510(k) · Cleared
Recalled · Class II · 2017Explor Modular Radial Head Replacement Device
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Biomet, Inc. · KWI Prosthesis, Elbow, Hemi-, Radial, Polymer
Cleared on Aug 5, 2005 as substantially equivalent to K040611 (Biomet, Inc., 2004) and 3 other predicates after a 70-day review. Its family tree reaches back 3 generations to 1999. 21 later devices descend from it. It has been recalled 2 times.
- Decided
- Aug 5, 2005
- Review
- 70 days
- Class
- Class II
- Product code
- KWI
- Recalls
- 2
- Predicates
- 4
Its longest line of descent runs back 3 generations to K984290 (1999). 5 ancestors in all. 21 later devices descend from it, 4 citing it directly.
- Root · 3 generations backK984290 Implex Radial Head Replacement SystemImplex Corp. · 1999
- 2 generations backK012551 Liverpool Radial Head Replacement DeviceBiomet, Inc. · 2002
- 1 generation backK040611 Modular Radial Head Replacement DeviceBiomet, Inc. · 2004 · Recalled
- This deviceK051385 Explor Modular Radial Head Replacement DeviceBiomet, Inc. · 2005
- Descendant · cites it directly · 18 of its ownK060438 RHSTornier · 2006
- Descendant · cites it directly · 16 of its ownK130533 Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · Recalled
- Descendant · 2 generations on · 15 of its ownK153452 Salto XT, Salto TalarisTornier S.A.S. · 2016 · Recalled
- Descendant · 3 generations on · 8 of its ownK192994 Paragon 28 APEX 3D Total Ankle Replacement SystemParagon 28, Inc. · 2020
- Descendant · 4 generations on · 2 of its ownK210390 Apex 3D Total Ankle Replacement SystemParagon 28, Inc. · 2021
Showing 5 of 21 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 21 · See all- K060438RHSTornier · 2006 · cites it directly18descendants
- K130533Salto Talaris Total Ankle Prosthesis, RHSTornier S.A.S. · 2013 · cites it directly16descendants
- K153452Salto XT, Salto TalarisTornier S.A.S. · 2016 · 2 generations on15descendants
- K192994Paragon 28 APEX 3D Total Ankle Replacement SystemParagon 28, Inc. · 2020 · 3 generations on8descendants
- K210390Apex 3D Total Ankle Replacement SystemParagon 28, Inc. · 2021 · 4 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K984290 | Implex Radial Head Replacement System | Implex Corp. | 1999 | — |
| −2 | K012551 | Liverpool Radial Head Replacement Device | Biomet, Inc. | 2002 | — |
| −1 | K040611 | Modular Radial Head Replacement Device | Biomet, Inc. | 2004 | 1 |
| 0 (this device) | K051385 | Explor Modular Radial Head Replacement Device | Biomet, Inc. | 2005 | — |
| +1 | K060438 | RHS | Tornier | 2006 | — |
| +1 | K130533 | Salto Talaris Total Ankle Prosthesis, RHS | Tornier S.A.S. | 2013 | 19 |
| +2 | K153452 | Salto XT, Salto Talaris | Tornier S.A.S. | 2016 | 8 |
| +3 | K192994 | Paragon 28 APEX 3D Total Ankle Replacement System | Paragon 28, Inc. | 2020 | — |
| +4 | K210390 | Apex 3D Total Ankle Replacement System | Paragon 28, Inc. | 2021 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2006 | 1 | 0 |
| 2010 | 2 | 0 |
| 2012 | 1 | 0 |
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 1 | 0 |
| 2018 | 1 | 0 |
| 2020 | 3 | 0 |
| 2021 | 2 | 0 |
| 2022 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 4 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KWI device
- #1 K260624 Arthrex Radial Head Replacement Systemscore 12.1 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (4)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K040611 | Modular Radial Head Replacement DeviceSummary page 1…t radial (hemi-elbow) polymer prosthesis (21 CFR 888.3170) Legally Marketed Devices to Which Substantial Equivalence Is Claimed: Modular Radial Head Replacement Device (K04061 1), Radial Head Surface Replacement (Implex Corp. K984290), Radial Head Implant (Avanta Orthop., Inc., K002644) and Evolve Modular… | 2004 |
