510(k) Report

510(k) · Cleared

Cleared

Coulter Hematology Analyzers with Irf & MRV Analyses

K993356510(k) TraditionalCleared Apr 20, 2000197-day reviewClass II21 CFR 864.5220

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Coulter Corp. · GKZ Counter, Differential Cell

Cleared on Apr 20, 2000 as substantially equivalent to K971736 (Sysmex Corp., 1997) and 2 other predicates after a 197-day review. Its family tree reaches back 2 generations to 1988.

Decided
Apr 20, 2000
Review
197 days
Class
Class II
Product code
GKZ
Recalls
None
Predicates
3

Its longest line of descent runs back 2 generations to K885093 (1988). 5 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1997: 1 other ancestor1993: 2 other ancestorsK885093 · Coulter STKS · Coulter Electronics, Inc. · 1988K962988 · Coulter Gen-S System · Coulter Corp. · 1996 · recalled1985199019952000
Other ancestors, by generation 1 generation back: 2 other ancestors2 generations back: 1 other ancestor K962988 · Coulter Gen-S System · Coulter Corp. · 1996 · recalledK885093 · Coulter STKS · Coulter Electronics, Inc. · 19880
  1. Root · 2 generations backK885093 Coulter STKSCoulter Electronics, Inc. · 1988
  2. 1 generation backK962988 Coulter Gen-S SystemCoulter Corp. · 1996 · Recalled
  3. This deviceK993356 Coulter Hematology Analyzers with Irf & MRV AnalysesCoulter Corp. · 2000
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K885093Coulter STKSCoulter Electronics, Inc.1988—
−1K962988Coulter Gen-S SystemCoulter Corp.19964
0 (this device)K993356Coulter Hematology Analyzers with Irf & MRV AnalysesCoulter Corp.2000—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199320
199710
FIG. 1 — Lineage of K993356, 1988–2000Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKZ device

  1. #1 K250943 Sysmex XR-Series (XR-10) Automated Hematology…score 13.2 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K971736Sysmex Immature Reticulocyte Fraction (Irf) Parameter
Summary page 1
…to identify and classify one or more of the formed elements of blood. (CFR 864.5220) .The Classification Number is 81GKZ. Predicate Device(s) Sysmex™ w/IRF Parameter (K971736/S1), COULTER® GEN-S™ System (K962988), COULTER® New Methylene Blue Prep Retic MAXM/AL Analyzers (K925344) Description The Immat…
Sysmex Corp.1997—
*K962988Coulter Gen-S System
Summary page 1
…of the formed elements of blood. (CFR 864.5220) .The Classification Number is 81GKZ. Predicate Device(s) Sysmex™ w/IRF Parameter (K971736/S1), COULTER® GEN-S™ System (K962988), COULTER® New Methylene Blue Prep Retic MAXM/AL Analyzers (K925344) Description The Immature Reticulocyte Fraction expresses t…
Coulter Corp.19964
*K925344Coulter New Meth Blue Preprep Retic/Maxm W/Autoloa
Summary page 1
…Number is 81GKZ. Predicate Device(s) Sysmex™ w/IRF Parameter (K971736/S1), COULTER® GEN-S™ System (K962988), COULTER® New Methylene Blue Prep Retic MAXM/AL Analyzers (K925344) Description The Immature Reticulocyte Fraction expresses the number of early reticulocytes as a proportion of the total reticu…
Coulter Corp.1993—

Also cleared against K971736: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 12 years and passes through 2 companies; a new generation was cleared every 7.8 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • 1 other device also cites its predicate K971736.

How does its category compare?

All GKZ devices

GKZ Counter, Differential Cell: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GKZ

4in 2025

2007: 62008: 62009: 62010: 42011: 32012: 32013: 12014: 32015: 32016: 32017: 42018: 32019: 52020: 12022: 32023: 42024: 32025: 42026 (partial year): 4
2007high 6 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKZ

108in 2025

2007: 117 days median2008: 99 days median2009: 147 days median2010: 290 days median2011: 315 days median2012: 408 days median2014: 165 days median2015: 273 days median2016: 198 days median2017: 280 days median2018: 270 days median2019: 210 days median2022: 638 days median2023: 329 days median2024: 157 days median2025: 108 days median2026 (partial year): 254 days median
2007high 638 (2022) · low 99 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GKZ

1in 2025

2007: 372008: 52009: 132010: 272011: 282012: 72013: 62015: 32016: 32017: 32018: 2, 2 Class I2019: 22020: 12022: 42023: 12025: 1
2007high 37 (2007) · low 0 (2014)2026

Class I (2 since 2007) Class II/III not classified

Adverse event reports per year · GKZ

77in 2025

2007: 2682008: 9252009: 5592010: 8962011: 2,9052012: 2,9592013: 3,0702014: 3,1122015: 1,9722016: 3,3382017: 2292018: 4972019: 9082020: 3422021: 3912022: 1982023: 1552024: 1152025: 77
2007high 3,338 (2016) · low 77 (2025)2025

MAUDE reports naming product code GKZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611737268
20086995925
2009614713559
2010429027896
20113315282,905
2012340872,959
20131—63,070
2014316503,112
2015327331,972
2016319833,338
201742803229
201832702 (2)497
201952102908
20201—1342
20210—0391
202236384198
202343291155
202431570115
20254108177
202642540—

What is it indicated for?

The COULTER GEN-S System with IRF and MRV Parameters is a quantitative, automated hematology analyzer and leukocyte differential counter For In Vitro Diagnostic Use in clinical laboratories. The COULTER GEN-S System also provides automated Reticulocyte analysis.

An automated differential cell counter is a device used to identify and classify one or more of the formed elements of blood.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K993356: Coulter Hematology Analyzers with Irf & MRV Analyses.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K993356

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026