510(k) Report

510(k) · Cleared

Cleared

Dinamap Pro Series Monitor, Models 100, 200, 300, 400

K992638510(k) TraditionalCleared Feb 24, 2000202-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Critikon Company, LLC · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Feb 24, 2000 as substantially equivalent to K955113 (Johnson & Johnson Medical, Inc., 1996) and 2 other predicates after a 202-day review. Its family tree reaches back 3 generations to 1989. 1 of the 54 devices in its family, counting itself, has a Class I recall. 40 later devices descend from it.

Decided
Feb 24, 2000
Review
202 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
3

Its longest line of descent runs back 3 generations to K896030 (1989). 13 ancestors in all. 40 later devices descend from it, 4 citing it directly. 1 of the 54 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1995: 2 other ancestors1994: 1 other ancestor1992: 1 other ancestor1991: 4 other ancestors1990: 1 other ancestor2002: 4 descendants cleared2007: 3 descendants cleared2006: 1 descendant cleared2010: 3 descendants cleared2009: 1 descendant cleared2014: 4 descendants cleared, 1 with a Class I recall12013: 3 descendants cleared2021: 2 descendants cleared2012: 1 descendant cleared2022: 2 descendants cleared2017: 4 descendants cleared2016: 1 descendant cleared2015: 3 descendants cleared2019: 2 descendants cleared2024: 2 descendants cleared2020: 2 descendants cleared2018: 1 descendant cleared2025: 1 descendant clearedK896030 · Hewlett-Packard Model M1016A CO2 & M1017A FI02 · Hewlett-Packard Co. · 1989K955113 · Dinamap Select Multi-Parameter System · Johnson & Johnson Medical, Inc. · 1996K971569 · Dinamap MPS Portable Monitor · Johnson & Johnson Medical, Inc. · 19971990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 9 other ancestors 1 generation forward: 4 descendants2 generations forward: 6 descendants3 generations forward: 5 descendants4 generations forward: 5 descendants5 generations forward: 7 descendants6 generations forward: 5 descendants, 1 with a Class I recall17 generations forward: 6 descendants8 generations forward: 2 descendants K971569 · Dinamap MPS Portable Monitor · Johnson & Johnson Medical, Inc. · 1997K955113 · Dinamap Select Multi-Parameter System · Johnson & Johnson Medical, Inc. · 1996K896030 · Hewlett-Packard Model M1016A CO2 & M1017A FI02 · Hewlett-Packard Co. · 19890+5
  1. Root · 3 generations backK896030 Hewlett-Packard Model M1016A CO2 & M1017A FI02Hewlett-Packard Co. · 1989
  2. 2 generations backK955113 Dinamap Select Multi-Parameter SystemJohnson & Johnson Medical, Inc. · 1996
  3. 1 generation backK971569 Dinamap MPS Portable MonitorJohnson & Johnson Medical, Inc. · 1997
  4. This deviceK992638 Dinamap Pro Series Monitor, Models 100, 200, 300, 400Critikon Company, LLC · 2000
  5. Descendant · cites it directly · 22 of its ownK014255 Dinamap Procare Series Monitor; Model 100, 200, 300, 400Ge Medical Systems Information Technologies · 2002
  6. Descendant · 2 generations on · 21 of its ownK022193 Dinamap Procare Series Monitor, Models 100N, 200N, 300N, 400NGe Medical Systems Information Technologies · 2002
  7. Descendant · 3 generations on · 20 of its ownK073203 Carescape V100Ge Medical Systems Information Technologies · 2007
  8. Descendant · cites it directly · 13 of its ownK063055 VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006
  9. Descendant · 4 generations on · 11 of its ownK102426 Carescape Model V100 Vital Signs MonitorGe Medical Systems Information Technologies · 2010

