510(k) Report

510(k) · Cleared

Cleared

Vacutainer Brand PPT Plasma Preparation Tube

K972075510(k) TraditionalCleared Feb 24, 1998266-day reviewClass II21 CFR 862.1675

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Becton Dickinson Vacutainer Systems · PJE Blood/Plasma Collection Device For Dna Testing

Cleared on Feb 24, 1998 as substantially equivalent to K953463 (Becton Dickinson Vacutainer Systems, 1995) and 1 other predicate after a 266-day review. Its family tree reaches back 1 generation to 1995. 13 later devices descend from it.

Decided
Feb 24, 1998
Review
266 days
Class
Class II
Product code
PJE
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K945952 (1995). 2 ancestors in all. 13 later devices descend from it, 5 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1995: 1 other ancestor2002: 1 descendant cleared2015: 2 descendants cleared2011: 1 descendant cleared2005: 1 descendant cleared2001: 1 descendant cleared2007: 1 descendant cleared2020: 2 descendants cleared2016: 2 descendants cleared2023: 1 descendant cleared2022: 1 descendant clearedK945952 · Vacutainer (R) Brand Plus PST (TM) Plasma Separation Tube · Bd Becton Dickinson Vacutainer Systems Preanalytic · 1995 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 5 descendants2 generations forward: 6 descendants3 generations forward: 2 descendants K945952 · Vacutainer (R) Brand Plus PST (TM) Plasma Separation Tube · Bd Becton Dickinson Vacutainer Systems Preanalytic · 1995 · recalled0
  1. Root · 1 generation backK945952 Vacutainer (R) Brand Plus PST (TM) Plasma Separation TubeBd Becton Dickinson Vacutainer Systems Preanalytic · 1995 · Recalled
  2. This deviceK972075 Vacutainer Brand PPT Plasma Preparation TubeBecton Dickinson Vacutainer Systems · 1998
  3. Descendant · cites it directly · 6 of its ownK110701 Oragene-DX Ogd-500; Oragene-DX Ogd-575; Oragene-DX Oxd-525…DNA Genotek, Inc. · 2011
  4. Descendant · 2 generations on · 3 of its ownK141410 Oragene DX Ogd-500.001DNA Genotek, Inc. · 2015
  5. Descendant · 2 generations on · 2 of its ownK152556 Oragene DxDNA Genotek, Inc. · 2016
  6. Descendant · 2 generations on · 1 of its ownK192920 Oragene®•DxDNA Genotek, Inc. · 2020
  7. Descendant · cites it directly · 1 of its ownK142821 PAXgene Blood DNA TubePreanalytix GmbH · 2015

Showing 5 of 13 descendants. See all descendants

Descendants cleared per year

2001: 12002: 12005: 12007: 12011: 12015: 22016: 22020: 22022: 12023: 1
2001high 2 (2015) · low 0 (2003)2026

Most influential descendants

Showing 5 of 13 · See all
  • K110701Oragene-DX Ogd-500; Oragene-DX Ogd-575; Oragene-DX Oxd-525; Oragene-DX Oyd-500DNA Genotek, Inc. · 2011 · cites it directly6descendants
  • K141410Oragene DX Ogd-500.001DNA Genotek, Inc. · 2015 · 2 generations on3descendants
  • K152556Oragene DxDNA Genotek, Inc. · 2016 · 2 generations on2descendants
  • K192920Oragene®•DxDNA Genotek, Inc. · 2020 · 2 generations on1descendant
  • K142821PAXgene Blood DNA TubePreanalytix GmbH · 2015 · cites it directly1descendant
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K945952Vacutainer (R) Brand Plus PST (TM) Plasma Separation TubeBd Becton Dickinson Vacutainer Systems Preanalytic199510
0 (this device)K972075Vacutainer Brand PPT Plasma Preparation TubeBecton Dickinson Vacutainer Systems1998—
+1K110701Oragene-DX Ogd-500; Oragene-DX Ogd-575; Oragene-DX Oxd-525; Oragene-DX Oyd-500DNA Genotek, Inc.2011—
+2K141410Oragene DX Ogd-500.001DNA Genotek, Inc.2015—
+2K152556Oragene DxDNA Genotek, Inc.2016—
+2K192920Oragene®•DxDNA Genotek, Inc.2020—
+1K142821PAXgene Blood DNA TubePreanalytix GmbH2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200110
200210
200510
200710
201110
201520
201620
202020
202210
202310
FIG. 1 — Lineage of K972075, 1995–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PJE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PJE device

