510(k) · Cleared
ClearedFukuda Denshi Model DS-5100E Portable Patient Monitor
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Fukuda Denshi USA, Inc. · DSI Detector And Alarm, Arrhythmia
Cleared on Oct 3, 1997 as substantially equivalent to K964187 (Fukuda Denshi USA, Inc., 1997) after a 190-day review. Its family tree reaches back 2 generations to 1990. 6 later devices descend from it.
- Decided
- Oct 3, 1997
- Review
- 190 days
- Class
- Class II
- Product code
- DSI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K894628 (1990). 6 later devices descend from it, 1 citing it directly.
- Root · 2 generations backK894628 Model DS-3300 Dynascope Patient MonitorFukuda Denshi USA, Inc. · 1990
- 1 generation backK964187 Fukada Denshi Dynascope Model DS-5300 Patient MonitorFukuda Denshi USA, Inc. · 1997
- This deviceK971131 Fukuda Denshi Model DS-5100E Portable Patient MonitorFukuda Denshi USA, Inc. · 1997
- Descendant · cites it directly · 5 of its ownK032290 Fukuda Denshi Dynascope Model DS-7100 Series Portable Patient MonitorFukuda Denshi USA, Inc. · 2003
- Descendant · 2 generations on · 4 of its ownK040246 Fukuda Denshi Dynascope Model DS-7141 Portable Patient MonitorFukuda Denshi USA, Inc. · 2004
- Descendant · 3 generations on · 3 of its ownK081891 Fukuda Denshi Dynascope Model DS-7000/7000M Patient MonitorFukuda Denshi USA, Inc. · 2008
- Descendant · 4 generations on · 2 of its ownK083697 Fukuda Denshi Dynascope Model DS-7000 Series Patient Monitor, Model…Fukuda Denshi USA, Inc. · 2009
- Descendant · 5 generations on · 0 of its ownK150030 Fukuda Denshi DynaScope Model DS-8000 Series Patient MonitorFukuda Denshi USA, Inc. · 2015
Showing 5 of 6 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 6 · See all- K032290Fukuda Denshi Dynascope Model DS-7100 Series Portable Patient MonitorFukuda Denshi USA, Inc. · 2003 · cites it directly5descendants
- K040246Fukuda Denshi Dynascope Model DS-7141 Portable Patient MonitorFukuda Denshi USA, Inc. · 2004 · 2 generations on4descendants
- K081891Fukuda Denshi Dynascope Model DS-7000/7000M Patient MonitorFukuda Denshi USA, Inc. · 2008 · 3 generations on3descendants
- K083697Fukuda Denshi Dynascope Model DS-7000 Series Patient Monitor, Model…Fukuda Denshi USA, Inc. · 2009 · 4 generations on2descendants
- K150030Fukuda Denshi DynaScope Model DS-8000 Series Patient MonitorFukuda Denshi USA, Inc. · 2015 · 5 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K894628 | Model DS-3300 Dynascope Patient Monitor | Fukuda Denshi USA, Inc. | 1990 | — |
| −1 | K964187 | Fukada Denshi Dynascope Model DS-5300 Patient Monitor | Fukuda Denshi USA, Inc. | 1997 | — |
| 0 (this device) | K971131 | Fukuda Denshi Model DS-5100E Portable Patient Monitor | Fukuda Denshi USA, Inc. | 1997 | — |
| +1 | K032290 | Fukuda Denshi Dynascope Model DS-7100 Series Portable Patient Monitor | Fukuda Denshi USA, Inc. | 2003 | — |
| +2 | K040246 | Fukuda Denshi Dynascope Model DS-7141 Portable Patient Monitor | Fukuda Denshi USA, Inc. | 2004 | — |
| +3 | K081891 | Fukuda Denshi Dynascope Model DS-7000/7000M Patient Monitor | Fukuda Denshi USA, Inc. | 2008 | — |
| +4 | K083697 | Fukuda Denshi Dynascope Model DS-7000 Series Patient Monitor, Model… | Fukuda Denshi USA, Inc. | 2009 | — |
| +5 | K150030 | Fukuda Denshi DynaScope Model DS-8000 Series Patient Monitor | Fukuda Denshi USA, Inc. | 2015 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 1 | 0 |
| 2015 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DSI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DSI device
