510(k) · Cleared
ClearedDisposable Patient Return Electrode
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Erbe USA, Inc. · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Jul 9, 1997 after a 22-day review. The FDA summary names no predicate by number. 3 of the 22 devices in its family, counting itself, have a Class I recall. 21 later devices descend from it.
- Decided
- Jul 9, 1997
- Review
- 22 days
- Class
- Class II
- Product code
- GEI
- Recalls
- None
- Predicates
- 0
21 later devices descend from it, 2 citing it directly. 3 of the 22 devices in this family, counting this one, have a Class I recall.
- This deviceK972269 Disposable Patient Return ElectrodeErbe USA, Inc. · 1997
- Descendant · cites it directly · 19 of its ownK030362 Skintact Cool Contact Electrosurgical Grounding PlatesLeonhard Lang GmbH · 2003
- Descendant · 2 generations on · 14 of its ownK063161 Skintact Cool Contact Electrosurgical Grounding Plate with NH 04 GelLeonhard Lang GmbH · 2006
- Descendant · 2 generations on · 4 of its ownK140500 SkintactLeonhard Lang GmbH · 2014
- Descendant · 3 generations on · 4 of its ownK080741 Mega Soft Reusable Patient Return ElectrodeMegadyne Medical Products, Inc. · 2008 · Recalled (Class I)
- Descendant · 3 generations on · 3 of its ownK173877 BOWA Neutral ElectrodesBowa-Electronics GmbH & Co. KG · 2018
Showing 5 of 21 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
Most influential descendants
Showing 5 of 21 · See all- K030362Skintact Cool Contact Electrosurgical Grounding PlatesLeonhard Lang GmbH · 2003 · cites it directly19descendants
- K063161Skintact Cool Contact Electrosurgical Grounding Plate with NH 04 GelLeonhard Lang GmbH · 2006 · 2 generations on14descendants
- K140500SkintactLeonhard Lang GmbH · 2014 · 2 generations on4descendants
- K080741Mega Soft Reusable Patient Return ElectrodeMegadyne Medical Products, Inc. · 2008 · 3 generations on4descendants
- K173877BOWA Neutral ElectrodesBowa-Electronics GmbH & Co. KG · 2018 · 3 generations on3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K972269 | Disposable Patient Return Electrode | Erbe USA, Inc. | 1997 | — |
| +1 | K030362 | Skintact Cool Contact Electrosurgical Grounding Plates | Leonhard Lang GmbH | 2003 | — |
| +2 | K063161 | Skintact Cool Contact Electrosurgical Grounding Plate with NH 04 Gel | Leonhard Lang GmbH | 2006 | — |
| +2 | K140500 | Skintact | Leonhard Lang GmbH | 2014 | — |
| +3 | K080741 | Mega Soft Reusable Patient Return Electrode | Megadyne Medical Products, Inc. | 2008 | Class I |
| +3 | K173877 | BOWA Neutral Electrodes | Bowa-Electronics GmbH & Co. KG | 2018 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2006 | 1 | 0 |
| 2007 | 1 | 0 |
| 2008 | 1 | 1 |
| 2009 | 1 | 0 |
| 2010 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 2 | 1 |
| 2016 | 2 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2024 | 3 | 1 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
3 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
The FDA summary names no predicate by number.
What descends from it? (21)
See all 212 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (3 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K080741Mega Soft Reusable Patient Return ElectrodeMegadyne Medical Products, Inc. · 2008 · 3 generations on · ◆ in the 2008 descendants bar of FIG. 13 Class I recalls
- K133726Mega Soft Universal Patient Return ElectrodeMegadyne Medical Products, Inc. · 2014 · 4 generations on · ◆ in the 2014 descendants bar of FIG. 15 Class I recalls
- K233644Megadyne Patient Return Electrode Pad - Universal Dual (model 0846), Megadyne Patient Return Electrode Pad -…Megadyne Medical Products, Inc. · 2024 · 5 generations on · ◆ in the 2024 descendants bar of FIG. 13 Class I recalls
What does this lineage say?
- Of its descendants, K030362 (Leonhard Lang GmbH, 2003) has gone furthest, with 19 descendants of its own.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
ERBE Disposable Patient Return Electrodes are Indicated for Use only in conjunction with Electrosurgical Generators for cutting and coagulation of human tissue.
The Electrodes are for use with Generators with Return Electrode Safety Systems (divided contact surface) and Generators without Return Electrode Safety Systems (single contact surface).
The Electrodes must be applied as close as possible to the operative site, preferably on the thigh or upper arm of the patient, and must not be applied to scars, infected skin, bony protrusions, or over metal implants.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K972269 · printed Nov 6, 2026
Cite this page
510(k) Report. “K972269: Disposable Patient Return Electrode.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K972269
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026