510(k) Report

510(k) · Cleared

Cleared

Divan Anesthesia Ventilator

K980208510(k) TraditionalCleared Aug 4, 1998196-day reviewClass II21 CFR 868.5895

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Draeger Medical, Inc. · CBK Ventilator, Continuous, Facility Use

Cleared on Aug 4, 1998 as substantially equivalent to K953228 (Draeger Medical, Inc., 1996) after a 196-day review. Its family tree reaches back 1 generation to 1996. 2 of the 14 devices in its family, counting itself, have a Class I recall. 12 later devices descend from it.

Decided
Aug 4, 1998
Review
196 days
Class
Class II
Product code
CBK
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K953228 (1996). 12 later devices descend from it, 2 citing it directly. 2 of the 14 devices in this family, counting this one, have a Class I recall.

Descendants, by year cleared 1999: 1 descendant cleared2004: 1 descendant cleared2015: 2 descendants cleared2014: 2 descendants cleared, 1 with a Class I recall12023: 1 descendant cleared, 1 with a Class I recall12018: 1 descendant cleared2021: 1 descendant cleared2019: 1 descendant cleared2026: 2 descendants clearedK953228 · Narkomed AV2+ Anesthesia Ventilator · Draeger Medical, Inc. · 19961995200020052010201520202025
Descendants, by generation 1 generation forward: 2 descendants2 generations forward: 4 descendants, 1 with a Class I recall13 generations forward: 2 descendants, 1 with a Class I recall14 generations forward: 3 descendants5 generations forward: 1 descendant K953228 · Narkomed AV2+ Anesthesia Ventilator · Draeger Medical, Inc. · 19960+5
  1. Root · 1 generation backK953228 Narkomed AV2+ Anesthesia VentilatorDraeger Medical, Inc. · 1996
  2. This deviceK980208 Divan Anesthesia VentilatorDraeger Medical, Inc. · 1998
  3. Descendant · cites it directly · 11 of its ownK983635 Julian Anesthesia Workstation, Model # JulianDraeger Medical, Inc. · 1999
  4. Descendant · cites it directly · 10 of its ownK042607 Primus USDraeger Medical, Inc. · 2004 · Recalled
  5. Descendant · 2 generations on · 5 of its ownK142552 A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015
  6. Descendant · 2 generations on · 4 of its ownK151954 A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · Recalled
  7. Descendant · 3 generations on · 3 of its ownK171292 A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2018

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

1999: 12004: 12014: 22015: 22018: 12019: 12021: 12023: 12026: 2
1999high 2 (2014) · low 0 (2000)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 12 · See all
  • K983635Julian Anesthesia Workstation, Model # JulianDraeger Medical, Inc. · 1999 · cites it directly11descendants
  • K042607Primus USDraeger Medical, Inc. · 2004 · cites it directly10descendants
  • K142552A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · 2 generations on5descendants
  • K151954A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2015 · 2 generations on4descendants
  • K171292A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2018 · 3 generations on3descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K953228Narkomed AV2+ Anesthesia VentilatorDraeger Medical, Inc.1996—
0 (this device)K980208Divan Anesthesia VentilatorDraeger Medical, Inc.1998—
+1K983635Julian Anesthesia Workstation, Model # JulianDraeger Medical, Inc.1999—
+1K042607Primus USDraeger Medical, Inc.20042
+2K142552A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2015—
+2K151954A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.20153
+3K171292A7 Anesthesia SystemShenzhen Mindray Bio-Medical Electronics Co., Ltd.2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
200410
201421
201520
201810
201910
202110
202311
202620
FIG. 1 — Lineage of K980208, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CBK device

  1. #1 K252663 Inbentus Versatilescore 16.0 · 17 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K953228Narkomed AV2+ Anesthesia Ventilator
Summary page 1
…y Road Telford, Pennsylvania 18969 Establishment Registration Number: 2517967 Devices to which substantial equivalence is claimed: Narkomed AV2+ Anesthesia Ventilator K953228 Device Description: The Divan is an electronic ventilator with an integrated breathing system , and operator control panel. In…
Draeger Medical, Inc.1996—

Also cleared against K953228: 1 other device →

What descends from it? (12)

See all 12

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K983635Julian Anesthesia Workstation, Model # JulianDraeger Medical, Inc.199911
K042607Primus USDraeger Medical, Inc.200410

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K133886Perseus A500Draeger Medical GmbH · 2014 · 2 generations on · ◆ in the 2014 descendants bar of FIG. 12 Class I recalls
  • K230931AtlanDrägerwerk AG Co. Kgaa · 2023 · 3 generations on · ◆ in the 2023 descendants bar of FIG. 18 Class I recalls

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K983635 (Draeger Medical, Inc., 1999) has gone furthest, with 11 descendants of its own.
  • 1 other device also cites its predicate K953228.

How does its category compare?

All CBK devices

CBK Ventilator, Continuous, Facility Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CBK

4in 2025

2007: 112008: 182009: 122010: 142011: 132012: 172013: 52014: 52015: 72016: 42017: 62018: 42019: 82020: 52021: 62023: 52024: 92025: 42026 (partial year): 3
2007high 18 (2008) · low 0 (2022)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CBK

163in 2025

2007: 142 days median2008: 115 days median2009: 122 days median2010: 150 days median2011: 192 days median2012: 207 days median2013: 277 days median2014: 439 days median2015: 266 days median2016: 323 days median2017: 280 days median2018: 183 days median2019: 435 days median2020: 176 days median2021: 267 days median2023: 309 days median2024: 203 days median2025: 163 days median2026 (partial year): 235 days median
2007high 439 (2014) · low 115 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CBK

14in 2024

2007: 172008: 232009: 82010: 92011: 122012: 2, 1 Class I2013: 5, 2 Class I2014: 5, 4 Class I2015: 6, 4 Class I2016: 4, 1 Class I2017: 12018: 3, 3 Class I2019: 14, 13 Class I2020: 42021: 21, 19 Class I2022: 8, 4 Class I2023: 4, 3 Class I2024: 14, 14 Class I2026 (partial year): 15, 13 Class I
2007high 23 (2008) · low 0 (2025)2026

Class I (81 since 2007) Class II/III not classified

Adverse event reports per year · CBK

13,991in 2025

2007: 1,5312008: 1,9332009: 1,7662010: 1,7992011: 1,8772012: 5,5092013: 7,9212014: 7,6002015: 11,8762016: 16,0562017: 14,4512018: 9,8492019: 9,1002020: 11,0962021: 13,3222022: 15,9742023: 24,9282024: 20,3362025: 13,991
2007high 24,928 (2023) · low 1,531 (2007)2025

MAUDE reports naming product code CBK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200711142171,531
200818115231,933
20091212281,766
20101415091,799
201113192121,877
2012172072 (1)5,509
201352775 (2)7,921
201454395 (4)7,600
201572666 (4)11,876
201643234 (1)16,056
20176280114,451
201841833 (3)9,849
2019843514 (13)9,100
20205176411,096
2021626721 (19)13,322
20220—8 (4)15,974
202353094 (3)24,928
2024920314 (14)20,336
20254163013,991
2026323515 (13)—

What is it indicated for?

The Divan is indicated for ventilating patients as an integrated part of specific North American Driger anesthesia machines. Federal law restricts this device to sale by or on the order of a physician.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K980208: Divan Anesthesia Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K980208

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026