510(k) Report

510(k) · Cleared

Cleared

Novus Standard and Pediatric Valves

K961859510(k) TraditionalCleared Dec 16, 1996216-day reviewClass II21 CFR 882.5550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Neurocare, LLC · JXG Shunt, Central Nervous System And Components

Cleared on Dec 16, 1996 after a 216-day review. FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known. 5 later devices descend from it.

Decided
Dec 16, 1996
Review
216 days
Class
Class II
Product code
JXG
Recalls
None
Predicates
0

5 later devices descend from it, 3 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2002: 1 descendant cleared1998: 1 descendant cleared2020: 1 descendant cleared2024: 1 descendant cleared1995200020052010201520202025
  1. This deviceK961859 Novus Standard and Pediatric ValvesIntegra Neurocare, LLC · 1996
  2. Descendant · cites it directly · 2 of its ownK020728 Miethke Shunt SystemAesculap, Inc. · 2002 · Recalled
  3. Descendant · cites it directly · 1 of its ownK974708 Gemini Standard and Mini ValvesNeurocare Group · 1998
  4. Descendant · 2 generations on · 0 of its ownK242003 XABO Ventricular Catheter, XABO Peritoneal Catheter, XABO Catheter SetAesculap, Inc. · 2024
  5. Descendant · 2 generations on · 0 of its ownK200950 Ventricular CatheterAesculap, Inc. · 2020
  6. Descendant · cites it directly · 0 of its ownK153041 Bundled Neurological Shunts and Accessories Product Families…Integra LifeSciences Corporation · 2016

Most influential descendants

Showing 5 of 5 · See all
  • K020728Miethke Shunt SystemAesculap, Inc. · 2002 · cites it directly2descendants
  • K974708Gemini Standard and Mini ValvesNeurocare Group · 1998 · cites it directly1descendant
  • K242003XABO Ventricular Catheter, XABO Peritoneal Catheter, XABO Catheter SetAesculap, Inc. · 2024 · 2 generations on0descendants
  • K200950Ventricular CatheterAesculap, Inc. · 2020 · 2 generations on0descendants
  • K153041Bundled Neurological Shunts and Accessories Product Families Labeling Modification to…Integra LifeSciences Corporation · 2016 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K961859Novus Standard and Pediatric ValvesIntegra Neurocare, LLC1996—
+1K020728Miethke Shunt SystemAesculap, Inc.20021
+1K974708Gemini Standard and Mini ValvesNeurocare Group1998—
+2K242003XABO Ventricular Catheter, XABO Peritoneal Catheter, XABO Catheter SetAesculap, Inc.2024—
+2K200950Ventricular CatheterAesculap, Inc.2020—
+1K153041Bundled Neurological Shunts and Accessories Product Families Labeling…Integra LifeSciences Corporation2016—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199810
200210
201610
202010
202410
FIG. 1 — Lineage of K961859, 1996–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JXG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JXG device

  1. #1 K243531 Codman Libertís Shunt Catheter with Bactiseal…score 11.9 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA lists a 510(k) statement for it but has not posted the file, so its predicates are not known.

What descends from it? (5)

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K020728Miethke Shunt SystemAesculap, Inc.20022
K974708Gemini Standard and Mini ValvesNeurocare Group19981
K153041Bundled Neurological Shunts and Accessories Product Families Labeling Modification to…Integra LifeSciences Corporation20160

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K020728 (Aesculap, Inc., 2002) has gone furthest, with 2 descendants of its own.

How does its category compare?

All JXG devices

JXG Shunt, Central Nervous System And Components: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JXG

8in 2025

2007: 32008: 62009: 52010: 32011: 72012: 32013: 32015: 62016: 62017: 72018: 62019: 42020: 22021: 12022: 42023: 52024: 32025: 82026 (partial year): 2
2007high 8 (2025) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JXG

255in 2025

2007: 184 days median2008: 60 days median2009: 106 days median2010: 30 days median2011: 136 days median2012: 78 days median2013: 108 days median2015: 276 days median2016: 143 days median2017: 90 days median2018: 102 days median2019: 101 days median2022: 101 days median2023: 134 days median2024: 90 days median2025: 255 days median
2007high 276 (2015) · low 30 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JXG

3in 2024

2008: 12009: 302011: 52012: 12013: 142014: 62017: 12020: 82023: 22024: 32026 (partial year): 1
2007high 30 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JXG

1,198in 2025

2007: 6492008: 6302009: 6292010: 8122011: 7872012: 9772013: 1,0042014: 1,2512015: 9842016: 1,0912017: 1,3352018: 1,4842019: 1,2952020: 1,2062021: 1,4672022: 1,3292023: 1,2212024: 1,2142025: 1,198
2007high 1,484 (2018) · low 629 (2009)2025

MAUDE reports naming product code JXG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200731840649
20086601630
2009510630629
20103300812
201171365787
20123781977
20133108141,004
20140—61,251
201562760984
2016614301,091
201779011,335
2018610201,484
2019410101,295
20202—81,206
20211—01,467
2022410101,329
2023513421,221
202439031,214
2025825501,198
20262—1—
Cite this page

510(k) Report. “K961859: Novus Standard and Pediatric Valves.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K961859

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026