510(k) Report

510(k) · Cleared

Cleared

Ezchek/Hba Blood Collection Kit

K971919510(k) TraditionalCleared Sep 5, 1997105-day reviewClass II21 CFR 864.7470

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Flexsite Diagnostics, Inc. · LCP Assay, Glycosylated Hemoglobin

Cleared on Sep 5, 1997 as substantially equivalent to K861697 (Awareness Technology, Inc., 1986) after a 105-day review. Its family tree reaches back 1 generation to 1986. 11 later devices descend from it.

Decided
Sep 5, 1997
Review
105 days
Class
Class II
Product code
LCP
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K861697 (1986). 11 later devices descend from it, 6 citing it directly.

Descendants, by year cleared 1999: 3 descendants cleared1998: 3 descendants cleared2000: 1 descendant cleared2015: 1 descendant cleared2023: 1 descendant cleared2019: 1 descendant cleared2002: 1 descendant clearedK861697 · Self Assure/GHB (Capillary-Blood Collection Kit) · Awareness Technology, Inc. · 19861990200020102020
Descendants, by generation 1 generation forward: 6 descendants2 generations forward: 2 descendants3 generations forward: 3 descendants K861697 · Self Assure/GHB (Capillary-Blood Collection Kit) · Awareness Technology, Inc. · 19860
  1. Root · 1 generation backK861697 Self Assure/GHB (Capillary-Blood Collection Kit)Awareness Technology, Inc. · 1986
  2. This deviceK971919 Ezchek/Hba Blood Collection KitFlexsite Diagnostics, Inc. · 1997
  3. Descendant · cites it directly · 4 of its ownK984529 Hemochek Sample Collection KitOsborn Laboratories, Inc. · 1999
  4. Descendant · cites it directly · 3 of its ownK990899 Hemochek-A1C Sample Collection KitOsborn Group, Inc. · 1999 · Recalled
  5. Descendant · 2 generations on · 2 of its ownK141944 Home Access Aic TestHome Access Health Corp. · 2015
  6. Descendant · cites it directly · 2 of its ownK983172 Accu-Base Hemoglobin A1C Sample Collection KitDiabetes Technologies, Inc. (Dti) · 1998
  7. Descendant · 2 generations on · 1 of its ownK993787 Appraise-Cardio Sample Collection KitOsborn Group, Inc. · 2000 · Recalled

Showing 5 of 11 descendants. See all descendants

Descendants cleared per year

1998: 31999: 32000: 12002: 12015: 12019: 12023: 1
1998high 3 (1998) · low 0 (2001)2026

Most influential descendants

Showing 5 of 11 · See all
  • K984529Hemochek Sample Collection KitOsborn Laboratories, Inc. · 1999 · cites it directly4descendants
  • K990899Hemochek-A1C Sample Collection KitOsborn Group, Inc. · 1999 · cites it directly3descendants
  • K141944Home Access Aic TestHome Access Health Corp. · 2015 · 2 generations on2descendants
  • K983172Accu-Base Hemoglobin A1C Sample Collection KitDiabetes Technologies, Inc. (Dti) · 1998 · cites it directly2descendants
  • K993787Appraise-Cardio Sample Collection KitOsborn Group, Inc. · 2000 · 2 generations on1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K861697Self Assure/GHB (Capillary-Blood Collection Kit)Awareness Technology, Inc.1986—
0 (this device)K971919Ezchek/Hba Blood Collection KitFlexsite Diagnostics, Inc.1997—
+1K984529Hemochek Sample Collection KitOsborn Laboratories, Inc.1999—
+1K990899Hemochek-A1C Sample Collection KitOsborn Group, Inc.199934
+2K141944Home Access Aic TestHome Access Health Corp.2015—
+1K983172Accu-Base Hemoglobin A1C Sample Collection KitDiabetes Technologies, Inc. (Dti)1998—
+2K993787Appraise-Cardio Sample Collection KitOsborn Group, Inc.20003

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199830
199930
200010
200210
201510
201910
202310
FIG. 1 — Lineage of K971919, 1986–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LCP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LCP device

  1. #1 K221326 Nova Allegro HbA1c Assay, Nova Allegro Analyzerscore 9.6 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K861697Self Assure/GHB (Capillary-Blood Collection Kit)
Summary page 1
…ample Collection Kit Self-monitoring glycohemoglobin (hemoglobin A capillary blood collection kit. Glycosylated Hemoglobin Assay (21C.F.R. 864.7470) Self-Assure®/GHb; K861697/A. The device is a kit containing the materials required to collect a capillary blood sample from a finger-stick on a piece of f…
Awareness Technology, Inc.1986—

Also cleared against K861697: 2 other devices →

What descends from it? (11)

See all 11

6 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K984529Hemochek Sample Collection KitOsborn Laboratories, Inc.19994
K990899Hemochek-A1C Sample Collection KitOsborn Group, Inc.19993
K983172Accu-Base Hemoglobin A1C Sample Collection KitDiabetes Technologies, Inc. (Dti)19982
K974491Accu-Chek A1C Hemoglobin TestBoehringer Mannheim Corp.19981
K991850Safe at-Home Test Kit for Monitoring Hemoglobin AlcBiosafe Laboratories, Inc.19990
K983253Precision A1C Home HBA1C Sample Collection KitMedisense, Inc.19980

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K984529 (Osborn Laboratories, Inc., 1999) has gone furthest, with 4 descendants of its own.
  • 2 other devices also cite its predicate K861697.

How does its category compare?

All LCP devices

LCP Assay, Glycosylated Hemoglobin: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LCP

1in 2024

2007: 72008: 52009: 62010: 22011: 102012: 92013: 22014: 82015: 32016: 22017: 52018: 22019: 42020: 12023: 22024: 1
2007high 10 (2011) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LCP

269in 2019

2007: 133 days median2008: 206 days median2009: 158 days median2011: 176 days median2012: 143 days median2014: 127 days median2015: 239 days median2017: 218 days median2019: 269 days median
2007high 269 (2019) · low 127 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LCP

1in 2025

2007: 12008: 32009: 62010: 52011: 512013: 42014: 22015: 22016: 62017: 12018: 12022: 12024: 12025: 1
2007high 51 (2011) · low 0 (2012)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LCP

22in 2025

2007: 52008: 112009: 152010: 42011: 272012: 512013: 1932014: 1822015: 642016: 292017: 1492018: 1,9112019: 1142020: 132021: 72022: 82023: 272024: 392025: 22
2007high 1,911 (2018) · low 4 (2010)2025

MAUDE reports naming product code LCP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007713315
20085206311
20096158615
20102—54
2011101765127
20129143051
20132—4193
201481272182
20153239264
20162—629
201752181149
20182—11,911
201942690114
20201—013
20210—07
20220—18
20232—027
20241—139
20250—122
20260—0—

What is it indicated for?

For over-the-counter at home or doctor's office use to obtain a finger stick whole blood sample for laboratory testing to monitor jong-term (4-8 weeks) blood sugar control in diabetes. Test results should be evaluated together with a personal doctor. This product is not indicated for the diagnosis of diabetes mellitus.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K971919: Ezchek/Hba Blood Collection Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K971919

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026