| * | K984290 | Implex Radial Head Replacement SystemSummary page 1…) Legally Marketed Devices to Which Substantial Equivalence Is Claimed: Modular Radial Head Replacement Device (K04061 1), Radial Head Surface Replacement (Implex Corp. K984290), Radial Head Implant (Avanta Orthop., Inc., K002644) and Evolve Modular Radial Head (Wright Medical Tech. Inc., K991915) Device… | 1999 |
| * | K002644 | Radial Head ImplantSummary page 1…valence Is Claimed: Modular Radial Head Replacement Device (K04061 1), Radial Head Surface Replacement (Implex Corp. K984290), Radial Head Implant (Avanta Orthop., Inc., K002644) and Evolve Modular Radial Head (Wright Medical Tech. Inc., K991915) Device Description: The ExploR TM Modular Radial Head Repla… | 2000 |
| * | K991915 | Modular Radial HeadSummary page 1…), Radial Head Surface Replacement (Implex Corp. K984290), Radial Head Implant (Avanta Orthop., Inc., K002644) and Evolve Modular Radial Head (Wright Medical Tech. Inc., K991915) Device Description: The ExploR TM Modular Radial Head Replacement Device is a two-piece cobalt alloy prosthesis consisting of a… | 1999 |
What descends from it? (21)
See all 214 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jun 16, 2017 | Class II | Z-0269-2018 | Packaging change control | Zimmer Biomet is conducting a medical device recall for the ExploR 6x24mm Implantable Stem with Screw due to a complaint alleging that the Modular Radial HD lock screw was not included in the package for the stem. |
| Apr 22, 2014 | Class II | Z-1615-2014 | Process control | This lot of the ExploR Modular Radial Stem may be missing the wedge ramp threads. If the wedge ramp threads are missing from the stem, the likelihood of the set screw loosening from the radial stem intraoperatively is increased. If the… |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 6 years and passes through 2 companies; a new generation was cleared every 2.3 years on median.
- 3 of the 5 ancestors have a recall of any class.
- Of its descendants, K060438 (Tornier, 2006) has gone furthest, with 18 descendants of its own.
How does its category compare?
All KWI devicesKWI Prosthesis, Elbow, Hemi-, Radial, Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years.
FDA decisions per year · KWI
1in 2024
2026 to Oct 25, outlined.
Median 510(k) review, days · KWI
Too few KWI 510(k)s in any year since 2007 to give a median.
Recalls per year · KWI
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KWI
118in 2025
MAUDE reports naming product code KWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 15 |
| 2008 | 0 | — | 0 | 16 |
| 2009 | 0 | — | 0 | 14 |
| 2010 | 1 | — | 0 | 13 |
| 2011 | 0 | — | 0 | 10 |
| 2012 | 1 | — | 0 | 16 |
| 2013 | 1 | — | 1 | 31 |
| 2014 | 1 | — | 1 | 29 |
| 2015 | 0 | — | 0 | 103 |
| 2016 | 0 | — | 0 | 138 |
| 2017 | 1 | — | 1 | 360 |
| 2018 | 0 | — | 0 | 202 |
| 2019 | 1 | — | 0 | 214 |
| 2020 | 1 | — | 0 | 118 |
| 2021 | 1 | — | 0 | 44 |
| 2022 | 1 | — | 2 | 44 |
| 2023 | 1 | — | 0 | 77 |
| 2024 | 1 | — | 0 | 124 |
| 2025 | 0 | — | 0 | 118 |
| 2026 | 1 | — | 0 | — |
What is it indicated for?
The ExploRTM Modular Radial Head Replacement Device is intended for:
1) Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at the radio-humeral and/or proximal radio-ulnar joint with:
a) Joint destruction and/or subluxation visible on x-ray
b) Resistance to conservative treatment
2) Primary replacement after fracture of the radial head
3) Symptomatic sequelae after radial head resection
4) Revision following failed radial head arthroplasty
The device is intended for single use with or without bone cement.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K051385 · printed Nov 5, 2026
Cite this page
510(k) Report. “K051385: Explor Modular Radial Head Replacement Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K051385
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026