- #1 K243349 BodyGuardian Remote Monitoring System (BGRMS…score 13.1 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K964187 | Fukada Denshi Dynascope Model DS-5300 Patient Monitor Cleared while this submission was under review Summary page 1…n Name: Portable Patient Monitor Classification Name: Arrhythmia detector and alarm Legally Marketed Device: FUKUDA DENSHI model DS-5300 Patient Monitor, 510(k) number K964187. (The DS-5100E is a modification to the DS-5300, 510(k) number K964187.) July 3, 1997 DS-5100E 510(k) Additional Information K9… | 1997 |
What descends from it? (6)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K032290 | Fukuda Denshi Dynascope Model DS-7100 Series Portable Patient Monitor | 2003 | 5 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 1 company; a new generation was cleared every 7.3 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K032290 (Fukuda Denshi USA, Inc., 2003) has gone furthest, with 5 descendants of its own.
- 3 other devices also cite its predicate K964187.
How does its category compare?
All DSI devicesDSI Detector And Alarm, Arrhythmia: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · DSI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DSI
243in 2019
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DSI
18in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DSI
712in 2025
MAUDE reports naming product code DSI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 7 | 151 | 4 | 64 |
| 2008 | 5 | 70 | 8 | 156 |
| 2009 | 6 | 73 | 3 | 279 |
| 2010 | 6 | 111 | 5 | 823 |
| 2011 | 6 | 114 | 3 | 793 |
| 2012 | 3 | 113 | 1 | 766 |
| 2013 | 1 | — | 0 | 795 |
| 2014 | 4 | 200 | 0 | 1,000 |
| 2015 | 9 | 127 | 0 | 1,645 |
| 2016 | 6 | 224 | 0 | 4,352 |
| 2017 | 0 | — | 0 | 3,594 |
| 2018 | 2 | — | 1 | 3,648 |
| 2019 | 3 | 243 | 4 | 3,485 |
| 2020 | 2 | — | 2 | 3,084 |
| 2021 | 0 | — | 0 | 3,092 |
| 2022 | 0 | — | 1 | 1,638 |
| 2023 | 2 | — | 2 | 1,616 |
| 2024 | 1 | — | 0 | 1,320 |
| 2025 | 1 | — | 18 | 712 |
| 2026 | 1 | — | 1 | — |
What is it indicated for?
Use of the Fukuda Denshi model DS-5100E Portable Patient Monitor system is indicated in those clinical settings where Observations of one or more of the following parameters on an individual patient may be required: ECG (waveform, heart rate, ST-Level, and ventricular arrhythmias), respiration, non-invasive and/or invasive blood pressures, temperature, and/or pulse oximetry. The observations may include an audible and visual alarm if any of these…
Read the full statement (143 words)
Use of the Fukuda Denshi model DS-5100E Portable Patient Monitor system is indicated in those clinical settings where
Observations of one or more of the following parameters on an individual patient may be required: ECG (waveform, heart rate, ST-Level, and ventricular arrhythmias), respiration, non-invasive and/or invasive blood pressures, temperature, and/or pulse oximetry.
The observations may include an audible and visual alarm if any of these parameters exceed values that are establish by the clinician.
The observations may also include the individual or comparative trending of one or more of these parameters over a period of up to 24 hours.
An instantaneous display of waveforms, numeric, and trended values is desired.
a hard copy record of the physiological parameters, the alarmed conditions, or the trended values may be required.
where the patient may need to be monitored while being transported within the healthcare facility.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K971131 · printed Nov 6, 2026
Cite this page
510(k) Report. “K971131: Fukuda Denshi Model DS-5100E Portable Patient Monitor.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K971131
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026