510(k) Report

510(k) · Cleared

Cleared

Midmark M4*9 Easyclave Steam Sterilizer

K992744510(k) TraditionalCleared Jan 10, 2000147-day reviewClass II21 CFR 880.6880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Midmark Corp. · FLE Sterilizer, Steam

Cleared on Jan 10, 2000 as substantially equivalent to K990189 (Midmark Corp., 1999) after a 147-day review. Its family tree reaches back 2 generations to 1994. 1 later device descends from it.

Decided
Jan 10, 2000
Review
147 days
Class
Class II
Product code
FLE
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K936181 (1994). 1 later device descends from it, 1 citing it directly.

  1. Root · 2 generations backK936181 Midmark M-11 Ultraclave Steam SterilizerMidmark Corp. · 1994 · Recalled
  2. 1 generation backK990189 Modification of: Midmark M-11 Ultraclave Steam SterilizerMidmark Corp. · 1999
  3. This deviceK992744 Midmark M4*9 Easyclave Steam SterilizerMidmark Corp. · 2000
  4. Descendant · cites it directly · 0 of its ownK024133 CLS-2000 UnitDentsply Intl. · 2003

Most influential descendants

Showing 1 of 1 · See all
  • K024133CLS-2000 UnitDentsply Intl. · 2003 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K936181Midmark M-11 Ultraclave Steam SterilizerMidmark Corp.19941
−1K990189Modification of: Midmark M-11 Ultraclave Steam SterilizerMidmark Corp.1999—
0 (this device)K992744Midmark M4*9 Easyclave Steam SterilizerMidmark Corp.2000—
+1K024133CLS-2000 UnitDentsply Intl.2003—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200310
FIG. 1 — Lineage of K992744, 1994–2003Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K990189Modification of: Midmark M-11 Ultraclave Steam Sterilizer
Summary page 1
…M4+9 EasyClave Steam Sterilizer claims equivalence: Midmark M-11 UltraClave Steam Sterilizer with dental handpiece indications for use, cleared for marketing 4/19/99 on K990189 ' Device Description: The Midmark M4+9 EasyClave Steam Sterilizer uses saturated steam at high pressures and temperatures and t…
Midmark Corp.1999—

Also cleared against K990189: 4 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K024133CLS-2000 UnitDentsply Intl.20030

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 6 years and passes through 1 company; a new generation was cleared every 4.4 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K024133 (Dentsply Intl., 2003) has gone furthest, with 0 descendants of its own.
  • 4 other devices also cite its predicate K990189.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The M4+9 EasyClave is to be used in medical and dental offices, hospitals, clinics, nursing homes, laboratories, and other facilities to sterilize heat and moisture stable items (including dental handpieces) that are compatible with steam sterilization at 270°F. Refer to Standard Cycle Parameters below for detailed information. Standard Cycle Parameters Cycle Temp/Press/Time Items to be Sterilized (minimums) (Always consult the item manufacturer’s…

Read the full statement (168 words)

The M4+9 EasyClave is to be used in medical and dental offices, hospitals, clinics, nursing homes, laboratories, and other facilities to sterilize heat and moisture stable items (including dental handpieces) that are compatible with steam sterilization at 270°F. Refer to Standard Cycle Parameters below for detailed information.

Standard Cycle Parameters

Cycle Temp/Press/Time Items to be Sterilized

(minimums) (Always consult the item manufacturer’s recommendations for sterilization.)

Unwrapped 132°C (270°F)/ Instruments and dental handpieces loose on a tray. 186 kPa (27 psi) Open glass or metal canisters. Cassettes. Tubing 3:30 minutes not used in surgical procedures. Items that are compatible with a maximum temperature of 135° C (276° F). The sterility of unwrapped items is compromised on exposure to a non-sterile environment.

Wrapped 132°C (270°F)/ Instruments and dental handpieces. Loosely 186 kPa (27 psi) wrapped individual instruments. Multiple layers of 9 minutes instruments separated by fabric. Wrapped trays of loose instruments. Wrapped cassettes. Tubing not used in surgical procedures. Items that are compatible with a maximum temperature of 135°C (276°F).

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K992744: Midmark M4*9 Easyclave Steam Sterilizer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K992744

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026