510(k) · Cleared
ClearedLiverpool Radial Head Replacement Device
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomet, Inc. · KWI Prosthesis, Elbow, Hemi-, Radial, Polymer
Cleared on Jan 30, 2002 as substantially equivalent to K984290 (Implex Corp., 1999) and 2 other predicates after a 176-day review. Its family tree reaches back 1 generation to 1999. 23 later devices descend from it.
- Decided
- Jan 30, 2002
- Review
- 176 days
- Class
- Class II
- Product code
- KWI
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 1 generation to K984290 (1999). 3 ancestors in all. 23 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK984290 Implex Radial Head Replacement SystemImplex Corp. · 1999
- This deviceK012551 Liverpool Radial Head Replacement DeviceBiomet, Inc. · 2002
- Descendant · cites it directly · 22 of its ownK040611 Modular Radial Head Replacement DeviceBiomet, Inc. · 2004 · Recalled
- Descendant · 2 generations on · 21 of its ownK051385 Explor Modular Radial Head Replacement DeviceBiomet, Inc. · 2005 · Recalled
- Descendant · 3 generations on · 18 of its ownK060438 RHSTornier · 2006
- Descendant · 3 generations on · 16 of its ownK130533 Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · Recalled
- Descendant · 4 generations on · 15 of its ownK153452 Salto XT, Salto TalarisTornier S.A.S. · 2016 · Recalled
Showing 5 of 23 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 23 · See all- K040611Modular Radial Head Replacement DeviceBiomet, Inc. · 2004 · cites it directly22descendants
- K051385Explor Modular Radial Head Replacement DeviceBiomet, Inc. · 2005 · 2 generations on21descendants
- K060438RHSTornier · 2006 · 3 generations on18descendants
- K130533Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · 3 generations on16descendants
- K153452Salto XT, Salto TalarisTornier S.A.S. · 2016 · 4 generations on15descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K984290 | Implex Radial Head Replacement System | Implex Corp. | 1999 | — |
| 0 (this device) | K012551 | Liverpool Radial Head Replacement Device | Biomet, Inc. | 2002 | — |
| +1 | K040611 | Modular Radial Head Replacement Device | Biomet, Inc. | 2004 | 1 |
| +2 | K051385 | Explor Modular Radial Head Replacement Device | Biomet, Inc. | 2005 | 2 |
| +3 | K060438 | RHS | Tornier | 2006 | — |
| +3 | K130533 | Salto Talaris Total Ankle Prosthesis, RHS | Tornier S.A.S. | 2013 | 19 |
| +4 | K153452 | Salto XT, Salto Talaris | Tornier S.A.S. | 2016 | 8 |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2004 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2010 | 2 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 3 | 0 |
| 2021 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 4 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWI device
- #1 K260624 Arthrex Radial Head Replacement Systemscore 12.1 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K984290 | Implex Radial Head Replacement SystemSummary page 1…l (hemi-elbow) polymer prosthesis (21 CFR 888.3170) Legally Marketed Devices to Which Substantial Equivalence Is Claimed: Radial Head Surface. Replacement (Implex Corp. K984290), Radial Head Impiant (Avanta Orthop., Inc., K002644) and Modular Radial Head (Wright Medical Tech. Inc,, K991915) P Davice Dosc… | 1999 |
| * | K002644 | Radial Head ImplantSummary page 1…Legally Marketed Devices to Which Substantial Equivalence Is Claimed: Radial Head Surface. Replacement (Implex Corp. K984290), Radial Head Impiant (Avanta Orthop., Inc., K002644) and Modular Radial Head (Wright Medical Tech. Inc,, K991915) P Davice Doscrlpf:lon; The Biomet Liverpool Radial Head Replacemen… | 2000 |
| * | K991915 | Modular Radial HeadSummary page 1…Claimed: Radial Head Surface. Replacement (Implex Corp. K984290), Radial Head Impiant (Avanta Orthop., Inc., K002644) and Modular Radial Head (Wright Medical Tech. Inc,, K991915) P Davice Doscrlpf:lon; The Biomet Liverpool Radial Head Replacement Device Is a one-piece cobalt alloy i prosthesis consisting.… | 1999 |
What descends from it? (23)
See all 231 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K040611 | Modular Radial Head Replacement Device | 2004 | 22 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All KWI devicesKWI Prosthesis, Elbow, Hemi-, Radial, Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWI
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · KWI
Too few KWI 510(k)s in any year since 2007 to give a median.
Recalls per year · KWI
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWI
118in 2025
MAUDE reports naming product code KWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 15 |
| 2008 | 0 | — | 0 | 16 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 1 | — | 0 | 13 |
| 2011 | 0 | — | 0 | 10 |
| 2012 | 1 | — | 0 | 16 |
| 2013 | 1 | — | 1 | 31 |
| 2014 | 1 | — | 1 | 29 |
| 2015 | 0 | — | 0 | 103 |
| 2016 | 0 | — | 0 | 138 |
| 2017 | 1 | — | 1 | 360 |
| 2018 | 0 | — | 0 | 202 |
| 2019 | 1 | — | 0 | 214 |
| 2020 | 1 | — | 0 | 118 |
| 2021 | 1 | — | 0 | 44 |
| 2022 | 1 | — | 2 | 44 |
| 2023 | 1 | — | 0 | 77 |
| 2024 | 1 | — | 0 | 124 |
| 2025 | 0 | — | 0 | 118 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The Liverpool Radial Head Replacement Device is intended for:
1) Replacement of the radial head for degenerative or post-traumatic disabilities
presenting pain, creptation, and decreased motion at the radio-humeral and/or
proximal radio-ulnar joint with:
a) Joint destruction and/or subluxation visible on x-ray
b) Resistance to conservative treatment
2) Primary replacement after fracture of the radial head
3) Symptomatic sequelae after radial head resection
4) Revision following failed radial head arthroplasty
The device is intended for single use with bone cement.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K012551 · printed Nov 6, 2026
Cite this page
510(k) Report. “K012551: Liverpool Radial Head Replacement Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K012551
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026