510(k) Report

510(k) · Cleared

Cleared

Licox CC1.G2 Brain Oxygen Catheter-Microprobe

K020558510(k) SpecialCleared Mar 21, 200229-day reviewClass II21 CFR 882.1620

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Integra Neurosciences · GWM Device, Monitoring, Intracranial Pressure

Cleared on Mar 21, 2002 as substantially equivalent to K002765 (Integra Neurosciences, 2000) after a 29-day review. Its family tree reaches back 1 generation to 2000. 3 later devices descend from it.

Decided
Mar 21, 2002
Review
29 days
Class
Class II
Product code
GWM
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K002765 (2000). 3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2004: 1 descendant cleared2013: 1 descendant cleared2006: 1 descendant clearedK002765 · Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc Introducer Kits-IM,IM2,IM3,II1 Licoximc Tempe · Integra Neurosciences · 2000 · recalled200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants K002765 · Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc Introducer Kits-IM,IM2,IM3,II1 Licoximc Tempe · Integra Neurosciences · 2000 · recalled0
  1. Root · 1 generation backK002765 Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB…Integra Neurosciences · 2000 · Recalled
  2. This deviceK020558 Licox CC1.G2 Brain Oxygen Catheter-MicroprobeIntegra Neurosciences · 2002
  3. Descendant · cites it directly · 2 of its ownK040235 Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation · 2004 · Recalled
  4. Descendant · 2 generations on · 0 of its ownK131184 Integra Licox PTO2 MonitorIntegra Lifesciences Corp. · 2013 · Recalled
  5. Descendant · 2 generations on · 0 of its ownK053244 Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp. · 2006 · Recalled

Most influential descendants

Showing 3 of 3 · See all
  • K040235Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation · 2004 · cites it directly2descendants
  • K131184Integra Licox PTO2 MonitorIntegra Lifesciences Corp. · 2013 · 2 generations on0descendants
  • K053244Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp. · 2006 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K002765Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc…Integra Neurosciences20003
0 (this device)K020558Licox CC1.G2 Brain Oxygen Catheter-MicroprobeIntegra Neurosciences2002—
+1K040235Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation200412
+2K131184Integra Licox PTO2 MonitorIntegra Lifesciences Corp.20135
+2K053244Licox IT2 Complete Brain Tunneling Probe KitIntegra Lifesciences Corp.20061

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200410
200610
201310
FIG. 1 — Lineage of K020558, 2000–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWM device

  1. #1 K252241 Pressio 3 Multi-parameter Neuromonitoring Systemscore 12.9 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002765Licox CMP Monitor-AC3.1, Licox Imc Oxygen Catheters-CC1,CC1.SB Luicox Imc Introducer…
Summary page 1
…® CC1.G2 product was designed to have the same indications for use and perform to the same specifications as the LICOX® CC1.SB Brain Oxygen Catheter- Microprobe (510(k) K002765). Device Description: The LICOX® CC1.G2 is a brain oxygen catheter-microprobe intended for use with the LICOX Brain Oxygen Moni…
Integra Neurosciences20003

Also cleared against K002765: 8 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K040235Licox Pmo Brain Monitoring SystemIntegra LifeSciences Corporation20042

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • Of its descendants, K040235 (Integra LifeSciences Corporation, 2004) has gone furthest, with 2 descendants of its own.
  • 8 other devices also cite its predicate K002765.

How does its category compare?

All GWM devices

GWM Device, Monitoring, Intracranial Pressure: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · GWM

1in 2025

2007: 22008: 22009: 12010: 22011: 32012: 42013: 22014: 22016: 32017: 32018: 12019: 22020: 32021: 22024: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWM

30in 2020

2011: 123 days median2012: 100 days median2016: 192 days median2017: 37 days median2020: 30 days median
2007high 192 (2016) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWM

3in 2025

2008: 12010: 92011: 62012: 12013: 122014: 22019: 12023: 1, 1 Class I2024: 4, 2 Class I2025: 3
2007high 12 (2013) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · GWM

441in 2025

2007: 1262008: 1052009: 1172010: 1042011: 1842012: 1512013: 1202014: 3602015: 4862016: 4192017: 4452018: 3022019: 2602020: 2682021: 2112022: 4242023: 7442024: 6412025: 441
2007high 744 (2023) · low 104 (2010)2025

MAUDE reports naming product code GWM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—0126
20082—1105
20091—0117
20102—9104
201131236184
201241001151
20132—12120
20142—2360
20150—0486
201631920419
20173370445
20181—0302
20192—1260
20203300268
20212—0211
20220—0424
20230—1 (1)744
20242—4 (2)641
20251—3441
20261—0—

What is it indicated for?

The LICOX® CC1.G2 is a brain oxygen catheter-microprobe intended for use with the LICOX Brain Oxygen Monitoring System. The LICOX Brain Oxygen Monitoring System measures intracranial oxygen and temperature and is intended as an adjunct monitor of trends of these parameters, indicating the perfusion status of cerebral tissue local to sensor placement. LICOX System values are relative within an individual, and should not be used as the sole basis for decisions as to diagnosis or therapy. It is intended to provide data additional to that obtained by current clinical practice in cases where hypoxia or ischemia are a concern.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K020558: Licox CC1.G2 Brain Oxygen Catheter-Microprobe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K020558

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026