510(k) Report

510(k) · Cleared

Recalled · Class II · 2022

Olympus Xcyf-1T3 Oes Cystofiberscope/Nephrofiberscope Accessories and Ancillary Equipment

K993041510(k) TraditionalCleared Mar 30, 2000202-day reviewClass II21 CFR 876.1500Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

The Olympus Optical Co. · FAJ Cystoscope And Accessories, Flexible/Rigid

Cleared on Mar 30, 2000 as substantially equivalent to K843084 (Olympus Corp., 1985) and 1 other predicate after a 202-day review. Its family tree reaches back 1 generation to 1985. 5 of the 274 devices in its family, counting itself, have a Class I recall. 271 later devices descend from it. It has been recalled once.

Decided
Mar 30, 2000
Review
202 days
Class
Class II
Product code
FAJ
Recalls
1
Predicates
2

Its longest line of descent runs back 1 generation to K843084 (1985). 2 ancestors in all. 271 later devices descend from it, 3 citing it directly. 5 of the 274 devices in this family, counting this one, have a Class I recall.

Other ancestors, by year clearedDescendants, by year cleared 1992: 1 other ancestor2017: 7 descendants cleared2003: 2 descendants cleared2002: 1 descendant cleared2006: 2 descendants cleared2016: 4 descendants cleared2018: 13 descendants cleared2005: 1 descendant cleared2004: 2 descendants cleared2012: 6 descendants cleared2010: 2 descendants cleared2013: 7 descendants cleared, 1 with a Class I recall12014: 7 descendants cleared2020: 22 descendants cleared2021: 16 descendants cleared, 1 with a Class I recall12019: 18 descendants cleared, 1 with a Class I recall12009: 2 descendants cleared2022: 17 descendants cleared2023: 25 descendants cleared2024: 37 descendants cleared, 1 with a Class I recall12026: 27 descendants cleared2015: 9 descendants cleared2025: 43 descendants cleared, 1 with a Class I recall12007: 1 descendant clearedK843084 · Olympus CHP-P10 Nephroscope/Cystoscope · Olympus Corp. · 1985 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 5 descendants3 generations forward: 10 descendants, 1 with a Class I recall14 generations forward: 49 descendants5 generations forward: 69 descendants, 2 with a Class I recall26 generations forward: 47 descendants, 1 with a Class I recall17 generations forward: 40 descendants, 1 with a Class I recall18 generations forward: 29 descendants9 generations forward: 10 descendants10 generations forward: 6 descendants11 generations forward: 3 descendants K843084 · Olympus CHP-P10 Nephroscope/Cystoscope · Olympus Corp. · 1985 · recalled0+5+10
  1. Root · 1 generation backK843084 Olympus CHP-P10 Nephroscope/CystoscopeOlympus Corp. · 1985 · Recalled
  2. This deviceK993041 Olympus Xcyf-1T3 Oes Cystofiberscope/Nephrofiberscope Accessories…The Olympus Optical Co. · 2000
  3. Descendant · cites it directly · 268 of its ownK021074 Visera Cystovideoscope Olympus Cyf Type V/VAOlympus America, Inc. · 2002
  4. Descendant · 2 generations on · 158 of its ownK062049 Evis Exera II 180 SystemOlympus Medical Systems Corporation · 2006
  5. Descendant · 3 generations on · 132 of its ownK100584 Evis Exeraii 180 SystemOlympus Medical Systems Corporation · 2010 · Recalled
  6. Descendant · 2 generations on · 103 of its ownK030960 Ecn Electronic Video CystonephroscopeAcmi Corporation · 2003
  7. Descendant · 3 generations on · 101 of its ownK042225 Acmi Invisio Icn, Models Icn-0564 and Icn-0565Acmi Corporation · 2004

Showing 5 of 271 descendants. See all descendants

Descendants cleared per year

2002: 12003: 22004: 22005: 12006: 22007: 12009: 22010: 22012: 62013: 72014: 72015: 92016: 42017: 72018: 132019: 182020: 222021: 162022: 172023: 252024: 372025: 432026: 27
2002high 43 (2025) · low 0 (2008)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 271 · See all
  • K021074Visera Cystovideoscope Olympus Cyf Type V/VAOlympus America, Inc. · 2002 · cites it directly268descendants
  • K062049Evis Exera II 180 SystemOlympus Medical Systems Corporation · 2006 · 2 generations on158descendants
  • K100584Evis Exeraii 180 SystemOlympus Medical Systems Corporation · 2010 · 3 generations on132descendants
  • K030960Ecn Electronic Video CystonephroscopeAcmi Corporation · 2003 · 2 generations on103descendants
  • K042225Acmi Invisio Icn, Models Icn-0564 and Icn-0565Acmi Corporation · 2004 · 3 generations on101descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K843084Olympus CHP-P10 Nephroscope/CystoscopeOlympus Corp.19851
0 (this device)K993041Olympus Xcyf-1T3 Oes Cystofiberscope/Nephrofiberscope Accessories and…The Olympus Optical Co.2000—
+1K021074Visera Cystovideoscope Olympus Cyf Type V/VAOlympus America, Inc.2002—
+2K062049Evis Exera II 180 SystemOlympus Medical Systems Corporation2006—
+3K100584Evis Exeraii 180 SystemOlympus Medical Systems Corporation20109
+2K030960Ecn Electronic Video CystonephroscopeAcmi Corporation2003—
+3K042225Acmi Invisio Icn, Models Icn-0564 and Icn-0565Acmi Corporation2004—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200210
200320
200420
200510
200620
200710
200920
201020
201260
201371
201470
201590
201640
201770
2018130
2019181
2020220
2021161
2022170
2023250
2024371
2025431
2026270
FIG. 1 — Lineage of K993041, 1985–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

