510(k) Report

510(k) · Cleared

Cleared

Outlook Large Phased Array Neck Coil

K981959510(k) TraditionalCleared Jul 31, 199857-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Philips Medical Systems (Cleveland), Inc. · MOS Coil, Magnetic Resonance, Specialty

Cleared on Jul 31, 1998 as substantially equivalent to K964678 (Philips Medical Systems (Cleveland), Inc., 1997) and 1 other predicate after a 57-day review. Its family tree reaches back 2 generations to 1993.

Decided
Jul 31, 1998
Review
57 days
Class
Class II
Product code
MOS
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K925987 (1993). 4 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestor1995: 1 other ancestorK925987 · Instrumentarium MEGA4 HT · Instrumentarium Imaging, Inc. · 1993K964678 · Phased Array Neck Coil · Philips Medical Systems (Cleveland), Inc. · 1997199019921994199619982000
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 1 other ancestor K964678 · Phased Array Neck Coil · Philips Medical Systems (Cleveland), Inc. · 1997K925987 · Instrumentarium MEGA4 HT · Instrumentarium Imaging, Inc. · 19930
  1. Root · 2 generations backK925987 Instrumentarium MEGA4 HTInstrumentarium Imaging, Inc. · 1993
  2. 1 generation backK964678 Phased Array Neck CoilPhilips Medical Systems (Cleveland), Inc. · 1997
  3. This deviceK981959 Outlook Large Phased Array Neck CoilPhilips Medical Systems (Cleveland), Inc. · 1998
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K925987Instrumentarium MEGA4 HTInstrumentarium Imaging, Inc.1993—
−1K964678Phased Array Neck CoilPhilips Medical Systems (Cleveland), Inc.1997—
0 (this device)K981959Outlook Large Phased Array Neck CoilPhilips Medical Systems (Cleveland), Inc.1998—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199710
FIG. 1 — Lineage of K981959, 1993–1998Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOS device

  1. #1 K253738 3.0T Air 32CH Hnascore 15.2 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K964678Phased Array Neck Coil
Summary page 2
…lowing chart has been compiled to demonstrate the substantial equivalence of these devices. Predicate Device Parameter Large Phased Arra.y Picker - Outlook Neck Coil (K964678) Neck Coil USALI - Profile 7000 Neck Coil (K964531) Compatibility Picker 0.23T Outlook system | Hitachi 1.5T MRH-1500 system . (S…
Philips Medical Systems (Cleveland), Inc.1997—
*K964531Profile 70000 Quadrature Volume Neck Coil
Summary page 2
…substantial equivalence of these devices. Predicate Device Parameter Large Phased Arra.y Picker - Outlook Neck Coil (K964678) Neck Coil USALI - Profile 7000 Neck Coil (K964531) Compatibility Picker 0.23T Outlook system | Hitachi 1.5T MRH-1500 system . (See K964531) Enclosyre Material Same. Royalite R59 A…
Us Asia Instruments, Inc.1997—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 2 companies; a new generation was cleared every 3.7 years on median.
  • None of the 4 ancestors has a recall.

How does its category compare?

All MOS devices

MOS Coil, Magnetic Resonance, Specialty: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MOS

3in 2025

2007: 162008: 192009: 102010: 162011: 252012: 152013: 72014: 122015: 62016: 112017: 92018: 102019: 32020: 52021: 42022: 112023: 102024: 102025: 32026 (partial year): 10
2007high 25 (2011) · low 3 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOS

59in 2025

2007: 19 days median2008: 33 days median2009: 43 days median2010: 78 days median2011: 57 days median2012: 49 days median2013: 87 days median2014: 60 days median2015: 58 days median2016: 42 days median2017: 63 days median2018: 30 days median2019: 178 days median2020: 51 days median2021: 41 days median2022: 79 days median2023: 59 days median2024: 39 days median2025: 59 days median2026 (partial year): 45 days median
2007high 178 (2019) · low 19 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOS

13in 2024

2008: 22010: 12012: 12015: 22019: 82020: 12024: 13
2007high 13 (2024) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MOS

2in 2025

2007: 42008: 22009: 52010: 132011: 72012: 122013: 102014: 42015: 52016: 72017: 92018: 72019: 82020: 22021: 32022: 52023: 42024: 82025: 2
2007high 13 (2010) · low 2 (2008)2025

MAUDE reports naming product code MOS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007161904
2008193322
2009104305
20101678113
2011255707
20121549112
2013787010
2014126004
201565825
2016114207
201796309
2018103007
2019317888
202055112
202144103
2022117905
2023105904
20241039138
202535902
202610450—

What is it indicated for?

The Picker Outlook system is intended for use as a NMR device that produces images that: (1) correspond to the distribution of protons exhibiting NMR, (2) depend upon the NMR parameters (proton density, flow velocity, spin-lattice relaxation time (T1), and spin-spin relaxation time (T2)) and 3) display the soft tissue structure of the head and whole body. When interpreted by a trained physician, these images yield information that can be useful in the determination of a diagnosis.

The Large Phased Array Neck Coil is indicated for use in providing coverage of the neck, from the cerebellum to the upper thoracic spine region.

Anatomic Regions: Neck

Nuclei Excited: Hydrogen

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K981959: Outlook Large Phased Array Neck Coil.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K981959

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026