510(k) Report

510(k) · Cleared

Cleared

Criterion 40 or PM 40

K992101510(k) TraditionalCleared Jan 6, 2000198-day reviewClass II21 CFR 868.2600

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Caradyne, Ltd. · CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm)

Cleared on Jan 6, 2000 as substantially equivalent to K871083 (Canadian Monaghan, Ltd., 1987) and 3 other predicates after a 198-day review. Its family tree reaches back 1 generation to 1987. 6 later devices descend from it.

Decided
Jan 6, 2000
Review
198 days
Class
Class II
Product code
CAP
Recalls
None
Predicates
4

Its longest line of descent runs back 1 generation to K871083 (1987). 4 ancestors in all. 6 later devices descend from it, 4 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1993: 2 other ancestors1987: 1 other ancestor2023: 2 descendants cleared2018: 1 descendant cleared2019: 1 descendant cleared2013: 1 descendant cleared2025: 1 descendant clearedK871083 · CM 5000 Monitor Airway Pressure · Canadian Monaghan, Ltd. · 19871990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors 1 generation forward: 4 descendants2 generations forward: 2 descendants K871083 · CM 5000 Monitor Airway Pressure · Canadian Monaghan, Ltd. · 19870
  1. Root · 1 generation backK871083 CM 5000 Monitor Airway PressureCanadian Monaghan, Ltd. · 1987
  2. This deviceK992101 Criterion 40 or PM 40Caradyne, Ltd. · 2000
  3. Descendant · cites it directly · 2 of its ownK221734 Maxtec MaxO2 ME+pMaxtec, LLC · 2023
  4. Descendant · 2 generations on · 0 of its ownK251245 OxyMinder Pro (10310)Bio-Med Device, Inc. · 2025
  5. Descendant · 2 generations on · 0 of its ownK231895 Maxtec MaxBlend2+pMaxtec, LLC · 2023
  6. Descendant · cites it directly · 0 of its ownK182292 VORTRAN APM-PlusVortran Medical Technology 1, Inc. · 2019
  7. Descendant · cites it directly · 0 of its ownK172284 NAPA LP-15 Airway Pressure MonitorDrw Medical, LLC · 2018

Showing 5 of 6 descendants. See all descendants

Descendants cleared per year

2013: 12018: 12019: 12023: 22025: 1
2013high 2 (2023) · low 0 (2014)2026

Most influential descendants

Showing 5 of 6 · See all
  • K221734Maxtec MaxO2 ME+pMaxtec, LLC · 2023 · cites it directly2descendants
  • K251245OxyMinder Pro (10310)Bio-Med Device, Inc. · 2025 · 2 generations on0descendants
  • K231895Maxtec MaxBlend2+pMaxtec, LLC · 2023 · 2 generations on0descendants
  • K182292VORTRAN APM-PlusVortran Medical Technology 1, Inc. · 2019 · cites it directly0descendants
  • K172284NAPA LP-15 Airway Pressure MonitorDrw Medical, LLC · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K871083CM 5000 Monitor Airway PressureCanadian Monaghan, Ltd.1987—
0 (this device)K992101Criterion 40 or PM 40Caradyne, Ltd.2000—
+1K221734Maxtec MaxO2 ME+pMaxtec, LLC2023—
+2K251245OxyMinder Pro (10310)Bio-Med Device, Inc.2025—
+2K231895Maxtec MaxBlend2+pMaxtec, LLC2023—
+1K182292VORTRAN APM-PlusVortran Medical Technology 1, Inc.2019—
+1K172284NAPA LP-15 Airway Pressure MonitorDrw Medical, LLC2018—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
199320

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201810
201910
202320
202510
FIG. 1 — Lineage of K992101, 1987–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CAP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CAP device

  1. #1 K201666 Single Use Manometerscore 0.3 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K871083CM 5000 Monitor Airway Pressure
Summary page 1
…Classification Name: Airway Pressure Monitor (includes gauges and / or alarm) Device: Criterion 40 Predicate Devices: Monaghan, Ltd. CM 5000 Airway Pressure Monitor - K871083 R I TR . e Lo r i Toinindibraatodiaaadubhs waisdn SUSTAHIHRT I The Criterion 40 is a microprocessor controlled device that mea…
Canadian Monaghan, Ltd.1987—
*K873953CM 5000R Remote Airway Pressure
Summary page 4
…viewed as substantially equivalent to the following predicate device - Monaghan CM 5000 Airway Pressure Monitor (APM) cleared under K871083 and other modifications under K873953, K925673, and K931394. The differences between the Criterion 40 and the predicate device are minimal. There are no significant d…
Canadian Monaghan, Ltd.1987—
*K925673Airway Pressure Monitor CM 5000 Ngan
Summary page 4
…substantially equivalent to the following predicate device - Monaghan CM 5000 Airway Pressure Monitor (APM) cleared under K871083 and other modifications under K873953, K925673, and K931394. The differences between the Criterion 40 and the predicate device are minimal. There are no significant difference…
Canadian Monaghan, Ltd.1993—
*K931394CM5000R Remote Indicator
Summary page 4
…y equivalent to the following predicate device - Monaghan CM 5000 Airway Pressure Monitor (APM) cleared under K871083 and other modifications under K873953, K925673, and K931394. The differences between the Criterion 40 and the predicate device are minimal. There are no significant differences that affect…
Canadian Monaghan, Ltd.1993—

What descends from it? (6)

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K221734Maxtec MaxO2 ME+pMaxtec, LLC20232
K182292VORTRAN APM-PlusVortran Medical Technology 1, Inc.20190
K172284NAPA LP-15 Airway Pressure MonitorDrw Medical, LLC20180
K122627Gio Digital Pressure GuagesGalemed Corp.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 4 ancestors has a recall.
  • Of its descendants, K221734 (Maxtec, LLC, 2023) has gone furthest, with 2 descendants of its own.

How does its category compare?

All CAP devices

CAP Monitor, Airway Pressure (Includes Gauge And/Or Alarm): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · CAP

1in 2020

2008: 12010: 12011: 22012: 12013: 22014: 12015: 12016: 12018: 12019: 22020: 1
2007high 2 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CAP

Too few CAP 510(k)s in any year since 2007 to give a median.

Recalls per year · CAP

No recall names CAP since 2007.

Adverse event reports per year · CAP

2in 2025

2009: 12012: 32019: 42020: 12021: 52022: 62023: 112024: 112025: 2
2007high 11 (2023) · low 0 (2007)2025

MAUDE reports naming product code CAP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20090—01
20101—00
20112—00
20121—03
20132—00
20141—00
20151—00
20161—00
20170—00
20181—00
20192—04
20201—01
20210—05
20220—06
20230—011
20240—011
20250—02
20260—0—

What is it indicated for?

Is intended to measure airway pressure when used with positive pressure devices. The device alarms when the airway pressure falls outside of the user selected high and low alarm limits and displays peak pressure and real-time airway pressures. It may be used with positive pressure devices which do not include pressure measurement capabilities, e.g. resuscitation bags or basic ventilators, or as an independent backup pressure monitor for devcies with pressure measurement capability. Environment of use is hospital, home, and sub-acute institutions. The device has been designed for stationary and intra-institution transport only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992101: Criterion 40 or PM 40.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K992101

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026