Showing 5 of 40 descendants. See all descendants

Descendants cleared per year

2002: 42006: 12007: 32009: 12010: 32012: 12013: 32014: 42015: 32016: 12017: 42018: 12019: 22020: 22021: 22022: 22024: 22025: 1
2002high 4 (2002) · low 0 (2003)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 40 · See all
  • K014255Dinamap Procare Series Monitor; Model 100, 200, 300, 400Ge Medical Systems Information Technologies · 2002 · cites it directly22descendants
  • K022193Dinamap Procare Series Monitor, Models 100N, 200N, 300N, 400NGe Medical Systems Information Technologies · 2002 · 2 generations on21descendants
  • K073203Carescape V100Ge Medical Systems Information Technologies · 2007 · 3 generations on20descendants
  • K063055VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006 · cites it directly13descendants
  • K102426Carescape Model V100 Vital Signs MonitorGe Medical Systems Information Technologies · 2010 · 4 generations on11descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K896030Hewlett-Packard Model M1016A CO2 & M1017A FI02Hewlett-Packard Co.1989—
−2K955113Dinamap Select Multi-Parameter SystemJohnson & Johnson Medical, Inc.1996—
−1K971569Dinamap MPS Portable MonitorJohnson & Johnson Medical, Inc.1997—
0 (this device)K992638Dinamap Pro Series Monitor, Models 100, 200, 300, 400Critikon Company, LLC2000—
+1K014255Dinamap Procare Series Monitor; Model 100, 200, 300, 400Ge Medical Systems Information Technologies2002—
+2K022193Dinamap Procare Series Monitor, Models 100N, 200N, 300N, 400NGe Medical Systems Information Technologies2002—
+3K073203Carescape V100Ge Medical Systems Information Technologies2007—
+1K063055VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd.2006—
+4K102426Carescape Model V100 Vital Signs MonitorGe Medical Systems Information Technologies2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
199140
199210
199410
199520
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200240
200610
200730
200910
201030
201210
201330
201441
201530
201610
201740
201810
201920
202020
202120
202220
202420
202510
FIG. 1 — Lineage of K992638, 1989–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K955113Dinamap Select Multi-Parameter System
Summary page 1
…an internal lead-acid rechargeable battery. The device uses the same technology and materials as the predicate devices, the DINAMAP MPS™ Select™ Multiparameter System (K955113 cleared 8/15/96); the DINAMAP MPS™ Select™ Portable Monitor (K971569 cleared 9/19/97); and the DINAMAP® Compact Monitor (K970182…
Johnson & Johnson Medical, Inc.1996—
*K971569Dinamap MPS Portable Monitor
Summary page 1
…technology and materials as the predicate devices, the DINAMAP MPS™ Select™ Multiparameter System (K955113 cleared 8/15/96); the DINAMAP MPS™ Select™ Portable Monitor (K971569 cleared 9/19/97); and the DINAMAP® Compact Monitor (K970182 cleared 8/18/97). Critikon Company LLC e 4110 George Road ¢ Tampa, F…
Johnson & Johnson Medical, Inc.1997—
*K970182Dinamap Compact Monitor
Summary page 1
…MAP MPS™ Select™ Multiparameter System (K955113 cleared 8/15/96); the DINAMAP MPS™ Select™ Portable Monitor (K971569 cleared 9/19/97); and the DINAMAP® Compact Monitor (K970182 cleared 8/18/97). Critikon Company LLC e 4110 George Road ¢ Tampa, Florida 33634 « Telephone 813-237-2033 CRILLE…
Johnson & Johnson Medical, Inc.1997—

Also cleared against K955113: 2 other devices →

What descends from it? (40)

See all 40

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K014255Dinamap Procare Series Monitor; Model 100, 200, 300, 400Ge Medical Systems Information Technologies200222
K063055VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd.200613
K020022Dinamap Pro Series Monitor, Models 110, 210, 310, 410Ge Medical Systems Information Technologies20021
K070342Clinical Electronic Thermometer, Models TP11403 Through TP11413American I.V. Products, Inc.20070

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K133576Monitor B40Ge Medical Systems China Co., Ltd. · 2014 · 6 generations on · ◆ in the 2014 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 2.4 years on median.
  • 1 of the 13 ancestors has a recall of any class.
  • Of its descendants, K014255 (Ge Medical Systems Information Technologies, 2002) has gone furthest, with 22 descendants of its own.
  • 2 other devices also cite its predicate K955113.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

The DINAMAP® Pro Series 100, 200, 300, 400 Monitor is intended to monitor a single adult, pediatric or neonatal patient’s vital signs. Vital signs parameters include non-invasive blood pressure (systolic, diastolic, and mean arterial pressure), pulse rate and/or temperature and/or oxygen saturation (pulse oximetry). The portable device is designed for use in numerous clinical settings in various hospital departments such as emergency, radiology, recovery, medical/surgical, labor and delivery, endoscopy, cardiac step-down. It can also be used in satellite areas, physicians’ offices, or alternate care settings.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992638: Dinamap Pro Series Monitor, Models 100, 200, 300, 400.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992638

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026