510(k) Report

510(k) · Cleared

Cleared

Eye Trak TM, Computerized Electronystagmograph (Eng), Model Etv-XXXX

K991642510(k) AbbreviatedCleared Aug 3, 199982-day reviewClass II21 CFR 882.1460

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bertec Corp. · GWN Nystagmograph

Cleared on Aug 3, 1999 after an 82-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Aug 3, 1999
Review
82 days
Class
Class II
Product code
GWN
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K991642Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWN device

  1. #1 K260566 SMARTVERTIGO™ Vestibular Assessment Systemscore 12.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All GWN devices

GWN Nystagmograph: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GWN

3in 2025

2007: 22008: 12009: 12013: 32015: 32016: 22017: 42018: 32019: 12020: 22023: 12025: 32026 (partial year): 1
2007high 4 (2017) · low 0 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWN

203in 2025

2013: 88 days median2015: 165 days median2017: 160 days median2018: 87 days median2025: 203 days median
2007high 203 (2025) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWN

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWN

1in 2025

2012: 22018: 12019: 52021: 12022: 12023: 32024: 42025: 1
2007high 5 (2019) · low 0 (2007)2025

MAUDE reports naming product code GWN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20081—00
20091—00
20100—00
20110—00
20120—02
201338810
20140—00
2015316500
20162—00
2017416000
201838701
20191—05
20202—00
20210—01
20220—01
20231—03
20240—04
2025320301
20261—0—

What is it indicated for?

The EyeTrak™ is used to non-invasively measure the vertical and horizontal eye movements during a variety of tests performed during electronystagmography (ENG) testing. This testing includes, but is not limited to: saccadic test, smooth pursuit, optokinetic nystagmus, and kinetic vestibular tests. It provides a trained clinician with data and graphs representing a patient's ability to perform certain eye movements voluntarily, as well as the patient's…

Read the full statement (230 words)

The EyeTrak™ is used to non-invasively measure the vertical and horizontal eye movements during a variety of tests performed during electronystagmography (ENG) testing. This testing includes, but is not limited to: saccadic test, smooth pursuit, optokinetic nystagmus, and kinetic vestibular tests. It provides a trained clinician with data and graphs representing a patient's ability to perform certain eye movements voluntarily, as well as the patient's involuntary eye movements due to head movement, eye movement and/or body movement as is normally performed in vestibular diagnostic testing such as in Hallpike positional tests. It is used, then, to aide in the detection and diagnosis of vestibular disorders.

The EyeTrak™ does not incorporate a camera for vertical and horizontal eye movement measurement, therefore it is not as cumbersome as other similar devices, and does not have focal length and resolution limitations based on the camera and camera lens used. The EyeTrak™ instead measures horizontal and vertical eye movement non-invasively using infra-red sensors and an IR oculography method with background light suppression. This allows for direct transmission of sensor signals to a processing unit, which in turn provides the signals to the software for processing, saving, and presentation. A camera and monitor can be used to monitor torsional eye movements, and a sensor can be added to measure head movement.

The results are used to provide documentation of a patient’s performance on specific tests.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K991642: Eye Trak TM, Computerized Electronystagmograph (Eng), Model Etv-XXXX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K991642

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026