510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

Anatomica Glenoid Component

K990136510(k) TraditionalCleared Mar 1, 199946-day reviewClass II21 CFR 888.3660Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sulzer Orthopedics, Inc. · KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented

Cleared on Mar 1, 1999 after a 46-day review. The FDA summary names its predicate without a number. 135 later devices descend from it. It has been recalled 2 times.

Decided
Mar 1, 1999
Review
46 days
Class
Class II
Product code
KWS
Recalls
2
Predicates
0

135 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2005: 1 descendant cleared2004: 2 descendants cleared2017: 5 descendants cleared2011: 9 descendants cleared2007: 1 descendant cleared2012: 8 descendants cleared2010: 8 descendants cleared2018: 10 descendants cleared2006: 2 descendants cleared2015: 6 descendants cleared2014: 5 descendants cleared2020: 4 descendants cleared2008: 1 descendant cleared2013: 6 descendants cleared2021: 8 descendants cleared2025: 10 descendants cleared2022: 9 descendants cleared2016: 6 descendants cleared2019: 8 descendants cleared2023: 10 descendants cleared2026: 8 descendants cleared2024: 8 descendants cleared1995200020052010201520202025
  1. This deviceK990136 Anatomica Glenoid ComponentSulzer Orthopedics, Inc. · 1999
  2. Descendant · cites it directly · 130 of its ownK032126 Promos ShoulderPlus Orthopedics · 2004
  3. Descendant · cites it directly · 71 of its ownK042021 Exactech Equinoxe Shoulder SystemExactech, Inc. · 2004 · Recalled
  4. Descendant · 2 generations on · 67 of its ownK063578 Promos Modular Shoulder SystemPlus Orthopedics AG · 2007 · Recalled
  5. Descendant · 3 generations on · 52 of its ownK081016 Smith & Nephew, Inc., Promos Reverse Shoulder SystemSmith & Nephew, Inc. · 2008 · Recalled
  6. Descendant · 4 generations on · 44 of its ownK110598 SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011 · Recalled

Showing 5 of 135 descendants. See all descendants

Descendants cleared per year

2004: 22005: 12006: 22007: 12008: 12010: 82011: 92012: 82013: 62014: 52015: 62016: 62017: 52018: 102019: 82020: 42021: 82022: 92023: 102024: 82025: 102026: 8
2004high 10 (2018) · low 0 (2009)2026

Most influential descendants

Showing 5 of 135 · See all
  • K032126Promos ShoulderPlus Orthopedics · 2004 · cites it directly130descendants
  • K042021Exactech Equinoxe Shoulder SystemExactech, Inc. · 2004 · cites it directly71descendants
  • K063578Promos Modular Shoulder SystemPlus Orthopedics AG · 2007 · 2 generations on67descendants
  • K081016Smith & Nephew, Inc., Promos Reverse Shoulder SystemSmith & Nephew, Inc. · 2008 · 3 generations on52descendants
  • K110598SMR Reverse Shoulder SystemLima Corporate S.P.A. · 2011 · 4 generations on44descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K990136Anatomica Glenoid ComponentSulzer Orthopedics, Inc.1999—
+1K032126Promos ShoulderPlus Orthopedics2004—
+1K042021Exactech Equinoxe Shoulder SystemExactech, Inc.200410
+2K063578Promos Modular Shoulder SystemPlus Orthopedics AG20074
+3K081016Smith & Nephew, Inc., Promos Reverse Shoulder SystemSmith & Nephew, Inc.20082
+4K110598SMR Reverse Shoulder SystemLima Corporate S.P.A.20111

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200420
200510
200620
200710
200810
201080
201190
201280
201360
201450
201560
201660
201750
2018100
201980
202040
202180
202290
2023100
202480
2025100
202680
FIG. 1 — Lineage of K990136, 1999–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KWS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KWS device

  1. #1 K220847 AETOS Shoulder Systemscore 21.1 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (7)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*—Sulzer Orthopedics Select Shoulder Curved Back Pegged Glenoid
Named without a submission number
—
*—Orthomet/3M Modular Neer II Shoulder System
Named without a submission number
—
*—Zimmer Fenlin Total Shoulder
Named without a submission number
—
*—Smith & Nephew Richards Cofield Shoulder
Named without a submission number
—
*—Kirschner/Biomet Atlas Shoulder
Named without a submission number
—
*—Biomet Bio-Modular Total Shoulder
Named without a submission number
—
*—Depuy Global Total Shoulder System
Named without a submission number
—

What descends from it? (135)

See all 135

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K032126Promos ShoulderPlus Orthopedics2004130
K042021Exactech Equinoxe Shoulder SystemExactech, Inc.200471
K051623Anatomical Shoulder Keeled GlenoidZimmer GmbH20053
K170711ASHCOM Shoulder System, Anatomical Shoulder System and Anatomical Shoulder Combined SystemZimmer GmbH20172

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 4, 2012Class IIZ-0226-2013Error in labelingZimmer Inc., is initiating a correction to the patient labels of products manufactured before March 20I0 by the Zimmer GmbH production site in Winterthur, Switzerland, after receiving four complaints of a discrepancy between product…
Jun 25, 2007Not classifiedZ-1194-2007OtherThe package actually contains a knee patellar implant.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K032126 (Plus Orthopedics, 2004) has gone furthest, with 130 descendants of its own.

How does its category compare?

All KWS devices

KWS Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · KWS

3in 2025

2007: 22008: 42009: 42010: 72011: 112012: 72013: 122014: 72015: 82016: 102017: 72018: 42019: 92020: 32021: 52022: 52023: 42024: 22025: 32026 (partial year): 2
2007high 12 (2013) · low 2 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KWS

97in 2025

2008: 37 days median2009: 108 days median2010: 33 days median2011: 90 days median2012: 86 days median2013: 120 days median2014: 89 days median2015: 129 days median2016: 114 days median2017: 120 days median2018: 152 days median2019: 106 days median2020: 98 days median2021: 151 days median2022: 158 days median2023: 250 days median2025: 97 days median
2007high 250 (2023) · low 33 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KWS

2in 2023

2007: 212008: 292010: 102011: 112012: 102014: 12016: 12017: 42018: 12019: 22020: 52023: 22026 (partial year): 1
2007high 29 (2008) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KWS

2,281in 2025

2007: 1582008: 2382009: 2942010: 3932011: 4862012: 5422013: 8182014: 1,0662015: 1,1702016: 9702017: 1,6812018: 1,5452019: 1,7282020: 1,5672021: 1,3582022: 1,2682023: 1,7502024: 2,1222025: 2,281
2007high 2,281 (2025) · low 158 (2007)2025

MAUDE reports naming product code KWS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—21158
200843729238
200941080294
201073310393
2011119011486
201278610542
2013121200818
201478911,066
2015812901,170
2016101141970
2017712041,681
2018415211,545
2019910621,728
202039851,567
2021515101,358
2022515801,268
2023425021,750
20242—02,122
202539702,281
20262—1—

What is it indicated for?

The Anatomica All-Poly Glenoid component is intended for cemented use in treatment of the following:

1. Advanced wear and tear of the shoulder joint resulting from degenerative, posttraumatic or rheumatoid arthritis.

Omarthrosis.

Rheumatoid arthritis.

Revision of shoulder prosthesis.

Traumatology: the only cone to be used in traumatological indications is the traumatology cone.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K990136: Anatomica Glenoid Component.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K990136

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026