Careside Glucose

K981183510(k) TraditionalCleared May 7, 199836-day reviewClass II21 CFR 862.1345

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Exigent Diagnostics, Inc. · CGA Glucose Oxidase, Glucose

Cleared on May 7, 1998 as substantially equivalent to K912844 (Eastman Kodak Company, 1991) after a 36-day review. Its family tree reaches back 1 generation to 1991.

Decided
May 7, 1998
Review
36 days
Class
Class II
Product code
CGA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K912844 (1991). No later device cites it as a predicate yet.

K912844 · Kodak Ektachem Dtii System · Eastman Kodak Company · 1991199019921994199619982000
K912844 · Kodak Ektachem Dtii System · Eastman Kodak Company · 19910
  1. Root · 1 generation backK912844 Kodak Ektachem Dtii SystemEastman Kodak Company · 1991
  2. This deviceK981183 Careside GlucoseExigent Diagnostics, Inc. · 1998
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K912844Kodak Ektachem Dtii SystemEastman Kodak Company1991—
0 (this device)K981183Careside GlucoseExigent Diagnostics, Inc.1998—
FIG. 1 — Lineage of K981183, 1991–1998Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CGA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CGA device

  1. #1 K252488 ABL90 FLEX PLUS Systemscore 12.8 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K912844Kodak Ektachem Dtii System
Summary page 1
…d Johnson’s (formerly Eastman Kodak, Inc.) Vitros Glu Slides for Johnson and Johnson'’s Vitros DT 60 (formerly Eastman Kodak’s DT 60 II). Predicate Device 510K number: K912844/A Product Code: 75CGA Exigent Diagnostics, Inc. Page 11 IV. CareSide™ Glucose Premarket Notification March 31,…
Eastman Kodak Company1991—

Also cleared against K912844: 28 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 28 other devices also cite its predicate K912844.

How does its category compare?

All CGA devices

CGA Glucose Oxidase, Glucose: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CGA

2in 2024

2007: 72008: 62009: 102010: 82011: 92012: 102013: 32014: 52015: 42016: 42017: 22018: 22019: 22020: 22021: 12022: 12023: 42024: 22026 (partial year): 1
2007high 10 (2009) · low 0 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CGA

249in 2023

2007: 122 days median2008: 56 days median2009: 155 days median2010: 122 days median2011: 217 days median2012: 123 days median2013: 441 days median2014: 265 days median2015: 150 days median2016: 157 days median2023: 249 days median
2007high 441 (2013) · low 56 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CGA

3in 2023

2007: 22008: 22009: 42010: 62011: 32013: 32014: 22015: 6, 2 Class I2016: 22019: 12023: 3
2007high 6 (2010) · low 0 (2012)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · CGA

59in 2025

2007: 292008: 372009: 752010: 1722011: 4232012: 2332013: 1722014: 1222015: 1552016: 362017: 922018: 692019: 1162020: 682021: 482022: 2722023: 1,1412024: 2662025: 59
2007high 1,141 (2023) · low 29 (2007)2025

MAUDE reports naming product code CGA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20077122229
2008656237
200910155475
201081226172
201192173423
2012101230233
201334413172
201452652122
201541506 (2)155
20164157236
20172—092
20182—069
20192—1116
20202—068
20211—048
20221—0272
2023424931,141
20242—0266
20250—059
20261—0—

What is it indicated for?

For in vitro diagnostic use with Exigent Diagnostics’ CareSide™ Analyzer to measure glucose from anti-coagulated whole blood, plasma or serum specimens to aid in the diagnosis and management of disorders of blood glucose regulation such as diabetes.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981183: Careside Glucose.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K981183

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026