Pulmo CT with Reference Database for the Somatom Plus and Plus 4 Computed Tomography Systems

K960635510(k) TraditionalCleared Apr 3, 199649-day reviewClass II21 CFR 892.1750

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Medical Solutions USA, Inc. · JAK System, X-Ray, Tomography, Computed

Cleared on Apr 3, 1996 after a 49-day review. The FDA summary names its predicate without a number. 1 of the 212 devices in its family, counting itself, has a Class I recall. 211 later devices descend from it.

Decided
Apr 3, 1996
Review
49 days
Class
Class II
Product code
JAK
Recalls
None
Predicates
0

211 later devices descend from it, 1 citing it directly. 1 of the 212 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2007: 1 descendant cleared2008: 2 descendants cleared2013: 5 descendants cleared2012: 8 descendants cleared2011: 3 descendants cleared2010: 2 descendants cleared2009: 1 descendant cleared2018: 13 descendants cleared2020: 22 descendants cleared2015: 11 descendants cleared2014: 7 descendants cleared2022: 20 descendants cleared2019: 13 descendants cleared2016: 8 descendants cleared2023: 18 descendants cleared2024: 20 descendants cleared2021: 9 descendants cleared2017: 7 descendants cleared2025: 24 descendants cleared, 1 with a Class I recall12026: 17 descendants cleared1995200020052010201520202025
  1. This deviceK960635 Pulmo CT with Reference Database for the Somatom Plus and Plus 4…Siemens Medical Solutions USA, Inc. · 1996
  2. Descendant · cites it directly · 210 of its ownK071513 Inspace 4D Software Package with Extended FunctionalitySiemens Medical Solutions · 2007
  3. Descendant · 2 generations on · 168 of its ownK073003 Syngo Dual Energy with Extended FunctionallySiemens Medi Cal Solutions, Inc. · 2008
  4. Descendant · 3 generations on · 117 of its ownK083524 Syngo Dual Energy with Extended FunationallySiemens Medical Solutions USA, Inc. · 2009
  5. Descendant · 4 generations on · 99 of its ownK112020 Syngo.CT Vascular AnalysisSiemens Medi Cal Solutions, Inc. · 2011
  6. Descendant · 5 generations on · 63 of its ownK123920 Syngo.ViaSiemens AG Medical Solutions · 2013

Showing 5 of 211 descendants. See all descendants

Descendants cleared per year

2007: 12008: 22009: 12010: 22011: 32012: 82013: 52014: 72015: 112016: 82017: 72018: 132019: 132020: 222021: 92022: 202023: 182024: 202025: 242026: 17
2007high 24 (2025) · low 1 (2007)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 211 · See all
  • K071513Inspace 4D Software Package with Extended FunctionalitySiemens Medical Solutions · 2007 · cites it directly210descendants
  • K073003Syngo Dual Energy with Extended FunctionallySiemens Medi Cal Solutions, Inc. · 2008 · 2 generations on168descendants
  • K083524Syngo Dual Energy with Extended FunationallySiemens Medical Solutions USA, Inc. · 2009 · 3 generations on117descendants
  • K112020Syngo.CT Vascular AnalysisSiemens Medi Cal Solutions, Inc. · 2011 · 4 generations on99descendants
  • K123920Syngo.ViaSiemens AG Medical Solutions · 2013 · 5 generations on63descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K960635Pulmo CT with Reference Database for the Somatom Plus and Plus 4 Computed…Siemens Medical Solutions USA, Inc.1996—
+1K071513Inspace 4D Software Package with Extended FunctionalitySiemens Medical Solutions2007—
+2K073003Syngo Dual Energy with Extended FunctionallySiemens Medi Cal Solutions, Inc.2008—
+3K083524Syngo Dual Energy with Extended FunationallySiemens Medical Solutions USA, Inc.2009—
+4K112020Syngo.CT Vascular AnalysisSiemens Medi Cal Solutions, Inc.2011—
+5K123920Syngo.ViaSiemens AG Medical Solutions2013—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200710
200820
200910
201020
201130
201280
201350
201470
2015110
201680
201770
2018130
2019130
2020220
202190
2022200
2023180
2024200
2025241
2026170
FIG. 1 — Lineage of K960635, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAK device

  1. #1 K230223 iCAC Devicescore 23.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Pulmo CT option in SOMATOM Plus CT
Named without a submission number
—
*—Pulmo CT option in SOMATOM Plus 4 CT
Named without a submission number
—

What descends from it? (211)

See all 211

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K071513Inspace 4D Software Package with Extended FunctionalitySiemens Medical Solutions2007210

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K250443MAGNETOM Avanto Fit; MAGNETOM Skyra Fit; MAGNETOM Sola Fit; MAGNETOM Viato.MobileSiemens Healthcare GmbH · 2025 · 8 generations on · ◆ in the 2025 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Of its descendants, K071513 (Siemens Medical Solutions, 2007) has gone furthest, with 210 descendants of its own.

How does its category compare?

All JAK devices

JAK System, X-Ray, Tomography, Computed: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JAK

27in 2025

2007: 142008: 262009: 152010: 72011: 162012: 282013: 172014: 302015: 302016: 252017: 292018: 242019: 282020: 302021: 202022: 302023: 272024: 262025: 272026 (partial year): 21
2007high 30 (2014) · low 7 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAK

141in 2025

2007: 27 days median2008: 42 days median2009: 31 days median2010: 92 days median2011: 155 days median2012: 121 days median2013: 132 days median2014: 200 days median2015: 140 days median2016: 129 days median2017: 96 days median2018: 114 days median2019: 94 days median2020: 112 days median2021: 145 days median2022: 131 days median2023: 139 days median2024: 141 days median2025: 141 days median2026 (partial year): 167 days median
2007high 200 (2014) · low 27 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAK

17in 2025

2007: 112008: 162009: 292010: 512011: 342012: 232013: 112014: 102015: 282016: 442017: 332018: 102019: 52020: 82021: 152022: 92023: 92024: 202025: 172026 (partial year): 23
2007high 51 (2010) · low 5 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAK

219in 2025

2007: 762008: 1202009: 1052010: 1192011: 2052012: 1922013: 4142014: 3082015: 4542016: 3652017: 3382018: 5432019: 2332020: 1772021: 2612022: 1992023: 3102024: 2122025: 219
2007high 543 (2018) · low 76 (2007)2025

MAUDE reports naming product code JAK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714271176
2008264216120
2009153129105
201079251119
20111615534205
20122812123192
20131713211414
20143020010308
20153014028454
20162512944365
2017299633338
20182411410543
201928945233
2020301128177
20212014515261
2022301319199
2023271399310
20242614120212
20252714117219
20262116723—

What is it indicated for?

The Pulmo CT with Reference Database is intended for diagnostic imaging. It provides highly reproducible CT values for pulmonary tissue, which is essential for follow up examinations and for providing quantitative support for diagnosis.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K960635: Pulmo CT with Reference Database for the Somatom Plus and Plus 4 Computed Tomography Systems.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K960635

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026