510(k) · Cleared
ClearedRHS
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Tornier · JDB Prosthesis, Elbow, Semi-Constrained, Cemented
Cleared on Apr 18, 2006 as substantially equivalent to K994041 (Tornier, Inc., 2000) and 2 other predicates after a 56-day review. Its family tree reaches back 4 generations to 1999. 18 later devices descend from it.
- Decided
- Apr 18, 2006
- Review
- 56 days
- Class
- Class II
- Product code
- JDB
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 4 generations to K984290 (1999). 10 ancestors in all, the oldest K944507 (1995). 18 later devices descend from it, 2 citing it directly.
- Root · 4 generations backK984290 Implex Radial Head Replacement SystemImplex Corp. · 1999
- 3 generations backK012551 Liverpool Radial Head Replacement DeviceBiomet, Inc. · 2002
- 2 generations backK040611 Modular Radial Head Replacement DeviceBiomet, Inc. · 2004 · Recalled
- 1 generation backK051385 Explor Modular Radial Head Replacement DeviceBiomet, Inc. · 2005 · Recalled
- This deviceK060438 RHSTornier · 2006
- Descendant · cites it directly · 16 of its ownK130533 Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · Recalled
- Descendant · 2 generations on · 15 of its ownK153452 Salto XT, Salto TalarisTornier S.A.S. · 2016 · Recalled
- Descendant · 3 generations on · 8 of its ownK192994 Paragon 28 APEX 3D Total Ankle Replacement SystemParagon 28, Inc. · 2020
- Descendant · 4 generations on · 2 of its ownK210390 Apex 3D Total Ankle Replacement SystemParagon 28, Inc. · 2021
- Descendant · 2 generations on · 2 of its ownK171004 Hintermann Series H2 Total Ankle SystemDt Medtech, LLC · 2017
Showing 5 of 18 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 18 · See all- K130533Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · cites it directly16descendants
- K153452Salto XT, Salto TalarisTornier S.A.S. · 2016 · 2 generations on15descendants
- K192994Paragon 28 APEX 3D Total Ankle Replacement SystemParagon 28, Inc. · 2020 · 3 generations on8descendants
- K210390Apex 3D Total Ankle Replacement SystemParagon 28, Inc. · 2021 · 4 generations on2descendants
- K171004Hintermann Series H2 Total Ankle SystemDt Medtech, LLC · 2017 · 2 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K984290 | Implex Radial Head Replacement System | Implex Corp. | 1999 | — |
| −3 | K012551 | Liverpool Radial Head Replacement Device | Biomet, Inc. | 2002 | — |
| −2 | K040611 | Modular Radial Head Replacement Device | Biomet, Inc. | 2004 | 1 |
| −1 | K051385 | Explor Modular Radial Head Replacement Device | Biomet, Inc. | 2005 | 2 |
| 0 (this device) | K060438 | RHS | Tornier | 2006 | — |
| +1 | K130533 | Salto Talaris Total Ankle Prosthesis, RHS | Tornier S.A.S. | 2013 | 19 |
| +2 | K153452 | Salto XT, Salto Talaris | Tornier S.A.S. | 2016 | 8 |
| +3 | K192994 | Paragon 28 APEX 3D Total Ankle Replacement System | Paragon 28, Inc. | 2020 | — |
| +4 | K210390 | Apex 3D Total Ankle Replacement System | Paragon 28, Inc. | 2021 | — |
| +2 | K171004 | Hintermann Series H2 Total Ankle System | Dt Medtech, LLC | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 2 | 0 |
| 2002 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2010 | 1 | 0 |
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 3 | 0 |
| 2021 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 4 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in JDB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new JDB device
- #1 K222807 TEMA Elbow system - Line extensionscore 4.0 · 7 generations · no Class I recall
- #2 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K994041 | Tornier Bipolar Radial Head ProsthesisSummary page 1…ice class: Class 11 Classification panel: Orthopedic Product code: JDB &KWI 5) Equivalent I Predicate device Radial Head Prosthesis, Tomier, K99404 1 Radial Head, Avanta, K023604 Explor, Biomet, K051385… | 2000 |
| * | K023604 | Modification to Radial Head ImplantSummary page 1…1 Classification panel: Orthopedic Product code: JDB &KWI 5) Equivalent I Predicate device Radial Head Prosthesis, Tomier, K99404 1 Radial Head, Avanta, K023604 Explor, Biomet, K051385 Page 1/… | 2002 |
| * | K051385 | Explor Modular Radial Head Replacement DeviceSummary page 1…Orthopedic Product code: JDB &KWI 5) Equivalent I Predicate device Radial Head Prosthesis, Tomier, K99404 1 Radial Head, Avanta, K023604 Explor, Biomet, K051385 Page 1/ page 2 TORNIER… | 2005 |
What descends from it? (18)
See all 182 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 3 companies; a new generation was cleared every 2.3 years on median.
- 6 of the 10 ancestors have a recall of any class.
- Of its descendants, K130533 (Tornier S.A.S., 2013) has gone furthest, with 16 descendants of its own.
- 1 other device also cites its predicate K994041.
How does its category compare?
All JDB devicesJDB Prosthesis, Elbow, Semi-Constrained, Cemented: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · JDB
1in 2022
2026 to Oct 25, outlined.
Median 510(k) review, days · JDB
Too few JDB 510(k)s in any year since 2007 to give a median.
Recalls per year · JDB
1in 2024
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · JDB
38in 2025
MAUDE reports naming product code JDB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 3 |
| 2008 | 0 | — | 0 | 13 |
| 2009 | 0 | — | 0 | 10 |
| 2010 | 2 | — | 0 | 7 |
| 2011 | 0 | — | 1 | 6 |
| 2012 | 0 | — | 0 | 6 |
| 2013 | 0 | — | 0 | 2 |
| 2014 | 0 | — | 0 | 5 |
| 2015 | 0 | — | 0 | 44 |
| 2016 | 0 | — | 0 | 11 |
| 2017 | 1 | — | 0 | 26 |
| 2018 | 1 | — | 0 | 39 |
| 2019 | 0 | — | 0 | 31 |
| 2020 | 1 | — | 0 | 32 |
| 2021 | 0 | — | 0 | 23 |
| 2022 | 1 | — | 0 | 58 |
| 2023 | 0 | — | 0 | 29 |
| 2024 | 0 | — | 1 | 163 |
| 2025 | 0 | — | 0 | 38 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The RHS is intended for:
1) Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation and decreased motion at the radio-humeral and/or proximal radio-ulnar joint with:
a. Joint destruction and/or subluxation visible on x-ray
b. Resistance to conservative treatment
2) Primary replacement after fracture of the radial head
3) Symptomatic sequelae after radial head resection
4) Revision following failed radial head arthroplasty
The long stem is for single cemented use only. The short stem coated with titanium plasma-spray is for single use with or without cement.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K060438 · printed Nov 4, 2026
Cite this page
510(k) Report. “K060438: RHS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K060438
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026