5 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FAJ device

  1. #1 K193095 Ambu aScope 4 Cystoscore 31.5 · 9 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K843084Olympus CHP-P10 Nephroscope/Cystoscope
Summary page 5
…ympus XCYF - 1T3 OES Cystofiberscope/Nephrofiberscope Accessories and Ancillary Equipment Cystofiberscope/Nephrofiberscope 21 CFR 876.1500 Endoscopes and Accessories K843084 Olympus Nephroscope/Cystoscope K904940 Infant Resectoscope & Accessories The Olympus XCYF-1T3 OES CYSTOFIBERSCOPE/NEPHROFIBERSC…
Olympus Corp.19851
*K904940Olympus Infant Resectoscope and Accessories
Summary page 5
…phrofiberscope Accessories and Ancillary Equipment Cystofiberscope/Nephrofiberscope 21 CFR 876.1500 Endoscopes and Accessories K843084 Olympus Nephroscope/Cystoscope K904940 Infant Resectoscope & Accessories The Olympus XCYF-1T3 OES CYSTOFIBERSCOPE/NEPHROFIBERSCOPE has been specifically designed to…
Olympus Corp.1992—
*—Olympus XCYF-113
Named without a submission number
—
*—Olympus Nephroscope/Cystoscope Model CHF-P10
Named without a submission number
—

Also cleared against K843084: 2 other devices →

What descends from it? (271)

See all 271

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K021074Visera Cystovideoscope Olympus Cyf Type V/VAOlympus America, Inc.2002268
K171916Single Use Hot Biopsy Forceps FD-231Olympus Medical Systems Corp.20170
K032092Olympus Xcyf-TP3 Cystofiberscope/NephrofiberscopeOlympus Optical Co., Ltd.20030

Has anything in its family been recalled? (5 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 20, 2022Class IIZ-1262-2022Nonconforming Material/ComponentIncorrect adhesive used to secure the diopter ring and nameplate ring. Improperly connected diopter ring may result in the loss of adjustment function leading to a blurred field of vision and unintentional contact with the patients body…

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K121959Evis Exera Iii Video SystemOlympus Medical Systems Corp. · 2013 · 3 generations on · ◆ in the 2013 descendants bar of FIG. 18 Class I recalls
  • K183419EVIS EXERA III Bronchovideoscope Olympus BF-XT190Olympus Medical Systems Corp. · 2019 · 5 generations on · ◆ in the 2019 descendants bar of FIG. 12 Class I recalls
  • K250862Evis Exera Iii Bronchovideoscope (Olympus BF-XP190); Evis Exera Iii Bronchovideoscope (Olympus BF-P190)…Olympus Medical Systems Corp. · 2025 · 5 generations on · ◆ in the 2025 descendants bar of FIG. 14 Class I recalls
  • K201758EVIS EXERA III Bronchovideoscope Olympus BF-XP190, EVIS EXERA III Bronchovideoscope Olympus BF-P190Olympus Medical Systems Corp. · 2021 · 6 generations on · ◆ in the 2021 descendants bar of FIG. 11 Class I recall
  • K233472CVAC Aspiration System + CVAC Image ProcessorCalyxo, Inc. · 2024 · 7 generations on · ◆ in the 2024 descendants bar of FIG. 11 Class I recall

What does this lineage say?

  • 1 of the 2 ancestors has a recall of any class.
  • Of its descendants, K021074 (Olympus America, Inc., 2002) has gone furthest, with 268 descendants of its own.
  • 2 other devices also cite its predicate K843084.

How does its category compare?

All FAJ devices

FAJ Cystoscope And Accessories, Flexible/Rigid: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · FAJ

8in 2025

2007: 22009: 22010: 12012: 12014: 12016: 12017: 22018: 22019: 32020: 22021: 32022: 52023: 52024: 92025: 82026 (partial year): 5
2007high 9 (2024) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FAJ

98in 2025

2019: 207 days median2021: 127 days median2022: 170 days median2023: 207 days median2024: 130 days median2025: 98 days median2026 (partial year): 123 days median
2007high 207 (2019) · low 98 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FAJ

7in 2023

2017: 12022: 12023: 7
2007high 7 (2023) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FAJ

2,690in 2025

2007: 92008: 102009: 102010: 92011: 132012: 82013: 122014: 62015: 282016: 752017: 792018: 792019: 1022020: 3392021: 4942022: 7442023: 9202024: 8922025: 2,690
2007high 2,690 (2025) · low 6 (2014)2025

MAUDE reports naming product code FAJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—09
20080—010
20092—010
20101—09
20110—013
20121—08
20130—012
20141—06
20150—028
20161—075
20172—179
20182—079
201932070102
20202—0339
202131270494
202251701744
202352077920
202491300892
202589802,690
202651230—

What is it indicated for?

These instruments have been designed to be used with an Olympus Light Source, Documentation Equipment, Display Monitor, Suction Pump, Endo—Therapy Accessories, elecrosurgical Unit, and other ancillary equipment for endoscopic diagnosis and treatment within the bladder, urethra, and kidneys.

Do not use this instrument for any purpose other than its intended use.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K993041: Olympus Xcyf-1T3 Oes Cystofiberscope/Nephrofiberscope Accessories and Ancillary Equipment.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K993041

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026