Careside Analyzer

K980056510(k) TraditionalCleared Mar 6, 199859-day reviewClass I21 CFR 862.2170

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Exigent Diagnostics, Inc. · JJF Analyzer, Chemistry, Micro, For Clinical Use

Cleared on Mar 6, 1998 as substantially equivalent to K912844 (Eastman Kodak Company, 1991) after a 59-day review. Its family tree reaches back 1 generation to 1991. 1 later device descends from it.

Decided
Mar 6, 1998
Review
59 days
Class
Class I
Product code
JJF
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K912844 (1991). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 1999: 1 descendant clearedK912844 · Kodak Ektachem Dtii System · Eastman Kodak Company · 19911990200020102020
Descendants, by generation 1 generation forward: 1 descendant K912844 · Kodak Ektachem Dtii System · Eastman Kodak Company · 19910
  1. Root · 1 generation backK912844 Kodak Ektachem Dtii SystemEastman Kodak Company · 1991
  2. This deviceK980056 Careside AnalyzerExigent Diagnostics, Inc. · 1998
  3. Descendant · cites it directly · 0 of its ownK993634 Careside AnalyzerCareside, Inc. · 1999

Most influential descendants

Showing 1 of 1 · See all
  • K993634Careside AnalyzerCareside, Inc. · 1999 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K912844Kodak Ektachem Dtii SystemEastman Kodak Company1991—
0 (this device)K980056Careside AnalyzerExigent Diagnostics, Inc.1998—
+1K993634Careside AnalyzerCareside, Inc.1999—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
199910
FIG. 1 — Lineage of K980056, 1991–1999Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K912844Kodak Ektachem Dtii System
Summary page 1
…T 60 II/DTSC II Module. Name of Predicate Device: Johnson and Johnson’s Vitros DT 60 II/DTSC I/ (formerly Kodak Ektachem DT 60 II System) Predicate Device S10K number: K 912844/A Product Code: 751JE Exigent Diagnostics, Inc. Page 14a CareSide™ Analyzer Premarket Notification revised on…
Eastman Kodak Company1991—

Also cleared against K912844: 28 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K993634Careside AnalyzerCareside, Inc.19990

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K993634 (Careside, Inc., 1999) has gone furthest, with 0 descendants of its own.
  • 28 other devices also cite its predicate K912844.

How does its category compare?

All JJF devices

JJF Analyzer, Chemistry, Micro, For Clinical Use: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · JJF

FDA has decided no JJF device since 2007.

Median 510(k) review, days · JJF

Too few JJF 510(k)s in any year since 2007 to give a median.

Recalls per year · JJF

2in 2018

2007: 22012: 32018: 2
2007high 3 (2012) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJF

2in 2025

2007: 102008: 22009: 32010: 212011: 192012: 82013: 12014: 32022: 12023: 12025: 2
2007high 21 (2010) · low 0 (2015)2025

MAUDE reports naming product code JJF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—210
20080—02
20090—03
20100—021
20110—019
20120—38
20130—01
20140—03
20150—00
20160—00
20170—00
20180—20
20190—00
20200—00
20210—00
20220—01
20230—01
20240—00
20250—02
20260—0—

What is it indicated for?

For in vitro diagnostic use by professionals with Exigent Diagnostics Cartridges for the in vitro measurement of various clinical chemistry analytes in human blood.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K980056: Careside Analyzer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K980056

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026