510(k) · Cleared
Recalled · Class II · 2020Modular Protusio Cup
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomet, Inc. · JDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
Cleared on Feb 18, 1999 as substantially equivalent to K911718 (Biomet, Inc., 1991) and 4 other predicates after a 43-day review. Its family tree reaches back 3 generations to 1995. 1 later device descends from it. It has been recalled once.
- Decided
- Feb 18, 1999
- Review
- 43 days
- Class
- Class II
- Product code
- JDI
- Recalls
- 1
- Predicates
- 5
Its longest line of descent runs back 3 generations to K953578 (1995). 7 ancestors in all, the oldest K911718 (1991). 1 later device descends from it, 1 citing it directly.
- Root · 3 generations backK953578 Protek Acetabular Roof Reinforcement RingIntermedics Orthopedics · 1995
- 2 generations backK960678 Burch/Schneider Reinforcement CageIntermedics Orthopedics · 1996
- 1 generation backK971890 Recovery Protrusio CageBiomet, Inc. · 1997 · Recalled
- This deviceK990032 Modular Protusio CupBiomet, Inc. · 1999
- Descendant · cites it directly · 0 of its ownK992359 MRS-TitanRotec Medizintechnik GmbH · 2000
Most influential descendants
Showing 1 of 1 · See all- K992359MRS-TitanRotec Medizintechnik GmbH · 2000 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K953578 | Protek Acetabular Roof Reinforcement Ring | Intermedics Orthopedics | 1995 | — |
| −2 | K960678 | Burch/Schneider Reinforcement Cage | Intermedics Orthopedics | 1996 | — |
| −1 | K971890 | Recovery Protrusio Cage | Biomet, Inc. | 1997 | 1 |
| 0 (this device) | K990032 | Modular Protusio Cup | Biomet, Inc. | 1999 | — |
| +1 | K992359 | MRS-Titan | Rotec Medizintechnik GmbH | 2000 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1991 | 1 | 0 |
| 1992 | 1 | 0 |
| 1994 | 1 | 0 |
| 1996 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDI device
- #1 K253515 Zimmer Biomet OSS™ Orthopedic Salvage System…score 15.2 · 12 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (5)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K911718 | M.a.R.a. (Modular Acetabular Reconstruction Syst)Summary page 2…in overall design and intended function. The following devices are predicates to the Modular Protrusio Cup: Biomet’s Modular Acetabular Reconstructive System (M.A.R.S) (K911718), Biomet’s Healy Revision Component System (K921139), Biomet’s Recovery protrusio Cage (K971890), Osteonics’ Restoration GAP Acet… | 1991 |
| * | K921139 | Healey Revision Component SystemSummary page 2…ing devices are predicates to the Modular Protrusio Cup: Biomet’s Modular Acetabular Reconstructive System (M.A.R.S) (K911718), Biomet’s Healy Revision Component System (K921139), Biomet’s Recovery protrusio Cage (K971890), Osteonics’ Restoration GAP Acetabular Cup (K943549), and Intermedics’ Orthopaedics’… | 1992 |
| * | K971890 | Recovery Protrusio CageSummary page 2…otrusio Cup: Biomet’s Modular Acetabular Reconstructive System (M.A.R.S) (K911718), Biomet’s Healy Revision Component System (K921139), Biomet’s Recovery protrusio Cage (K971890), Osteonics’ Restoration GAP Acetabular Cup (K943549), and Intermedics’ Orthopaedics’ Burch/Schneider Reinforcement Cage (K960678… | 1997 |
| * | K943549 | Restoration Acetabular CupSummary page 2…ve System (M.A.R.S) (K911718), Biomet’s Healy Revision Component System (K921139), Biomet’s Recovery protrusio Cage (K971890), Osteonics’ Restoration GAP Acetabular Cup (K943549), and Intermedics’ Orthopaedics’ Burch/Schneider Reinforcement Cage (K960678). 00065 *” “l"c""b & <, _5 -/é DEP… | 1994 |
| * | K960678 | Burch/Schneider Reinforcement CageSummary page 2…139), Biomet’s Recovery protrusio Cage (K971890), Osteonics’ Restoration GAP Acetabular Cup (K943549), and Intermedics’ Orthopaedics’ Burch/Schneider Reinforcement Cage (K960678). 00065 *” “l"c""b & <, _5 -/é DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service 3 %, o Food and Dru… | 1996 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K992359 | MRS-Titan | 2000 | 0 |
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Nov 25, 2020 | Class II | Z-0627-2021 | Process control | Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 2 companies; a new generation was cleared every 1.3 years on median.
- 1 of the 7 ancestors has a recall of any class.
- Of its descendants, K992359 (Rotec Medizintechnik GmbH, 2000) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K911718.
How does its category compare?
All JDI devicesJDI Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDI
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · JDI
59in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · JDI
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDI
1,644in 2025
MAUDE reports naming product code JDI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 81 | 26 | 696 |
| 2008 | 5 | 96 | 6 | 810 |
| 2009 | 3 | 65 | 3 | 964 |
| 2010 | 0 | — | 3 | 2,040 |
| 2011 | 2 | — | 5 | 3,160 |
| 2012 | 4 | 167 | 4 | 5,122 |
| 2013 | 3 | 176 | 11 | 5,206 |
| 2014 | 3 | 98 | 3 | 4,968 |
| 2015 | 3 | 190 | 1 | 4,906 |
| 2016 | 4 | 166 | 5 | 3,995 |
| 2017 | 1 | — | 5 | 6,135 |
| 2018 | 1 | — | 1 | 6,728 |
| 2019 | 2 | — | 1 | 7,407 |
| 2020 | 7 | 247 | 77 | 4,015 |
| 2021 | 3 | 162 | 0 | 3,170 |
| 2022 | 3 | 69 | 0 | 1,978 |
| 2023 | 2 | — | 0 | 1,635 |
| 2024 | 3 | 59 | 0 | 1,821 |
| 2025 | 1 | — | 1 | 1,644 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The indications for the Modular Protrusio Cup are as follows:
1) Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis.
2) Rheumatoid arthritis
3) Correction of functional deformity
4) Treatment of nonunion, femoral neck fractures, and throchanteric fractures of the proximal femur with head involvement, unmanageable using other techniques
5) Revision of failed joint construction or treatment
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K990032 · printed Nov 4, 2026
Cite this page
510(k) Report. “K990032: Modular Protusio Cup.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K990032
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026