | 145 |
| 2011 | 106 | 79 | 30 | 454 |
| 2012 | 82 | 87 | 12 | 266 |
| 2013 | 95 | 84 | 64 | 1,130 |
| 2014 | 78 | 89 | 6 | 15,631 |
| 2015 | 64 | 90 | 16 | 211 |
| 2016 | 82 | 90 | 12 | 290 |
| 2017 | 78 | 107 | 5 | 104 |
| 2018 | 104 | 105 | 7 | 72 |
| 2019 | 74 | 107 | 2 | 88 |
| 2020 | 81 | 115 | 6 | 82 |
| 2021 | 83 | 116 | 3 | 70 |
| 2022 | 65 | 137 | 4 | 28 |
| 2023 | 87 | 157 | 8 | 26 |
| 2024 | 62 | 131 | 6 | 42 |
| 2025 | 58 | 173 | 11 | 116 |
| 2026 | 45 | 110 | 14 | — |
What is it indicated for?
The FuncTool option to the Advantages Windows workstation is a software module that provides supplemental information to those images extracted from CT and MR temporal datasets.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K960265 · printed Nov 6, 2026
Cite this page
510(k) Report. “K960265: Advantage Windows with Functool Option.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960265
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026