  1. #1 K231469 PAXgene® Blood DNA Tubescore 6.1 · 3 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K953463Vacutainer Plus TubesBecton Dickinson Vacutainer Systems1995—
*K945952Vacutainer (R) Brand Plus PST (TM) Plasma Separation Tube
Summary page 4
…ce " | K-Number | Clearance Date VACUTAINER Systems VACUTAINER® Brand PLUS Tube with | K9853463 9/20/95 EDTA Anticoagulant VACUTAINER Systems VACUTAINER™ Brand PST™ Tube K945952 1/18/95 hn flf‘/ December 4, 1997 chalago Date egu a.tory Affairs Specialist Regulatory Affairs Department DEP…
Bd Becton Dickinson Vacutainer Systems Preanalytic199510

What descends from it? (13)

See all 13

5 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110701Oragene-DX Ogd-500; Oragene-DX Ogd-575; Oragene-DX Oxd-525; Oragene-DX Oyd-500DNA Genotek, Inc.20116
K142821PAXgene Blood DNA TubePreanalytix GmbH20151
K014104Vacuette Edta K2 TubesGreiner Vacuette North America, Inc.20021
K042927Vacuette Edta K3 Evacuated Blood Collection TubesGreiner Bio-One Vacuette North America20050
K012043Vacuette Edta K2 Gel TubesGreiner Vacuette North America, Inc.20010

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K110701 (DNA Genotek, Inc., 2011) has gone furthest, with 6 descendants of its own.

How does its category compare?

All PJE devices

PJE Blood/Plasma Collection Device For Dna Testing: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · PJE

1in 2023

2015: 12023: 1
2007high 1 (2015) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PJE

Too few PJE 510(k)s in any year since 2007 to give a median.

Recalls per year · PJE

No recall names PJE since 2007.

Adverse event reports per year · PJE

257in 2025

2018: 272019: 122020: 32021: 142022: 162023: 632024: 1682025: 257
2007high 257 (2025) · low 0 (2007)2025

MAUDE reports naming product code PJE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20151—00
20160—00
20170—00
20180—027
20190—012
20200—03
20210—014
20220—016
20231—063
20240—0168
20250—0257
20260—0—

What is it indicated for?

The VACUTAINER® Brand PPT™ Plasma Preparation Tube with EDTA anticoagulant and a gel barrier material are evacuated blood collection tubes which provide a means of collecting, processing and transporting blood in a closed plastic tube. When the Tube is used together with VACUTAINER® Brand needles and holders, it is a closed system for the collection of venous blood with the same indications identified here. Blood collected in a tube containing EDTA…

Read the full statement (123 words)

The VACUTAINER® Brand PPT™ Plasma Preparation Tube with EDTA anticoagulant and a gel barrier material are evacuated blood collection tubes which provide a means of collecting, processing and transporting blood in a closed plastic tube. When the Tube is used together with VACUTAINER® Brand needles and holders, it is a closed system for the collection of venous blood with the same indications identified here.

Blood collected in a tube containing EDTA anticoagulant and gel barrier material can be primarily used to provide undiluted plasma for use in molecular diagnostic test methods; including but not limited to Polymerase Chain Reaction (PCR) and branched-DNA (bDNA). The specimen may also be used for other testing that requires an undiluted plasma sample as determined by the laboratory.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K972075: Vacutainer Brand PPT Plasma Preparation Tube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K972075

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026